1-866-4 JJSTECH(1-866-455-7832)

Hanna Checker®HC Handheld Colorimeter - Total Chlorine Ultra-Low Range - HI761

Item #:
HI761
Brand:
Hanna Instruments
Hanna Checker®HC Handheld Colorimeter - Total Chlorine Ultra-Low Range - HI761
$62.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Checker®HC Handheld Colorimeter - Total Chlorine Ultra-Low Range - HI761

Hanna Checker®HC Handheld Colorimeter - Total Chlorine Ultra-Low Range - HI761

$62.00

Discontinued


HI761 Checker®HC Handheld Colorimeter - Total Chlorine Ultra-Low Range by Hanna Instruments

The HI 761 Checker®HC is a simple, accurate, and cost effective way to measure ultra-low ranges of total chlorine. Designed as a more accurate alternative to chemical test kits, the HI 761 provides quick, accurate results in four easy steps.

1.) Step One - Add a sample to the included cuvette(s)
2.) Step Two - Insert sample into the Checker and zero it out
3.) Step Three - Remove sample and add reagent
4.) Step Four - Reinsert sample and click the button to measure your results or… - Press and hold the button for 3 seconds for a time reaction reading

The HI 761 uses an adaptation of the USEPA method 330.5. The reaction between the chlorine and DPD reagent causes a pink tint in the sample.

Features/Benefits:

  • Small palm-sized design
  • Accurate from ±5ppb ± 5% of reading
  • Dedicated to a single parameter
  • Uses a single AAA battery
  • Auto Power Off after 10 minutes in inactivity
  • Built-in timer for timed reaction readings

Primary Applications:

  • Water Quality
  • Education
  • Water Purification
  • Environmental

Order Information:

The HI 761 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets for total chlorine ultra-low range), 1 x 1.5V AAA battery, and an instruction manual.

Range 0 to 500 ppb
Resolution 1 ppb
Accuracy (@25°C/77°F) ±5ppb ± 5% of reading
Measurement Method Colorimetric
Light Source Photodiode @525 nm
Light Detector Silicon photocell
Method Adaptation of the USEPA method 330.5. The reaction between the chlorine and DPD reagent causes a pink tint in the sample.
Power Supply Battery - 1 x 1.5V AAA
Power Auto Off After 10 min. of inactivity
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)