1-866-4 JJSTECH(1-866-455-7832)

Draeger X-am 8000 Multi-Gas Detector, Basic, Pump - 8325875

Item #:
DR-8325875
Brand:
Draeger
$2,254.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Draeger X-am 8000 Multi-Gas Detector, Basic, Pump - 8325875

Draeger X-am 8000 Multi-Gas Detector, Basic, Pump - 8325875

$2,254.00

8325875 X-am 8000 Multi-Gas Detector, Basic, Pump by Draeger

Clearance measurement was never this easy and convenient: The 1 to 7 gas detector detects toxic and flammable gases as well as vapors and oxygen all at once – either in pump or diffusion mode. Innovative signaling design and handy assistant functions ensure complete safety throughout the process.

Multi-gas detector

  • 1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapors and oxygen

Specially designed for use with a pump, optimized for clearance measurement

The Draeger X-am® 8000 is equipped with a very powerful pump. It can be connected with hoses of up to 45 meters in length. A pump adapter makes it easy to switch between diffusion and pump mode at any time. This means the pump is only operated when you actually need it. That saves energy, reduces wear and tear, and extends the lifespan of the pump.

Handy and durable, the Draeger X-am® 8000 is intuitive to operate single-handedly using three function keys. The easy-to-read color display clearly lays out all the information for you.

The multi-gas detector also features advanced software functions including change of measurement gas for PID, CatEx and IR sensor during operation. This is based on an on-board library and a convenient assistant to hide unused sensor channels and adapt the flexible instrument to the measurement task.

Standard accessories include a sturdy shoulder strap so you can comfortably carry the X-am 8000. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.

Clearance measurement, release and documentation in no time

The X-am 8000 effectively supports various applications with specially developed assistant functions that guide you through each process step by step. During clearance measurement, for example, the smart assistant calculates the necessary flooding time for the device and probe (FKM hose) based on parameters such as measuring gases, temperature limits, and the indicated hose length. Additionally, customer defined flooding times are also possible.

When monitoring for potentially high methane concentrations, an optional automatic measurement range switch makes it easier to take a reading: If the Cat-Ex sensor measures values above 100 % LEL, the display switches to the range of 0 to 100 vol %. A similar function to measure in % LEL and vol % simultaneously is also available for the IR EX ES sensor.

The DraegerSensor CatEx 125 PR Gas offers a special variant for the measuring gas methane, which enables measurements in the ppm range. The performance of selected sensors has been verified by an external approval body within the scope of the measurement performance approval (EN 60079-29-1) for combustible gases and vapors including methane, propane and n-nonane.

An additional useful tool is CSE Connect. It combines an app, specially designed for the X-am 8000, with a cloud-computing solution. Measuring jobs can be quickly and easily transferred to the app using an online application. An optional Bluetooth® module in the Draeger X-am 8000 enables measured values to be transferred automatically to the CSE Connect app. You can also easily and conveniently use the app to create measurement reports. This saves time and helps you manage your measuring tasks during clearance measurements more efficiently.

Clear signaling design

The signal system of the Draeger X-am 8000 is based on a clear color code, in accordance with the requirements of EN 60079-29-1, EN 45544-1 and EN 50104:

  • Red light = gas alarm
  • Yellow light = device-related alarm, e.g. low battery
  • Green light = device is ready for use

The green glow of the D-Light allows you to see from a distance whether the device has been properly tested and is ready for use.

In case of an alarm, the X-am 8000 alerts you with colorful warning LEDs, a loud horn (100 dB(A) at a distance of 30 cm), and clearly palpable vibration. Optionally, four preset hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows the user to easily recognize the type of hazard based purely on the symbol displayed.

The X-am 8000 is equipped with an impact detection system. The event report indicates whenever severe mechanical impacts have occurred that might result in functional impairments of the device or the sensors. These are also documented in the data logger. With this information, a device operator can specifically check the device. The instrument can also be locked after a detected impact as well.

Economical Fleet Management

Bumptest and calibration are carried out simply and quickly using the Draeger X-dock® calibrating station. Its low test gas consumption keeps operating costs to a minimum.

