1-866-4 JJSTECH(1-866-455-7832)

Hanna Conductivity Analog Controller with Input from Probe or Transmitter, 1 µS/cm Resolution - HI8931CN

Item #:
HI8931CN
Brand:
Hanna Instruments
Hanna Conductivity Analog Controller with Input from Probe or Transmitter, 1 µS/cm Resolution - HI8931CN
$540.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Conductivity Analog Controller with Input from Probe or Transmitter, 1 µS/cm Resolution - HI8931CN

Hanna Conductivity Analog Controller with Input from Probe or Transmitter, 1 S/cm Resolution - HI8931CN

$540.00

Discontinued


HI8931CN Conductivity Analog Controller with Input from Probe or Transmitter, 1 µS/cm Resolution by Hanna Instruments

HI 8931 is a panel mounted conductivity controller designed for simplicity of use. For in-line applications, use the HI 7635 probe, while for tanks the HI 7638 with external threads is recommended. These probes are provided with a built-in NTC sensor for temperature compensated conductivity measurements.

HI 8931 also features a direct connection up to 20 m (67'), without needing to amplify the signal to the conductivity probe.

Using the HI 8931 in conjunction with a 4-20 mA output transmitter (HI 8936 or HI 8936L series) will assure a strong, interference free signal at distances up to 300 meters (1000').

  • Both electrode and transmitter compatible inputs accepted
  • Selectable manual ON, OFF and automatic dosing control with indicator
  • Built-in auto-diagnostic function for offset and slope
  • Both 4-20 and 0-20 mA output user selectable, all in one instrument
  • Backlit LCD
  • Transparent splash-proof cover included
  • Operational mode LED indicators

Order Information:

The HI 8931 series is supplied with mounting brackets and instructions.

Range 0 to 1999 µS/cm
Resolution 1 µS/cm
Accuracy @ 20 °C ±2% F.S. (excluding probe error)
Input from Transmitter HI 8936C / CL
Temperature Compensation automatic, 0 to 60°C with ß=2%/°C; see also transmitter HI 8936
Inputs DIN (probe) or 4-20 mA (transmitter)
Conductivity Probe HI 7635 for in-line applications or HI 3001D for flow-thru (not included)
Calibration manual, two point, through offset and slope trimmers
Recorder Output 0 to 20 mA or 4 to 20 mA (isolated)
Setpoint and Alarm Relay 1, Isolated, 2A, max. 240V, resistive load, 1,000,000 strokes
Setpoint Range 0 to 1999 µS/cm
Alarm Range 0 µS and 1000 µS
Dosing Control OFF/AUTO/ON with selection switch
Over Dosing Control adjustable, from 5 min to 60 min with knob or disable by wire strap - on rear panel
Backlight continuous on
Power Supply 115 VAC ±10% or 230 VAC ±10%; 50/60 Hz
Enclosure flame retardant ABS body and front panel; transparent splash-proof front cover
Environment -10 to 50°C (14 to 122°F); RH max 95% non-condensing
Panel Cutout 141 x 69 mm (5.6 x 2.7")
Weight 1 kg (2.2 lbs.)

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.