1-866-4 JJSTECH(1-866-455-7832)

Casella Apex IS Pro Pump with No Charger Unit (UL & ATEX Approved Version)

Item #:
182160B
Brand:
Casella
Casella Apex IS Pro Pump with No Charger Unit (UL & ATEX Approved Version)
$875.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Casella Apex IS Pro Pump with No Charger Unit (UL & ATEX Approved Version)

Casella Apex IS Pro Pump with No Charger Unit (UL & ATEX Approved Version)

$875.00

Discontinued


182160B Apex IS Pro Pump with No Charger Unit (UL & ATEX Approved Version) by Casella

The new Apex IS range of personal sampling pumps has been developed to provide sampling capabilities between 0.005 and 4 l/min. Approval from the UL in the USA mean that the pumps can be used in any circumstance where intrinsic safety is an issue. Two main models are available in the range; the Apex Standard IS and the Apex Pro IS. Ease of use and utmost reliability were uppermost in the designer’s minds during the development of these quality pumps from Casella CEL. Digital circuitry ensures precise and constant control of the flow rate.

Key Benefits

  • Wide operating range from 800 ml/min to 4 l/m directly
  • 5 to 750 ml/m with low flow adaptor for vapors
  • Direct volumetric flow control
  • Long term stability between calibrations
  • Infra-red communications for simplicity of downloads with Pro model
  • Pro model stores up to 100 events in memory
  • Drop in fast charger to get back up and running quickly
  • Gas bag outlet for grab sampling of gasses
  • Standard IS model pump upgradeable to Pro IS pump version via PC software

Applications

  • Personal sampling for particulates in the breathing zone
  • Designed to comply with EN1232, MDHS 14/3, NIOSH 0600 requirements
  • Available in single kits
  • Available in multiple 5 pack kits with a 5 way charger or 5 separate chargers
  • Three buttons on the pump and a customized LCD make the user interface intuitive

A full range of sampling heads and filter cassettes are available from Casella CEL for measuring respirable, total inhalable and the PM fractions depending on the measurement protocol being followed. You can be confident that the pump will maintain a constant flow during the measurement and will alert the user should a problem occur with the flow due to a restriction or blocked filter.

Operation and use

The Casella Pump Manager software is available for use with the logging functions of the Apex IS Pro model and handles all the setup and downloading of the relevant pump run data for comprehensive reporting and archiving. Maintain a database of your measurements including the pump details and individual personal data. A drop in fast charger intelligently charges the Apex IS pumps and maintains them at peak power ready for a new measurement.
Flow range 0.8 to 4.0 liters/minute standard flow rate
(5 to 750 milliliters/minute with Low Flow adaptor)
Flow control accuracy <±3.0% for selected flow digitally controlled for utmost stability
Flow performance
(Flow, max back pressure)
1.0 liter/minute @ 32 in H2O (80 cm H2O)
2.0 liters/minute @ 22 in H2O (55 cm H2O)
3.5 liters/minute @ 6.4 in H2O (16 cm H2O)
Battery voltage and capacity 4.8 V NiMH / 1.7 Ah
Inlet pulsation ratio <10% using cyclone
@ 2.0 liters/minute approx. 3.0 in H2O
Satisfies NIOSH 0600 and EN 1232
Displayed values Real time flow rate, volume sampled, elapsed sample time, temperature, operating mode, program details
Pump MTBF (service interval) Typically >3000 hours
Operating temperature 41 to 104 °F (5 to 40 °C)
Storage temperature 14 to 122 ° F (-10 to 50 °C)
Charging technique Drop in intelligent fast charger <1.5 hrs gives 8 hr run time
Typical charge time Fast charge with safety time out, takes 4.5 hours to fully charge pump
External Power Supply Unit
(for drop in charging)
Casella 182261B single pump fast charger or 182226A 5 way pump fast charger keeps pump(s) always ready for use
Memory storage of data 100 events saved in Apex Pro IS model
Memory protection time Approximately 20 minutes (with main battery removed)
Communications Infra red (via RS232 IR transducer) to Pump Manager software
Recorded values Start and stop times, duration flow rate, average sample temperature, total volume sampled (in l or m3) error conditions such as blockages
Physical characteristics:  
Size
5.8 x 3.4 x 1.8 in (145 x 85 x 46 mm)
Weight (inc. battery)
17.8 oz (500 gm)
Intrinsic Safety Approvals UL/CSA Class I, Divisions 1 & 2, Groups C & D; Class II, Divisions 1 & 2, Groups E, F & G; Class III hazardous
locations
ATEX: 100-94/9/EC Directive EEx ia IIB T4, Equipment group II Category 1 G Gas, EN 50014, EN 50020, EN 1232 : 1997
Pump Performance
 
Typical filter pressure load in inches of H2O, typical battery life in hours
Filter type 1.0 liter/min 2.0 liters/min 3.0 liters/min 3.5 liters/min 4.0 liters/m
25 mm GFA 2.0 in, 51 hrs 3.0 in, 26 hrs 4.0 in, 15 hrs 5.0 in, 11 hrs 5.3 in, 2 hrs
25 mm 0.8 μm 6.5 in, 31 hrs 11.0 in, 13 hrs 15.0 in, 1 hrs 17.0 in, N/A 19.0 in, N/A
25 mm 1.2 μm 4.5 in, 42 hrs 11.0 in, 18 hrs 10.0 in, 11 hrs 11.8 in, <1 hr 12.5 in, N/A
37 mm GFA 0.5 in, 58 hrs 1.5 in, 31 hrs 2.0 in, 17 hrs 2.5 in, 13 hrs 2.6 in, 12 hrs
5” backpressure 33 hrs 20 hrs 13 hrs 11 hrs 3 hrs

Questions & Answers


There are no questions or answers for this item.