1-866-4 JJSTECH(1-866-455-7832)

Quantrol Inline Flourometer, PTSA, 4-20mA / RS485 Modbus / Bluetooth - ST-500

Item #:
ST-500
Brand:
Quantrol
Quantrol Inline Flourometer, PTSA, 4-20mA / RS485 Modbus / Bluetooth - ST-500
$1,996.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Quantrol Inline Flourometer, PTSA, 4-20mA / RS485 Modbus / Bluetooth - ST-500

Quantrol Inline Flourometer, PTSA, 4-20mA / RS485 Modbus / Bluetooth - ST-500

$1,996.00

ST-500 Inline Flourometer, PTSA, 4-20mA / RS485 Modbus / Bluetooth by Quantrol

ST-500 series probes are UV excited inline fluorometers for measuring the concentration of PTSA in cooling tower and RO water systems. Capable of low-level detection in ppb + 1ppb.

Key Features

  • High resistance to color and turbidity interference from sample water
  • Digital communication via Bluetooth to smart phone app for diagnosis and troubleshooting
  • Highly stable and extremely reliable even in harsh applications

Accurate Traced Chemical Monitoring:

The ST 500 inline fluorometer, state of the art technology was developed by Pyxis Lab, Inc. in the United States. It measures traced chemical residue every 4 seconds in the sample water with 2% accuracy. It allows an optimal narrow band control in the treatment chemical concentration for cost effectiveness and, more importantly, best treatment performance.

High Rejection to Turbidity and Color Interference:

Turbidity and color in most cooling tower applications interfere traditional fluorimeters and lead to significant dosing errors, even up to 50%. With the ST 500's proprietary optical design and sophisticated compensation algorithm, the ST 500 delivers great precision and accuracy for waters containing up to 150 NTU turbidity and 4 ppm iron. This breakthrough technology ensures ST 500 to outperform in the toughest cooling water applications while keeping maintenance demand at a minimum with our uPyxis diagnostics capabilities.

Items ST-500 ST-500RO ST-500SS
PTSA range 0-200 ppb 0 to 40 ppb 0-200 ppb
Precision ±1% or ±1ppb ±1% or ±0.2 ppb ±1% or ±1ppb
Power Supply 22-36 VDC, ~1W
Output 4~20 mA isolated, RS-485 isolated
Connector IP67 water proof connector/cable 1.5 m (4.5 ft)
Operation Pressure Up to 0.7 MPa (100PSI) Up to 2.0 MPa (290 PSI)
At 65°C (150 °F)
Installation 3/4-inch NPT, panel mount by screws or pipe clamp
Storage temperature -20 °C ~ 60 °C (-4~140 °F)
Operational temperature 40 – 120 °F (4 – 49 °C) 32~150 °F (0 – 65.5 °C)
Housing material CPVC 304 Stainless Steel
Dimension Length 6.8 inch (172.7 mm), body diameter 1.44 inch (36.6 mm) 8.5 inch length, 2.25×2.25 inch header and 1.75 inch diameter body
Weight 0.37 lbs (170 grams) 2.5 lbs

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.