1-866-4 JJSTECH(1-866-455-7832)

ScichemTech SCT-ORP-MAXI ORP Maxi Controller - SCT-108.005.12

Item #:
SCT-108-005-12
Brand:
ScichemTech
ScichemTech SCT-ORP-MAXI ORP Maxi Controller - SCT-108.005.12
$317.75
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
ScichemTech SCT-ORP-MAXI ORP Maxi Controller - SCT-108.005.12

ScichemTech SCT-ORP-MAXI ORP Maxi Controller - SCT-108.005.12

$317.75

SCT-108.005.12 SCT-ORP-MAXI ORP Maxi Controller by ScichemTech

Includes:

  • ORP sensor
  • Fixation clamps
  • Calibration solution
  • Instruction manual

Features:

  • SCT-ORP (Oxidation Reduction Potential) MAXI CONTROLLERS are designed with creativeness to get the elegance and produced with proper quality, and meets the specifications for the Water related applications with high level performance.
  • SCT -ORP (Oxidation Reduction Potential) MAXI CONTROLLERS are supplied with the suitable electrode with SCT standard 10 meters cable. (New series).
  • SCT-ORP (Oxidation Reduction Potential) MAXI CONTROLLERS are an industrial instrument used for online analysis and monitoring.
  • SCT-ORP (Oxidation Reduction Potential) MAXI CONTROLLERS are made in a attractive pleasant colour with a Large and Clear blue white LCD Display
  • SCT-ORP (Oxidation Reduction Potential) MAXI CONTROLLERS are Microprocessor based controllers, which gives stable and accurate readings.
  • SCT-ORP (Oxidation Reduction Potential) MAXI CONTROLLERS uses Low power consumption and produces less internal heat.
  • SCT-ORP (Oxidation Reduction Potential) MAXI CONTROLLERS has an isolated 4-20 mA current output.
  • SCT-ORP (Oxidation Reduction Potential) MAXI CONTROLLERS proved to work continuously in any harsh environmental conditions for the In line measurement and control of accurate ORP value and it give the the direct measurement and readings
Measurement range -1000~ +1000 mV
Accuracy ±2mV
Display mode 3 1/2 bit LCD with BACKLIGHT
Output current Isolate the active output of 4~20mA.
Output control Dual-contact output with both higher and lower limits (normally-open and normally-close respectively)
Contact capacity 7A/250V AC (resistive load)
Length of the cable 10 m
Screw size 3/4” pipe thread
Requirements on water samples Pressure: ≤0.3MPa Flow rate: ≤3 m/s
Power supply AC 220V±10%; 50Hz
Environmental conditions Temperature: 0~50°C Humidity: ≤85%RH
Overall dimension 96x96x120mm (Height x Width x Depth)
Face Opening 92x92mm
Installation method Panel-mounted

Questions & Answers


There are no questions or answers for this item.