Quantrol Advantage MegaTron XS Tower Controllers with 4-20 Inputs for PYXIS PTSA, Conductivity, pH, 3 Timers, Flow Switch, Internet - XSCPF3E-HN4

Item #:
XSCPF3E-HN4
Brand:
Quantrol
Quantrol Advantage MegaTron XS Tower Controllers with 4-20 Inputs for PYXIS PTSA, Conductivity, pH, 3 Timers, Flow Switch, Internet - XSCPF3E-HN4
$4,160.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Quantrol Advantage MegaTron XS Tower Controllers with 4-20 Inputs for PYXIS PTSA, Conductivity, pH, 3 Timers, Flow Switch, Internet - XSCPF3E-HN4

Quantrol Advantage MegaTron XS Tower Controllers with 4-20 Inputs for PYXIS PTSA, Conductivity, pH, 3 Timers, Flow Switch, Internet - XSCPF3E-HN4

$4,160.00

XSCPF3E-HN4 Advantage MegaTron XS Tower Controllers with 4-20 Inputs for PYXIS PTSA, Conductivity, pH, 3 Timers, Flow Switch, Internet by Quantrol

Features

  • Cycles control with the make-up conductivity
  • Display mA readings in the System RUN screen
  • Auxiliary flowmeter inputs can activate a pulse timer
  • ORP has two set points with the second linked to a 28-day timer for shocking to a higher ORP value
  • USB downloaded history can be uploaded to WebAdvantage
  • Web communications to WebAdvantage via the customer's internal network or external cell router and data service
  • Four or eight mA inputs are available for specialty sensors, including PTSA trace, pressure, drum level, free chlorine and many other sensors
  • Force a relay into a single event defined time to catch up on chemical feed
  • Supports Bacnet, Modbus or Lonworks building management communications
  • Receive alarm from an auxiliary flowmeter if bleed is not occurring correctly
  • Biocide timers can remember to feed one event when flow comes back on if one or more feed events are missed during no flow conditions
  • Second conductivity set point for no inhibitor conditions is available
  • Tower conductivity, make-up conductivity, pH and ORP in one unit
  • Pulse timers can have two different water meter inputs added together for the accumulate activation setting
  • Chemical feed can be interrupted during bleed or other events
  • Five miscellaneous digital inputs from drum level wands
  • Advanced relay logic for special controlling schemes
  • Pulse timer initiated boiler conductivity sampling
  • Single or dual boiler conductivity control