RAE Systems AutoRAE Lite Automated Test and Calibration Station for ToxiRAE 3 - T01-0100-000

Item #:
RAE-T01-0100-000
Brand:
RAE Systems
RAE Systems AutoRAE Lite Automated Test and Calibration Station for ToxiRAE 3 - T01-0100-000
$2,423.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RAE Systems AutoRAE Lite Automated Test and Calibration Station for ToxiRAE 3 - T01-0100-000

RAE Systems AutoRAE Lite Automated Test and Calibration Station for ToxiRAE 3 - T01-0100-000

$2,423.00

T01-0100-000 AutoRAE Lite Automated Test and Calibration Station for ToxiRAE 3 by RAE Systems

The AutoRAE Lite high-speed, low-operating-cost bump test and calibration station stores data in a text file that can be opened by any spreadsheet or editor. Providing the lowest cost of ownership, the AutoRAE Lite allows you to bump test 700 monitors on one set of batteries.

In addition, the AutoRAE Lite operates on a low-pressure system with a built-in pump.

AutoRAE Lite includes

  • AutoRAE Lite as specified
  • USB cable for PC set up
  • 12-volt power supply
  • Demand-flow regulator (installed)
  • SD memory card 512MB
  • Quick-start guide
  • Inlet filter
  • CD includes: Operation manual, Drivers, Utility software

Key Features

  • Fully automated bump and calibration
  • Bump test in 12 seconds
  • Full calibration in 2 minutes
  • Gas usage only 70 cm3 per bump test
  • Tamper-proof data files
  • Configures monitor
  • "No gas flow" alarm
  • Hidden tubing
  • Demand-flow system with included regulator

Applications

  • Emergency response
  • Environmental
  • Fire service
  • Industrial safety
  • Oil and gas
Certifications CE
Sensor Light and sound sensors to test instrument alarms
Data Storage Text files (format can be opened by any spreadsheet or editor), saved daily for:
1. Bump test
2. Calibrations
3. Alarms
4. Tamper-proof
Bump Test Time 12 sec
Bump Test Gas Usage 70 cm3
Calibration Time 2 min
Calibration Gas Usage 300 cm3
Pneumatic System Demand-flow regulator
Built-in pump
"No gas flow" alarm
Power Supply 12 VDC or battery pack
Battery Runtime 700 bump tests on 4 C size batteries
Operating Temperature +14° F to +122° F (-10° C to +50° C)
Humidity 10% to 90% relative humidity, non-condensing
Dimensions 15" L x 12.5" W x 6.5" H (38cm x 32cm x 17cm)
Weight 9 lbs (4.1 kg)