1-866-4 JJSTECH(1-866-455-7832)

Bacharach 6201-5114 IAM-100 Gas Detector, Remote Sensor/Faceplate, CH4 0-5000ppm, 110 VAC

Item #:
6201-5114
Brand:
Bacharach
Bacharach 6201-5114 IAM-100 Gas Detector, Remote Sensor/Faceplate, CH4 0-5000ppm, 110 VAC
$422.50
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Bacharach 6201-5114 IAM-100 Gas Detector, Remote Sensor/Faceplate, CH4 0-5000ppm, 110 VAC

Bacharach 6201-5114 IAM-100 Gas Detector, Remote Sensor/Faceplate, CH4 0-5000ppm, 110 VAC

$422.50

6201-5114 IAM-100 Gas Detector, Remote Sensor/Faceplate, CH4 0-5000ppm, 110 VAC by Bacharach

The IAM-100 Gas Monitor from Bacharach offers exceptional continuos monitoring performance and flexibility at an economical price. By itself, or integrated into a comprehensive detection system, the IAM-100 is a scalable solution for detecting a variety of refrigerants, combustible gases and VOC gas leaks at the lowest possible cost.

Onboard LEDs illuminate when the sensor is in an alarm state while the unit's audible alarm alerts personnel in the area that levels have exceeded the desired limit. The audible alarm can be muted with the onboard silence switch. Integrated dual relays enable the IAM-100 to shut-off refrigerant or propane supply lines while the second relay can be used as a connection to a building BMS or BAS system.

The IAM-100 is an alarm threshold device. When the range of the sensor is exceeded, the detector will go into alarm. For example, a unit with a 1,000 ppm R-410a sensor will activate its alarm when the detected refrigerant meets or exceeds 1,000 ppm.

Features & Benefits:

  • Real-time continuous gas detection that's scalable, reliable and affordable
  • Ideal for commercial applications such as hotel rooms, apartments, dorms, hospitals, restaurant kitchens or battery charging rooms
  • Detects refrigerants (at ?1,000 or ?10,000 ppm), TVOCs (at ?1,000 ppm), combustible gases and hydrocarbons (at ?5,000 ppm)
  • Fast-responding, long-life sensors
  • Integrated visual LED and audible alarms
  • Two onboard relays to activate shut-off valves, exhaust fans, or connect to a BMS or fire panel
  • Remote sensor with aesthetic faceplate available for discreet monitoring in decorative interiors
General Specifications
  IAM-100 IAM Controller
Operating Power Supply 110 VAC/60 HZ or 220 VAC/50 Hz; 11 W Max 110 VAC/60 HZ or 220 VAC/50 Hz; 11 W Max
Power Status Green LED Green LED
Alarm Status Red LED Red LED
Fault Status Siren inactive, Green LED off, and Red LED on Siren inactive, Green LED off, and Red LED on
Audible Alarms Internal siren with mute button External siren with mute button
Siren Deactivate By onboard jumper By key switch
Alarm Relays (Volt Free) 2 Relays: 1 A @ 24 VDC 2 Relays: 10 A @ 230/120 VAC
Alarm Reset Selectable manual or automatic Remote reset, down stream resets any IAM-100 monitor or controller connected to a channel, after gas has cleared
Selectable Alarm Delay 0, 5, 10 or 15 minutes N/A
Warm-up Delay 5 minutes initially N/A
Enclosure Rating Standard: IP30 IP51
Cable Recommendations IAM to IAM-C:
16-24 AWG, 2-conductor
(7/0.2 mm, 2 conductor)
984.25 ft (300 m) max
IAM-C to IAM-C:
16-24 AWG, 2-conductor
(7/0.2 mm, 2 conductor)
984 ft (300 m) max
Approvals CE
UL/CSA 61010-1
CE
FCC Part 15, Subpart B
UL/CSA 61010-1
Standard Housing Size: 147x88x62 mm (5.8x3.5x2.4 in)
Weight: 633 g (1.4 lbs)
Faceplate (Brushed Steel) Housing Size: 86x86 mm (3.4x3.4 in)
Weight: 86 g (0.2 lbs)
Measurement Range 10 to 10,000 ppm (typical)
Temperature Range -4 to 122ºF (-20 to +50ºC)
Humidity Range 0 to 95% Non condensing
Sensor Life Time 5 to 8 years (typical) for semiconductor sensors
Typical Time to Alarm 24 seconds (Response times may vary based on temperature of operation, enclosure and environmental conditions)
Calibration Frequency See local regulations (annual test or calibration typical). Semiconductor sensors are non-selective, but calibrated to a specific gas.

Gas Specifications
Gas Type
Formula/Name
Detection Range
Standard Alarm Setpoints
HFCs
R134a, R404A, R407, R410A, R507
≥1,000 ppm or
≥10,000 ppm
Refrigeration: 1,000 ppm
Air Conditioning: 10,000 ppm
HCFCs
R22
≥1,000 ppm or
≥10,000 ppm
Refrigeration: 1,000 ppm
Air Conditioning: 10,000 ppm
CFCs
R11, R12
≥1,000 ppm or
≥10,000 ppm
Refrigeration: 1,000 ppm
Air Conditioning: ......................
Hydro-carbons
Methane (Natural Gas), Propane, Butane, LPG, Isobutane, H2
≥5,000 ppm
5,000 ppm
VOCs
Acetone, Chloroform, Ethanol, Methanol, Methyl and Methylene Chloride, Ethyl and Ethylene Chloride
≥1,000 ppm
1,000 ppm