Its reporting function and numerous other useful features make the X-dock Manager PC software a smart addition to any fleet management operation. To identify devices in your fleet, you can either use tried and tested barcodes or an integrated RFID transponder.

Specialist for high and low hydrocarbon concentrations

To measure hard-to-detect hydrocarbons, you can fit the Draeger X-am 8000 with one of two high-performance PID sensors. The PID HC covers a measurement range of 0 to 2,000 ppm (isobutene). The PID LC ppb is particularly suited for a measurement range of 0 to 10 ppm (isobutene) with a high resolution in the range below 1 ppm.

For benzene-specific measurements, the X-am 8000 can be used with a pre-tube. The advantage: You only need one measuring device for this application, which significantly reduces the costs of purchasing, maintaining and transporting devices in use. The use of pre-tubes is supported by a built-in assistant.

Inductive charging protects against wear and tear

The X-am 8000 features inductive charging. This makes it easier to operate and increases the lifespan of the device. Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazard zones) and measure at once, e.g, when using inside vehicles or on machinery.

The charging cradles can connect with one another, take up minimal space, and are compatible with existing Draeger X-am® series cradles.

Dimensions (H x W x D) 179 x 77 x 42 mm
Weight Approx. 495 g, depending on sensor configuration, without strap, without pump
Approx. 550 g, depending on sensor configuration, without strap, with pump
Housing Durable two-component housing
Display High-contrast color display
Temperature -20 °C to 50 °C
Pressure 700 to 1,300 hPa (measuring function)
800 to 1,100 hPa (use in explosion-hazard areas)
Relative humidity 10 to 90 % (short-term up to 95 %) r.h.
Alarms Visual: 3 LED 'red' (gas alarms), 3 LED 'yellow' (device alarms)
Acoustic: Multi-tone, typically 100 dB(A) at 30 cm
Vibration
Ingress protection class IP 68
Energy supply Lithium-ion battery, rechargeable, inductive charging
Operating times (diffusion) With CatEx and 3 EC sensors: Typically 24 hours
With IR and 3 EC sensors: Typically 22 hours
With 3 EC sensors: Typically 120 hours
With CatEx, PID and 3 EC sensors: Typically 17 hours
With IR, PID and 3 EC sensors: Typically 16 hours
With CatEx-, IR- and 3 EC sensors: Typically 14 hours
PID only: Typically 42 hours
Charging times Typically 4 hours after use during a shift of max. 10 hours
Start-up times Typically <60 seconds for standard sensors
Data storage 24 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing by the second on all 7 channels: approx. 400 hours
Pump operation Max. hose length 45 m
Approvals Explosion protection marking:
ATEX / IECEx: I M1, II 1G; Ex da ia I Ma, Ex da ia IIC T4 Ga
EAC: PO Ex da ia I Ma X; 0Ex da ia IIC T4 Ga X
cCSAus: Class I, Zone 0, AEx da ia IIC T4 Ga; Class II, Div 1, Gr. E, F, G; C22.2 No. 152, ANSI-ISA 12.13.01:2000
ANZEx: Ex da ia I Ma, Ex da ia IIC T4 Ga

Measurement performance:
Explosion protection according ATEX: EN 60079-29-1 (CatEx 125 PR, CatEx 125 PR Gas, (Dual) IR Ex, XXS H2 HC) CatEx 125 PR and (Dual) IR Ex: methane, propane, n-nonane, etc. The following applies to the CatEx 125 PR and approved gas n-nonane: Only in conjunction with nonane pump adapter, part number: 3720225
Oxygen deficiency/excess oxygen: EN 50104 (XXS O2 / XXS O2 PR)
Toxic gases: EN 45544-1, EN 45544-2, EN 45544-3 (XXS H2S LC, XXS CO LC, (Dual) IR CO2)
Software: EN 50271
Directives: 2014/34/EU (ATEX); 2014/30/EU (EMV); 2011/65/EU (RoHS); 2014/90/EU (MED)
Marine Approva: DNV GL
Manufacturer's warranty 3 years for the device
1 year for the power supply