- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Draeger
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- IGD
- mPower
- MSA
- RAE Instruments
- RKI Instruments
- WatchGas
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Honeywell Analytics Control Card, Single Channel, 5701 - 05701-A-0351
Item #:
05701-A-0351
Brand:
Honeywell Analytics
Share this product:
05701-A-0351 Control Card, Single Channel, 5701 by Honeywell Analytics
This provides a single channel control function within a 1" wide package.
- Independent single channel operation
- Plug-in input and output options
| Back lit LCD | Bar graph + peak reading, digital, alphanumeric |
| Front Panel Facilities | Red LED: A1, A2, A3 Yellow LED: fault, inhibit Green LED: power Push button: alarm reset / card select |
| Remote Facilities | Inhibit and remote alarm reset |
| Supply Voltage | 18V to 32VDC |
| Power Consumption | Catalytic: 3.75W 4-20mA: 3.25W |
| Display / Alarm Point | Linearity: 1% FSD Repeatability: 1% FSD |
| Electronic Drift | Less than 2% / 6 months |
| Operating Temperature | -5°C to +55°C |
| Storage Temperature | -25°C to +55°C |
| Operating Humidity | 20-90% RH (non condensing) |
| Dimensions | 3U high x 25mm wide |
| Weight | 165g |
| Approvals | EN50270 |
| Catalytic Bridge Input | |
| Drive Method | Constant current |
| Current Range | 70mA to 283mA |
| Full Scale Range | 15mV to 600mV |
| Maximum Line Resistance | 40 ohms at 250mA (including sensor) |
| 4-20mA Input | |
| Loop Powered Voltage | 23V ± 5% isolated |
| Sensor Configuration | current sink or source |
| Signal Measurement Range | 0 to 25mA |
| Maximum Loop Resistance | 500 ohms (including sensor) |
| Analogue Output Option | |
| Measurement Signal Range | 0 to 20mA or 4-20mA |
| Linearity From Input | Better than 2% FSD |
| Repeatability From Input | Better than 1% FSD |
| Configuration | Isolated current sink or source (with external supply) |