1-866-4 JJSTECH(1-866-455-7832)

GfG GMA 200-MT16/14 GMA 200 Controller, Configured for 14 Measuring Points - 2200-014

Item #:
2200-014
Brand:
GfG
$3,545.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
GfG GMA 200-MT16/14 GMA 200 Controller, Configured for 14 Measuring Points - 2200-014

GfG GMA 200-MT16/14 GMA 200 Controller, Configured for 14 Measuring Points - 2200-014

$3,545.00

2200-014 GMA 200-MT16/14 GMA 200 Controller, Configured for 14 Measuring Points by GfG

For more than 50 years, the key goal of GfG has been to meet the highest demands of occupational health and safety, industrial equipment reliability and environmental protection. This goal has been reached by developing innovative and reliable gas warning systems. Development of the new GMA 200 gas warning system satisfies these requirements while taking into account suitability testing in line with ATEX Directive 94/9/EC. If switching functions for explosion protection are required, the GMA 200 gas warning system is the optimal solution. It also meets the requirements for gas warning systems without necessary ATEX certification and functional safety requirements (SIL).

Design of the GMA 200 gas warning system

The design of the GMA 200 gas warning system ensures flexible and simple operation in industrial and commercial applications for measuring combustible and toxic gases / vapors, and for measuring oxygen concentrations. The compact design of the GMA 200 as a DIN rail module enables cost-effective and space-saving installation.

Modular design of the GMA 200 MT6 / MT16 gas warning system

Up to 16 detectors can be connected to the GMA 200 gas warning system. A software program enables the quick and easy configuration of the measuring points for already installed GMA 200 gas warning systems. Measuring point designations, the detector type, the type of gas and measuring range as well as three individual or specified alarm thresholds can be programmed for each measuring point using the configuration software. A microprocessor evaluates the analog input signals of the connected detectors.

Integrated relays

As a result of the increasing requirements being placed on safety measures, even redundant protection against gas hazards, complex gas warning systems are in demand. The GMA 200 gas warning system is equipped with 8 internal relays. 6 relays can be freely configured using the software program in order to implement safety measures and alarms. The configuration software offers numerous and flexible options, such as the assignment of one or several measuring points to relays, single alarms per measuring point and alarm threshold, configuration of collective or group alarms and fault messages and voting functions. Two further relays are available for safety-related fault messages and for maintenance.

Relay modules

Using a GMA RT relay module, it is possible to extend the GMA 200 gas warning system by 16 additional freely configurable relays. A total of 4 additional relay modules and thus 64 additional relays can be managed via the GMA 200 gas warning system. Digital connection of the GMA RT relay module to the GMA 200 gas warning system enables the local positioning of the relay modules. The local and thus flexible installation of the relay modules results in large cost savings due to reduced cabling and assembly functions.

Availability of the gas warning system

Besides the traditional voltage supply, the GMA 200 gas warning system can also be operated with a redundant, safety-related voltage supply and therefore meets the highest demands of functional safety and the required permanent availability of gas warning systems for detecting potential gas hazards.

System functions: LED displays

The status of the GMA 200 gas warning system – operation, fault, service – is shown via LEDs.

Graphical display

The clearly structured layout of the GMA 200 gas warning system enables the quick detection of hazardous situations. Currently measured values are permanently displayed on the LCD graphical display. In the event of gas alarms, the display lighting is automatically activated with a red background.

Additionally, the LED display for Alarm 1, Alarm 2, Alarm 3 is shown. In the event of an alarm, the status of the active relays 1-8 is displayed simultaneously via LEDs.

The integrated memory enables the reading of alarm levels and minimum / maximum values per measuring point at the LCD for an initial, quick hazard assessment.

Data logger function

The GMA 200 gas warning system can be equipped with a micro SD card for saving the measured values. The measured values, mean values, alarm events and faults are permanently stored at individually configurable intervals, and can be read out for evaluation.

Operation via keyboard

Five buttons enable operation at the GMA 200 gas warning system. The main functions of the keyboard are the acknowledgement of alarms and the menu-driven operation. Information on the status of the gas warning system, detector and the relays can be retrieved in the operating menu.

Configuration

A USB port at the GMA 200 gas warning system can be used for connection to the configuration software.

Features

  • A variety of transmitters can be connected for measurement of combustible, toxic gases/vapors and oxygen
  • Multiple relay configurations
  • Flexible, reliable and economic
  • Intuitive, backlit graphical LCD with "traffic light function" (green, amber, red)
  • SIL certification
  • DIN rail mounting
Gas Combustible, oxygen, and toxic gases/vapors, for all GfG transmitters.
Ambient Temperature Operation: -4 to +122°F / -20°C to + 50ºC
Storage: -22 to +140°F / -30°C to + 60°C
Humidity 30 to 96 % r.h.
Power Supply 2 x 24 V DC, 20-30 V
(1 x redundant voltage supply)
Power Consumption GMA 200–MT6 gas warning system:
30 W including connected detectors
GMA 200–MT16 gas warning system: 5 W
GMA 200 RT relay module: 6 W
Input Signal 16 analog inputs 4…20 mA or 0.2-1 mA max. 50 Ohm input resistance
2 digital inputs: Acknowledgement of alarms can be freely configured
2x RS485 BUS, e.g., for the connection of external relay modules or digital transmitters in BUS wiring
1x RS485 BUS for the digital transfer of measured and output data to a higher-level control center or with master functionality of a GMA 200 for the connection of GMA 200-RT relay modules
Output Signal 6 relays (normally open contact), freely configurable for single alarms per measuring point and alarm threshold, configuration of collective or group alarms, fault messages and voting functions
1 relay for maintenance and 1 for fault messages (closed-circuit principle)
2 analog outputs: 4-20mA / 600 Ohm max. resistance, freely configurable
External Relay Module Up to 64 additional freely configurable relays (with additional relay modules, each with 16 relays)
Can be configured for single alarms per measuring point and alarm threshold, configuration of collective or group alarms, fault messages and voting function
Display and Control Elements Backlit LCD graphical display 33 x 53 mm with 132 x 65 pixels 5 buttons (left, right, up, down, OK)8 LEDs: 4x red, 1x green, 3x yellow
Connection Options GMA 200 – MT 6 gas warning system: Up to 6 analog detectors or digital detectors
GMA 200 – MT 7 -16 gas warning system: Up to 16 analog detectors or digital detectors
Function Keys 3 independent threshold alarms per measuring point for Alarm 1, Alarm 2 and Alarm 3
Can be freely set in the measuring range
Alarm Functions Exceeding, not achieved resettable (additional horn only), non-resettable non-latching / latching
Data Storage Measured values can be stored on an SD card for the permanent data recording of measured values, alarms and faults
Intervals can be set (5 sec.-60 min.), recording of instantaneous and mean values, minimum/maximum concentration can be selected per measuring channel
Casings Wall mount casings for 2, 4, 7, 12, 24 or 36 controllers
Panel mount casings for 2, 4 or 7 controllers
19-inch racks for 12 controllers
Cabinets for large systems
Weight 21.7 ounces (620 grams)
Dimensions 3.5433x6.2992x2.5591 inches (90x160x65 mm) (HxWxD)
Protection Classes / Approvals Housing: IP20
ATEX approval: Applied for in accordance with ATEX 94/9/EC
Electrical safety: EN 61010:2010, Degree of soiling 2, Overvoltage category III for relay contacts
Electromagnetic compatibility: EN 50270:2006, Emitted interference type class I, Interference resistance type class II
Metrological suitability testing: Applied for according to DIN-EN 60079-29-1

Datasheets & User Manuals

Questions & Answers