1-866-4 JJSTECH(1-866-455-7832)

Draeger X-am 5000 Multi-Gas Detector, LEL, O2, CO-H2Comp, H2, Rechargeable Kit - VN00117

Item #:
DR-VN00117
Brand:
Draeger
$2,773.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Draeger X-am 5000 Multi-Gas Detector, LEL, O2, CO-H2Comp, H2, Rechargeable Kit - VN00117

Draeger X-am 5000 Multi-Gas Detector, LEL, O2, CO-H2Comp, H2, Rechargeable Kit - VN00117

$2,773.00

VN00117 X-am 5000 Multi-Gas Detector, LEL, O2, CO-H2Comp, H2, Rechargeable Kit by Draeger

The Draeger X-am® 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures combustible gases and vapors as well as O2 and harmful concentrations of toxic gases, organic vapors, odorant and amine.

Ergonomic mobile phone design

Despite its advanced functionality, the Draeger X-am® 5000's practical mobile phone design and light-weight make it comfortable to carry. Reduced to its essentials, the two-button control panel and easy-to-follow menu allow for intuitive use.

Flexible sensor exchange

It is easy to exchange, upgrade, or calibrate the sensors to other gases. The ability to customize the Draeger X-am® 5000's sensors makes more applications possible including the possibility to deploy in a rental fleet.

Poison-resistant Ex sensor

For improved safety when facing unknown and potentially explosive hazards—the Draeger X-am® 5000 provides dependable warnings in the event of explosive atmospheres due to the high level of sensitivity of the innovative catalytic ex sensor. It not only responds quickly to explosive gases and combustible organic vapors, it is also highly resistant against sensor poisons such as silicone and hydrogen sulfide. In combination with its long-term stability, this offers an extraordinarily long sensor lifetime of over four years. This will reduce operational costs.

Durable sensor technology

Equipped with durable XXS sensor technology, the Draeger X-am® 5000 offers maximum security at extremely low operational costs. The sensor's resistance, in combination with its long-term stability, provides the sensor with a lifetime in excess of four years, which can help reduce operational costs.

Robust and watertight

The Draeger X-am® 5000 is water and dust resistant, according to IP67 standards. The detector remains fully functional and ready for use, even after being dropped into water. The integrated rubber protection and shockproof sensors provide additional resistance to impact and vibration. Moreover, the Draeger X-am® 5000 is resistant to electromagnetic interference.

External pump

The optional external pump, which operates with a hose length of up to 45 meters (147 feet) long for the Mark II pump, makes it possible to use the detector for pre-entry measurements into confined spaces such as tanks, shafts, etc. The pump starts automatically when attached to the gas detector.

Area monitoring

In combination with the Draeger X-zone® 5500, the gas detector can be used for various area monitoring applications. Up to 25 Draeger X-zone® 5500 units can be automatically interconnected to form a wireless fence line. This interconnection of the area monitoring devices allow for the fast securing of larger areas, e.g. pipelines or industrial tanks—even within the scope of industrial shutdowns.

Optimum solutions for function or bump tests and calibrations

Simple, fast, and professional: from a function or bump test to complete documentation, users can choose from a range of practical, on-site solutions that offer maximum safety for every application. The automatic test and calibration station Draeger X-dock® and the Draeger Bump Test Station are ideal system extensions that save time and reduce workload. Fresh air, mixed gas and single gas calibrations can be done directly using the Draeger X-am® 5000 menu.

Flexible power supply

The Draeger X-am® 5000 can be used with the standard alkaline batteries. In addition, it can be fitted with a T4 battery that can be charged while still inside the instrument. The optional Save Energy Mode makes it possible to increase the operating time of the Draeger X-am® 5000 to more than 40 hours. This is done by selecting a measurement interval of either one second (the standard), 10 or 20 seconds for the CatEx sensor.

Dimensions (W x H x D) 48 x 130 x 44 mm; 1.89 x 5.12 x 1.73 in.
Weight 220 – 250 g; 7.8 – 8.8 oz.
Ambient conditions Temperature: -20 – +50 °C; -4 – 122 °F
Pressure: 700 – 1,300 hPa
Humidity: 10 – 95% r.h.
Alarms Visual: 360°
Audible: Multi-tone > 90 dB at 30 cm
Ingress Protection IP67
Operating time > 12 hours with Alkaline and NiMH;
> 13 hours with NiMH HC; without Ex Sensor typ.
> 250 hours with Alkaline Battery; when using the Save Energy Mode
> 40 hours
Charging time < 4 hours
Data logger Can be read out via Infrared > 1,000 hours with 5 gases and a recording interval of 1 value per minute
Pump operation Maximum hose length 45 m; 147 ft.
Approvals ATEX: I M1 Ex da ia I Ma, II 1G Ex da ia IIC T4/T3 Ga
IECEx: IECExEx da ia I Ma, Ex da ia IIC T4/T3 Ga
c CSA us: Class I Div. 1 Group A, B, C, D, E, F, G T.-Code T4/T3, A/Ex da ia IIC T4/T3 /Ga
CE-mark: Electromagnetic compatibility Directive 2004 / 108 / EG; EN 50270:2006
EAC: PO Ex ia I X 0 Ex ia IIC T4 / T3 X
MED: Marine Equipment Directive 96 / 98 / EC

Questions & Answers