1-866-4 JJSTECH(1-866-455-7832)

Milwaukee Combined Logging, GLP, EC/TDS/NaCl/Temp Combined Data Logging Bench Meter - MW170US

Item #:
MW-MW170US
Brand:
Milwaukee
$665.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Milwaukee Combined Logging, GLP, EC/TDS/NaCl/Temp Combined Data Logging Bench Meter - MW170US

Milwaukee Combined Logging, GLP, EC/TDS/NaCl/Temp Combined Data Logging Bench Meter - MW170US

$665.00

MW170US Combined Logging, GLP, EC/TDS/NaCl/Temp Combined Data Logging Bench Meter by Milwaukee

The Milwaukee MW170 4-in-1 MAX EC/TDS/NaCl/Temp. Logging Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design and small benchtop footprint. It is accurate to ± 1% of reading for EC/TDS & Salinity with automatic, manual or no temperature compensation and a built in dedicated GLP key. Ideal for use by education, horticulture, labs, food processing, water treatment and many other applications with challenging EC/TDS/NaCL/Temp. measurement needs.

WHAT PEOPLE ARE SAYING

  • "Amazingly accurate, the best meter I have used so far."
  • "Very satisfied, very accurate, rugged device that calibrates easily."
  • "Rarely needs to be calibrated and gives perfect readings every time."
  • "Killer tool, good value."
  • "Logging data is easy-to-use and download"
  • "Love the GLP function"
  • "Logging functions increase the reliability of the data"
  • "Easy to Clean"

SUMMARY

The Milwaukee MW170 4-in-1 MAX EC/TDS/NaCl/Temp Bench Logging Meter is preferred by people testing samples in various applications. The easy-to-use logging feature allows data collection without messy notes and errors. From aquaculture, environmental, research to educators, the MW170 MAX is your meter for fast, accurate readings.

The Milwaukee MW170 MAX EC/TDS/NaCl/Temp. Bench meter offers:

ACCURACY

People choose the MW170 4-in-1 MAX EC/TDS/NaCl/Temp Bench Logging Meter to improve the accuracy of their testing program. With easy 1 point EC calibration, 6 standard buffer choices and 2 point temperature calibration, the meter can be quickly calibrated to a higher temperature accuracy compared to other meters and it provides more accurate temperature compensation readings than a one point calibration. The MW170 MAX Bench Meter is accurate to ± 1% of reading for EC/TDS and NaCL.

The meter comes with MA814DB/1 (4 ring) conductivity probe with a built in temperature sensor allowing the meter to automatically adjust the EC/TDS/NaCl reading for the effect of temperature (ATC).

The meter can also be used as a very accurate thermometer with accuracy +/-0.5°C (+/-0.9°F)

TOUGHNESS

The rugged meter is built to take knocks and has a sleek design that includes a small benchtop footprint.

LOW MAINTENACE

The MW170 MAX EC/TDS/NaCl/Temp Bench Logging Meter comes with the Milwaukee MA814DB/1 combination EC/Temp sensor. This is Milwaukee's top selling lab grade EC probe for a reason. Designed to be both low maintenance and able to withstand more challenging samples. The MA814DB/1 is ideal for use in horticulture, aquaculture, environmental labs, water treatment/conditioning and many other applications.

DESIGN FEATURES

  • Fast easy to read results with large duel level digital LCD readout.
  • Extreme accuracy to 1% of reading for EC/TDS/NaCl |+/- 0.5°C (+/-0.9°F).
  • Extended auto-ranging feature for EC/TDS/NaCl.
  • Lightweight, sleek design featuring a small benchtop footprint.
  • Simple easy-to-use logging; manual log-on-demand or manual log-on-stability up to 1,000 records.
  • Micro USB Port download functions.
  • GLP data, date and time.
  • Easy measurement: just place the probe in the sample, gently stir and wait for the reading to stabilize.
  • Single cell factor calibration for EC/TDS/NaCl, automatic simple one point calibration and two point for temperature allowing increased accuracy.
  • Rugged low maintenance, high performance, easy-to-clean EC/TDS/NaCL/Temp probe.
  • Built in temperature sensor.
  • Internal clock date to keep track of different time-dependent functions (calibration, timestamp,calibration time out).
  • 3 feet probe cables for extra flexibility when testing.
  • Includes MA9315 electrode holder, cables, adapter and probe.

