1-866-4 JJSTECH(1-866-455-7832)

Honeywell Analytics Vertex M Rack (110 VAC) with One (1) Pyrolyzer Analyzer - 1290-0073

Item #:
1290-0073
Brand:
Honeywell Analytics
Honeywell Analytics Vertex M Rack (110 VAC) with One (1) Pyrolyzer Analyzer - 1290-0073
$65,398.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Honeywell Analytics Vertex M Rack (110 VAC) with One (1) Pyrolyzer Analyzer - 1290-0073

Honeywell Analytics Vertex M Rack (110 VAC) with One (1) Pyrolyzer Analyzer - 1290-0073

$65,398.00

1290-0073 Vertex M Rack (110 VAC) with One (1) Pyrolyzer Analyzer by Honeywell Analytics

Vertex M is the industry's most flexible, advanced toxic gas monitoring system offering parts per billion detection levels and physical evidence of a gas leak. Vertex M ensures productivity as well as life safety.

Flexible

The Vertex M System includes as standard one eight-point analyzer. As your monitoring needs change, Vertex M expands, offering you up to 24 points of continuous gas detection. Place your sampling points up to 400 feet (120 meters) from the system. There is a choice of universal analyzer modules and/or pyrolyzer analyzers. (Note: If Vertex M is used with one pyrolyzer module, the maximum number of points of detection is 16.)

Reliable

Vertex M offers powerful, built-in system redundancy as standard equipment to effectively safeguard against downtime.

  • Back-up pump and internal power module
  • Chemcassette® technology provides physical evidence of gas event
  • System data back-up (if main data acquisition PC fails, analyzers continue to monitor, log data and alarm)
  • Automated leak test with line integrity option

Easy to use

  • Touch screen for easy access to data
  • Software updates via CD-ROM or network to all system components
  • Configuration profile editing and data retrieval are all achievable without taking unit offline
  • Radio frequency identification tag (RFID) ensures Chemcassettes® are installed into appropriately programmed analyzer, eliminating human error
  • On-line help system

Security

  • Multiple levels of password protection
  • Reconfigure security setup without taking unit offline

Low cost of ownership

  • Vertex's M smaller footprint and greater density of points reduce your cost per point
  • Eight points per analyzer lowers Chemcassette® costs
  • Maximized 24 point systems provide low cost per point as compared to other continuous monitors
  • One system monitors up to three gas families and more than 40 gases
  • You can split your sample to more than one analyzer

Easy to maintain

  • Vertex M uses cost-effective XP Chemcassettes®, providing up to three months of continuous monitoring
  • Simplified replacement of Chemcassettes® and automated optics verification
  • No dynamic calibration required
  • One-touch flow balancing
  • Easy access to analyzers, pumps, power supplies and touch screen from front panel
  • Onscreen interactive electronic manual

Advanced communications

  • Built-in configurable PLCs with optional 64 relay contacts non-isolated; 32 isolated
  • Standard OPC interface for easy integration into your existing factory automation system or HMI
  • Optional Ethernet/CIP, LONWORKS®, DeviceNetTM, DF1 Interface, PROFIBUS, Modbus Plus, Modbus/TCP, ControlNet or 4-20mA outputs available
  • Optional Chemcam camera permits viewing of stain, locally or remotely, for proof of gas event. Image is electronically saved for future retrieval.
  • Optional remote control/viewing software enables total visualization of the monitor screens at a remote PC
General Specifications
Uses 8 to 24 point toxic gas monitor configurable for use with up to 3 universal Chemcassette analyzers or combination 1 pyrolyzer analyzer/1 universal Chemcassette analyzer
Power requirements 110 or 230 VAC
Physical dimensions
Height 56 in. (144.8 cm)
Width 24 in. (61 cm)
Depth 36 in. (91 cm)
Weight 551 lbs. (250 kg) with 3 analyzers
Universal Analyzer: 31 lbs. (14 kg)
Pyrolyzer Analyzer: 48 lbs. (22 kg)
Empty Vertex M Rack: 458 lbs. (208 kg)
Tubing dimensions
Sample lines ¼ in. (6.35 mm) O.D. x 0.190 in. (4.83 mm) I.D. FEP Teflon or ¼ in. (6.35 mm) O.D. x 0.156 in. (3.9 mm) I.D. FEP Teflon Sampling Distance: Up to 400 ft. maximum
Exhaust line ½ in. (12.7 mm) O.D. x 3/8 in. (9.5 mm) I.D. polypropylene tubing, Exhaust line: 50 ft. (15 m) maximum
Operating characteristics
Operating Voltage 110 or 230 VAC ± 10% (underload) @ 50/60 Hz; 15 Amps maximum, single phase
Operating Temperature 59°F to 95°F (15°C to 35°C)
Operating Humidity 20-65% RH
Operating Altitude –1000 ft. (–305 m) to 6000 ft. (1829 m) above sea level
Communications/Interface
Network Interface OLE for Process Control (OPC) Interface
Output Options DeviceNet, ControlNet, Profibus - DP, LonWorks, DF1, Modbus/TCP, ModBus Plus, Ethernet/CIP
Analog Option 4-20 mA (24 channels)
Relay Options Isolated (08X) or Non-Isolated (016X); Via PLC: 32 relays for 8 channel isolated relay option; 64 relays total for 16 channel non-isolated relay option
Alarm/Fault Capable of A1 and A2 alarms per point, per point maintenance/instrument faults, as well as general analyzer A1, general analyzer A2, and general analyzer instrument/maintenance faults
HMI/LCD Screen 1024 x 768 resolution, touch screen operation with at-a-glance system status.
Other Optional Accessories
  Sample line integrity test
Duct adaptors
ChemCam video monitoring camera
Remote viewing/control software

Questions & Answers


There are no questions or answers for this item.