1-866-4 JJSTECH(1-866-455-7832)

Bacharach 3015-4200 HGM-SZ Single Zone Monitor, 120-240 VAC / 50/60Hz Input Power

Item #:
3015-4200
Brand:
Bacharach
Bacharach 3015-4200 HGM-SZ Single Zone Monitor, 120-240 VAC / 50/60Hz Input Power
$5,171.40
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Bacharach 3015-4200 HGM-SZ Single Zone Monitor, 120-240 VAC / 50/60Hz Input Power

Bacharach 3015-4200 HGM-SZ Single Zone Monitor, 120-240 VAC / 50/60Hz Input Power

$5,171.40

3015-4200 HGM-SZ Single Zone Monitor, 120-240 VAC / 50/60Hz Input Power by Bacharach

The Bacharach Single-Zone family of fixed point gas monitors is available for the detection of refrigerants, halogen gases (HGM-SZ) and ammonia (AGM-SZ). The Single-Zone series is designed around Bacharach’s proprietary infrared sensing technology to offer reliable, superior sensing performance.

Bacharach's infrared (NDIR) sensors offer users one of the most feature loaded, lowest-cost-of-ownership monitors available. The Single-Zone monitors feature automatic calibration, eliminating the need for costly calibrations. Periodic filter replacements are practically the only maintenance required.

An easy-to-install, out-of-the-box solution, Bacharach's Single-Zone monitors offer an onboard power supply, LCD display for real-time readings and LED indicators with dedicated relays that activate audible or visual alarms. A 4-20 mA output enables a compatible connection to standard building automation systems.

Features & Benefits:

  • Proprietary infrared sensing technology virtually eliminates false alarms and extends sensor life
  • Capable of detecting and measuring any CFC, HFC, and HCFC refrigerant gas or ammonia
  • Provides continuous, unattended monitoring from up to 500 ft. (152.4 m) away from measuring point
  • Measurement range of 0-10,000 ppm with sensitivity of 1 ppm
  • Logging feature enables 200 gas readings to be stored at user-selectable time intervals
  • No costly calibration required
Part Number 3015-4200
Includes HGM-SZ single zone monitor with: 1 termination filter, 15.24 m (50 ft.) of sample line tubing.
Measures R-11, R-12, R-22, R-23, R-113, R-114, R-123, R-124, R-125, R-134a, R-227, R236FA, R-401a, R-402a, R402b, R-404a, R-407a, R-407c, R-408a,
R-409a, R-410a, R-500, R-502, R-503, R-507, R-508b, H-1211, H-1301, H-2404, N-1230
Measuring Range 0 to 1,000 ppm
Sensitivity 1 ppm
Accuracy ± 1 ppm ± 10% of reading from 0 to 1,000 ppm
Detector Type Single-pass Non-Dispersive Infrared (NDIR)
Inputs Dedicated single zone
Output Signal 3 SPDT, 3 Amp, 250 VAC rated alarm relays and 1 SPDT, 3 Amp, 250 VAC rated system fault relay, plus a digital display with dedicated 4-20 mA DC analog output (floating ground)
Monitoring Distance Maximum 152.4 m (500 ft.) from measuring point to monitor
Response Time 9 to 90 seconds, depending on sample tube length
Front Panel Display Green LED: indicates unit is operating properly
Yellow LED: indicates clogged sample line or other system fault
Red LED: indicates when any monitored point exceeds alarm settings
Power 100 to 240 VAC, 50/60 Hz
Size / Weight 13.7" x 7.7" x 3.6" / 7 lbs. (347.98 mm x 195.58 mm x 91.44 mm / 3.175 kg)
Approvals UL 61010-1 • CSA 22.2 No. 61010-1 • EN 14624 • CE Mark

Questions & Answers


There are no questions or answers for this item.