1-866-4 JJSTECH(1-866-455-7832)

GfG 25 Series Control Panel with One Input Channel, 4-20 mA Output, Horn and Strobe, NEMA 4X Housing, Reset Switch Mounted on Outside of Enclosure - 2210-001XR

Item #:
2210-001XR
Brand:
GfG
GfG 25 Series Control Panel with One Input Channel, 4-20 mA Output, Horn and Strobe, NEMA 4X Housing, Reset Switch Mounted on Outside of Enclosure - 2210-001XR
$2,130.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
GfG 25 Series Control Panel with One Input Channel, 4-20 mA Output, Horn and Strobe, NEMA 4X Housing, Reset Switch Mounted on Outside of Enclosure - 2210-001XR

GfG 25 Series Control Panel with One Input Channel, 4-20 mA Output, Horn and Strobe, NEMA 4X Housing, Reset Switch Mounted...

$2,130.00

2210-001XR 25 Series Control Panel with One Input Channel, 4-20 mA Output, Horn and Strobe, NEMA 4X Housing, Reset Switch Mounted on Outside of Enclosure by GfG

The 25 series control panel is available in a single channel (2210-001X) or a one to four channel (2210-004X) version. The panel comes complete with controller, local display horn and strobe. The single channel version also features a 4-20 mA output

Alarm points

Each alarm can be adjusted separately. The alarm values can be freely adjusted within the detection range. Every alarm point value can be factory programmed to be latching/non-latching and resettable/non-resettable.

Alarm Relays

The controller provides four voltage-free relays for the three alarms and one fault warning. The relays may be used to control additional alarm devices like lights or horns.

Transmitters/Sensors

The 25 series control panel may be connected to any available GfG transmitter for detection of oxygen (O2), combustible gases (LEL) or any transmitter from a wide range of toxic gases.

Features

  • Complete control package available in single channel or 1-4 channel configurations
  • Compact design
  • Intuitive push button operation
  • 4-20 mA input standard (factory configurable to 0.2-1 mA)
  • 3 user-adjustable alarm hysteresis
  • Polycarbonate Industrial Enclosure
  • Easy installation
  • 4 relays (3 alarm and 1 fault)
  • Factory configured alarm functions include: Latching/non-latching; Resettable/non-resettable; Time delay; Rapid rise alarm for combustible setups
  • Local display, horn and strobe
  • 4-20 mA output (2210-001X)
  • 2 Amp power supply
Control Panels Any available GfG gas transmitter.
2210-001X: 1 transmitter
2210-004X: 1 to 4 transmitters
Add "R" to part number for reset switch
2000230 - push button reset (optional)
Humidity 0 to 99% r.h. non-condensing
Temperature Range 32° to +131°F (0 to +55°C)
Pressure 700 to 1,300 hPA
Power Supply 24 VDC, 2 Amp
Weight 7.25 # (3.3 kg)
Dimensions 17x11.5x6 inches (43.2x27.4x 15.2 cm) (HxWxD)
Display 3-digit LED display
1 LED green - operational status
1 LED yellow - fault
3 LED red - alarm
Display of maximum / minimum values
Alarms 3 alarm points
User adjustable within the detection range
Alarm Functions Available Exceeding / descending
Latching / non-latching
Resettable / non-resettable
Hysteresis adjustable
Delay-time 0 to 2 minutes
Relays 3 alarm points, 1 fault - voltage free
Factory setting
A1 - strobe
A2 - open
A3 - horn
Fault - open
Voltage: 250 VAC 50/60 Hz or 250 VDC maximum
Amperage: 4 A AC/DC
Output Signal Linear 4-20 mA (2210-001X only)
Horn Low - 70 db at 1 m
High - 90 db at 1 m
Strobe Red, flashing 60 Flashes per minute

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.