    570-04WB 4-Channel 570 Wall Mounting Housing with Buzzer Module by RKI Instruments

    Features:

    • Available to connect to various gas sensor
    • Easy to read three color (green/orange/red) LED bar-graph display (52 segments)
    • Combustible gases detectable in wide range (from PPM to %LEL) with one display unit (NC-581W)
    • Automatically changes from ppm range to %LEL range (NC-581W)
    • Two alarm levels
    • Peak hold function
    • Highly integrated compact design with plug-in type unit
    • Zero suppression function
    • Alarm contact interruption function (Maintenance mode)
    • Alarm test mode
    • Auto zero function
    • Ability to indicate a flow failure alarm
    • Output signal (4~20mADC) is provided

    Applications:

    • Petro-refinery, petrochemical plants
    • Chemical plants
    • Semi-conductor manufacturing plants
    • Engineering public work field
    • Power station, gas work
    • Iron and steel works

    *Please note we can only ship RKI products to customers within the United States


    RM-580 Specifications:
    Power Requirements 115 VAC and 24 VDC with 230 VAC optional
    Sampling Method Accepts both diffusion and sample drawing type detector heads
    Operating Conditions 0 - 122 F, 10 - 90% RH, non-condensing
    Enclosure Type Metal module
    Mounting Style Wall mount for 4, 6, or 12 modules
    Display Method 3 color LED bar graph (52 segments)
    Alarms 2 per module, 2 common relays, external reset
    Alarm Indication 1st alarm flashing LED (orange), latched, continuous light when reset
    2nd alarm flashing LED (red), latched mode
    Output Signal 4-20 mA DC
    Audible Alarm Enclosure mounted buzzer, 94 dB at 1'
    Coded output: pulsing = gas alarm, steady = fail
    Sensor Inputs Any 4-20 mA transmitter, 24 VDC, 2 or 3 wire, 250 mA max standard. LEL or Oxygen sensors direct connect.
    Warranty One year materials and workmanship


    Partial List Of Detectable Gases
    Ammonia (NH3) 0 - 75.0 ppm
    Arsine (AsH3 ) 0 - 0.20 ppm
    Boron Trichloride (BCl3) 0 - 15.0 ppm
    Carbon Dioxide (CO2) 0 - 1.0 %
    Carbon Monoxide (CO) 0 - 300 ppm
    Chlorine (Cl2) 0 - 3.0 ppm
    Chlorine Dioxide (ClO2) 0 - 1.00 ppm
    Chlorine Trifluoride (ClF3) 0 - 1.00 ppm
    Combustibles 0 -100% LEL
    Diborane (B2H6) 0 - 30.0 ppm
    Fluorine (F2) 0 - 6.0 ppm
    Hydrogen (H2) 0 - 2000 ppm
    Hydrogen Chloride (HCl) 0 - 15.0 ppm
    Hydrogen Fluoride (HF) 0 - 9.0 ppm
    Hydrogen Sulfide (H2S) 0 -100.0 ppm
    Nitric Oxide (NO) 0 -100.0 ppm
    Nitrogen Dioxide (NO2) 0 - 15.0 ppm
    Nitrogen Trifluoride (NF3) 0 - 30.0 ppm
    Oxygen (O2) 0 - 25.0 %
    Ozone (O3) 0 - 1.0 ppm
    Phosphine (PH3) 0 - 1.0 ppm
    Silane (SiH4) 0 - 15.0 ppm
    Sulfur Dioxide (SO2) 0 - 30.0 ppm
    TEOS (Si(OC2H5)4) 0 -15/30 ppm