1-866-4 JJSTECH(1-866-455-7832)

RKI Instruments 35-3001 Multi-Gas Version Sample Draw Detector Assembly (No 4-20 mA transmitter) for Combustibles 100% LEL / IR Carbon Dioxide 0-5% - 35-3001-11

Item #:
35-3001-11
Brand:
RKI Instruments
RKI Instruments 35-3001 Multi-Gas Version Sample Draw Detector Assembly (No 4-20 mA transmitter) for Combustibles 100% LEL / IR Carbon Dioxide 0-5% - 35-3001-11
$1,995.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments 35-3001 Multi-Gas Version Sample Draw Detector Assembly (No 4-20 mA transmitter) for Combustibles 100% LEL / IR Carbon Dioxide 0-5% - 35-3001-11

RKI Instruments 35-3001 Multi-Gas Version Sample Draw Detector Assembly (No 4-20 mA transmitter) for Combustibles 100% LEL / IR Carbon Dioxide...

$1,995.00

35-3001-11 35-3001 Multi-Gas Version Sample Draw Detector Assembly (No 4-20 mA transmitter) for Combustibles 100% LEL / IR Carbon Dioxide 0-5% by RKI Instruments

The 35-3001 series is a compact sample draw detector assembly with a built-in pump that is powered from 24VDC. This unit features a NEMA 4X enclosure, making it dust, water and corrosion resistant. It also features a low flow alarm which warns of any obstructions or restrictions in the flow system. Combustibles, oxygen, and carbon dioxide versions are available with or without a 4-20 mA transmitter. H2S and CO versions both have 4-20mA outputs. The 35-3001 is also available in many dual sensor configurations.

The 35-3001 is capable of single person calibrations and remote sampling at up to 5,000 ft. from a controller, and interfacing to any RKI or third party control system (utilizing a 4-20 mA feedback signal).

Features:

  • Available in LEL, O2, H2S, CO, CO2, H2 (ppm or LEL)
  • Multigas versions available with sensors in one enclosure
  • Internal sample pump with 100' range
  • Flowmeter and LED's for operational status
  • Low flow indication
  • NEMA 4X enclosure
  • Operates on 24VDC input
  • Optional 4-20mA output

Applications:

  • Petrochemical plants
  • Refineries
  • Water & wastewater treatment plants
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • HVAC

*Please note we can only ship RKI products to customers within the United States

Specifications
LEL
LEL
O2
H2S
CO
H2
CO2
Sensor Type
Catalytic
Infrared
Galvanic cell
Electrochemical
MOS
Infrared
Measuring Range
0-100% LEL
0-100% LEL for CH4 and HC's
0-25% Vol.
0-100 ppm
0-500 ppm
0-2000 ppm
0 - 5000ppm
0 - 5.0% Vol.
0 - 50% Vol.
0 - 100%Vol.
Signal Output
RKI direct connect sensors (requires RKI controller) optional 4-20mA output (standard for CO/H2S)
Operating Voltage
24VDC nominal (18.5 - 30VDC)
Max Current Draw
250 mA 24VDC
Location
Indoor or outdoor
Temperature
-4 to 122° F (-20 to 50°C)
Humidity
0 - 95% RH non condensing
Housing
Grey polycarbonate wall-mount hinged NEMA 4X
Dimensions
Height: 8.5" (216 mm)
Width: 7.0" (178 mm)
Depth: 4.3" (109 mm)
Sampling Method
Internal sample draw pump
Maximum Sample Length
100 Ft.
Sample Connections
1/4" OD rigid tubing (inlet and exhaust)
Display
Flow meter, LED's for pilot and fail
Warranty
One year, materials and workmanship

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.