1-866-4 JJSTECH(1-866-455-7832)

Fieldpiece Dual Display Mini Clamp Meter - SC53

Item #:
FP-SC53
Brand:
Fieldpiece
Fieldpiece Dual Display Mini Clamp Meter - SC53
$115.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Fieldpiece Dual Display Mini Clamp Meter - SC53

Fieldpiece Dual Display Mini Clamp Meter - SC53

$115.00

Discontinued


SC53 Dual Display Mini Clamp Meter by Fieldpiece

Read amps and volts at the same time with the Dual-Display Mini Clamp Meter with Temperature, model SC53. In addition to having a dedicated display for reading amps, you can measure any of the other ranges on the meter dial simultaneously. The SC53 is compact measuring only about 8-inches, easy to use and includes many of the ranges you use everyday during HVACR field service. Many instructors recommend the SC53 as a starter meter while seasoned veterans call it a little HVAC workhorse. Temperature and capacitance, built-in safety features like non-contact voltage and amp or dial hold, make this meter a solid choice for the work you do in the field.

  • Dual Display
  • Temperature up to 400 degrees F
  • Capacitance (MFD)
  • 400AAC
  • Non-contact Voltage
  • Hold
  • Backlight
  • Volts AC
  • Volts DC
  • Resistance (Ohms)
  • Continuity
  • Rugged ABS case
  • Ergonomic shape
  • Auto power-off
  • Amps and volts simultaneously
  • Works with Fieldpiece Accessory Heads

Includes

  • Dual-Display Mini Clamp Meter with Temperature - SC53
  • Vinyl Test Leads
  • Mini Clamp-On Meter Case - ANC4
  • Three 3V lithium-ion CR2032 Batteries (installed)
  • Operator's Manual
General Specification
Display 33/4 digit liquid crystal (LCD) with a maximum reading of 3999
Overrange "OL" or “-OL” mark indication.
Auto power off 10 minutes.
Operating environment 32 to 122°F (0 to 50°C), at <70% R.H.
Storage temperature -4 to 140°F (-20 to 60°C), @ <80% R.H. with batteries removed.
Accuracy Specifications good in ambient conditions of 74°F ±8°F (23°C ±4°C), <75% relative humidity.
Temperature coefficient 0.1×(specified accuracy) per °F/°C; 32 to 66°F (0 to 19°C); 82 to 122°F(28 to 50°C). Altitude: 6561.7 feet (2000m).
Jaw opening capability 30mm (diameter) conductor
Power Three lithium-ion CR2032 3V batteries.
Battery life 100 hours typical for lithium-ion on AAC (top display),75 hours typical for lithium-ion on dial functions (bottom display).
Accessories One pair vinyl test leads, ATB1 k-type thermocouple (SC53), (3) 3V CR2032 batteries (installed), ANC4 carrying case, and operating instructions.
Safety IEC/EN 61010-1 (UL61010-1) CATIII 600V and IEC/EN 61010-2-032 (UL61010-2-032) CATIII 300V, class II and pollution degree 2 indoor use comply with CE, C-tick certified.
DC Volts
Ranges 4V, 40V, 400V, 600V
Resolution 1mV
Accuracy ±(0.5% rdg + 2 dgts)
Input impedance 4V: 10MΩ
40V~600V: 9.1MΩ
AC Volts (50Hz - 500Hz)
Ranges : 4V, 40V, 400V, 600V
Resolution 1mV
Accuracy ±(1.2% rdg + 5 dgts), ±(1.5% rdg + 5 dgts) on 600V range
Input impedance 4V: 10MΩ
40V~600V: 9.1MΩ
Minimum test time for stable reading 2 seconds
Resistance
Ranges 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
Resolution 0.1Ω
Accuracy ±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges
±(1.5% rdg + 4 dgts) on 4MΩ range
±(3.0% rdg + 5 dgts) on 40MΩ range
Open circuit volts -0.45VDC typical, (-1.2VDC on 400Ω range)
Minimum test time for stable reading 2 seconds
AC Current (50Hz - 60Hz)
Ranges 40A, 400A
Resolution 0.01A
Accuracy ±(2.0% rdg + 6 dgts)
DC Current (SC52)
Ranges 400μA, 4000μA
Resolution 0.1μA
Accuracy ±(1.0% rdg + 2 dgts)
Voltage burden 1V (8V on 4000μA range)
Capacitance (SC53)
Range 4μF, 40μF, 400μF, 4mF
4.000mF = 4000μF
Resolution 1.0nF
Accuracy ±(3% rdg + 10 dgts) on 4μF
±(3% rdg + 5 dgts) on 40μF to 400μF
±(5% rdg + 20 dgts) on 4mF (4000μF)
Minimum input range >100nF
Safety "dsc" symbol on LCD indicates that the capacitor must be discharged before testing
Continuity
Range 400Ω
Resolution
Audible indication Less than 25Ω
Response time 500ms
Diode Test (SC52)
Test current 1.2mA (approximate)
Accuracy ±(3.0% rdg + 3 dgts)
Resolution 10mV
Audible indication Less than 0.25V
Open circuit volts 3.0VDC typical
Temperature (SC53)
Range -30 to 400°F (-34 to 204°C)
Resolution 0.1°
Accuracy ±1°F (32 to 120°F); ±0.5°C (0 to 49°C),
±1% + 1.5°F (-4 to 400°F); ±1% + 1°C (-20 to 204°C),
±2% + 4°F (-30 to -4°F); ±2% + 2°C (-34 to -20°C)
Sensor type K-type thermocouple

Questions & Answers


There are no questions or answers for this item.