CARE, USE AND CLEANING

EC meters usually start performing poorly because of problems with the sediment on the conductivity probe's rings. The dirty rings on the probe can change impedance. Cleaning the rings is simple. Slide the plastic shield off and clean with DI water and soft cloth to keep your readings accurate.

STORAGE

When not in use, store the meter and probe in a safe area to avoid damage. The EC probe is stored dry.

REFERENCE JUNCTION

The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH electrode will no longer function.

You can extend the life of your pH electrode in the following ways.

CLEANING AND STORAGE

All pH/ORP sensors have a limited life and response time gets longer with age. Properly maintaining your pH/ORP electrode will give you fast, accurate results for longer. So, be sure to order the Milwaukee Maitenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!

STORAGE

To minimize clogging the pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

Storing in pH probe storage solution MA9015 or pH calibration buffers will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe.

The best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

CALIBRATION

The MW170 MAX is easy 1 point EC/TDS/NaCl calibration for ease-of-use and two point temperature calibration for best accuracy in (ATC). Calibrating regularly is best to keep your PRO MW170 4-in-1 MAX Bench meter accurate for all your readings.

EC Range: 0.00 to 29.99 μS/cm / 30.0 to 299.9 μS/cm
EC Range: 300 to 2999 μS/cm
EC Range: 3.00 to 29.99 mS/cm / 30.0 to 200.0 mS/cm
EC Range: up to 500 mS/cm absolute conductivity
TDS Range: 0.00 to 14.99 ppm (mg/L)
TDS Range: 15.0 to 149.9 ppm (mg/L) / 150 to 1499 ppm (mg/L)
TDS Range: 1.50 to 14.99 g/L / 15.0 to 100.0 g/l
TDS Range: upt to 250.0 g/L absolute TDS
TDS Range: up to 400 g/L absolute TDS (with 0.80 factor)
Salinity Range: 0.0 to 400.0% NaCl / 2.00 to 42.00 PSU
Salinity Range: 0.00 to 80.00 g/L
Temp. Range: -20.0 to 120.00°C (-4.0 to 248.0°F)
EC Resolution: 0.01 μS/cm / 0.1 μS/cm / 1 μS/cm
EC Resolution: 0.01 mS/cm / 0.1 mS/cm
TDS Resolution: 0.01 ppm / 0.1 ppm / 1 ppm
TDS Resolution: 0.01 g/L / 0.1 g/L
Salinity Resolution: 0.1% NaCl / 0.01 PSU / 0.01 g/L
Temperature Resolution: 0.1°C / 0.1°F)
Accuracy: @ 25°C / 77°F
EC: ± 1% of reading / ±0.05 uS/cm or 1 digit, whichever is greater
TDS: ±1% of reading / ±0.03 ppm or 1 digit, whichever is greater
Salinity: ±1% of reading
Temperature: ±0.5°C (±0.9°F)
EC/TDS: single cell factor calibration, 6 standards: 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm / one point offset: 0.00 uS/cm
Salinity: one point with MA9066 salinity calibration solution
Temperature Compensation: Automatic or manual from -20 to 120°C (-4.0 to 248.0°F) or NO TC without temperature compensation
Conductivity temperature coefficient: 0.00 to 6.00 % / °C (EC and TDS only) | Default value: 1.90 % / °C
TDS factor: 0.40 to 0.80
Default value: 0.50
EC Probe: MA814DB/1 4 ring
Temperature probe: Built-in temperature sensor
Logging: Maximum 1,000 log records (stored in up to 100 lots) / on demand, 200 logs on stability, 200 logs, interval logging 1000
PC Connectivity: 1 micro USB port
Power Supply: 12 VDC adapter (included)
Battery Type: Internal
Battery life: Approx. 8 hours of use
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Dimensions: 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)
Weight: 0.9 kg / 2.00 lbs.
Warranty: 3 years meter

Datasheets & User Manuals

Questions & Answers