1-866-4 JJSTECH(1-866-455-7832)

Bacharach 6203-0011 MVR-300 Variable Refrigerant Flow Gas Detector, 100-240VAC, Low and High Alarm, Modbus, LED and 80dB Alarm - R-407c, 0 to 2500 ppm

Item #:
6203-0011
Brand:
Bacharach
$538.20
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Bacharach 6203-0011 MVR-300 Variable Refrigerant Flow Gas Detector, 100-240VAC, Low and High Alarm, Modbus, LED and 80dB Alarm - R-407c, 0 to 2500 ppm

Bacharach 6203-0011 MVR-300 Variable Refrigerant Flow Gas Detector, 100-240VAC, Low and High Alarm, Modbus, LED and 80dB Alarm - R-407c, 0...

$538.20

6203-0011 MVR-300 Variable Refrigerant Flow Gas Detector, 100-240VAC, Low and High Alarm, Modbus, LED and 80dB Alarm - R-407c, 0 to 2500 ppm by Bacharach

The MVR-300 detector is specifically designed to provide continuous monitoring for refrigerants associated with high-efficiency, high volume refrigerant cooling and heating systems, such as VRF/VRV (Variable Refrigerant Flow/Variable Refrigerant Volume) sytems. Typical applications include hotels, dormitories, hospitals, office buildings, and apartment buildings.

The MVR-300 audible and visual alarms alert occupants and simultaneously communicate to Building Management Systems/Building Automation Systems (BMS/BAS). Two on-board relays can be used to close valves, activate alarm devices and exhaust fans or initiate emergency calls to rescue teams.

The on-board Modbus RTU interface provides real-time information about refrigerant concentrations, status and settings. It also enables custom configuration of the MVR-300 to any application specific requirements using multiple Modbus registers. The MVR-300 is designed for easy installation and simple maintenance.

The MVR-300 is compatible with MVR-SC Controller.

Features

  • Fits in standard electrical boxes
  • Low profile/Flush mount
  • Two relays and Modbus Communications
  • Alarm options including: LED, buzzer, two levels, configurable delay and failsafe
  • Refrigerant specific sensor
  • Self diagnostics and simple field calibration
  • Unique plug-in field replaceable pre-calibrated sensor

Benefits

  • Easy to install
  • Aesthetically non-intrusive appearance
  • Notify building management & initiate counter measures
  • Alert occupants and remotely inform building management of alarm location for rapid response as required
  • Enhances safety and minimizes refrigerant loss
  • Easy to maintain
  • Low cost of ownership
SPECIFICATIONS
DESCRIPTION
Detectable Gases R-410a, R-407c, R-404a, R-32
Measuring Ranges 2,500 ppm, 5,000 ppm, 10,000 ppm
Housing Flush mount, white ABS, Fits in most 2 gang electrical back boxes
Size (L x W x D, approx.) 6" x 4.1" x 1.75" (150 x 105 x 45 mm) including bezel
Protection Indoor: IP40, NEMA 1
Weight (approx.) 8 oz (230 g)
Power 100 to 240 VAC, 50/60 Hz, 4 W max
Indicator Tri-color LED: green, amber, red
Buzzer 80 dB at 12" (30 cm)
Relay Two SPDT: low alarm and high alarm / fault, normal or fail-safe, configurable
Alarm Delay 0 to 15 minutes, configurable 0, 5, 10, 15
Wiring Power: 3-core cable, 14 to 20 AWG (0.5 to 2.0 mm2)
Relay: 3-core cable, 18 to 20 AWG (0.5 to 1.0 mm2)
Modbus: 2-core twisted pair shielded cable 18 to 24 AWG
Modbus RTU Baud Rate: 9,600 or 19,200, configruable
Environmental Conditions Operating Temperature: 32 to 120 °F (0 to 50 °C)
Storage Temperature: 5 to 100 °F (-20 to 40 °C)
Humidity: 5 to 90% RH, non-condensing
Pressure: 23.6 to 32.5 inch of Hg (800 to 1,100 hPa)
Elevation 0 to 6,560 ft. (2,000 m) altitude
Sensor Life 2 year minimum life with recommended 6 month testing and/or recalibration
Approvals CE, UL/SCA/IEC/EN 61010-1
REFRIGERANT
P/N
LOW ALARM
HIGH ALARM
RANGE
R-410a 6203-0001
6203-0002
6203-0003
500 ppm
1,000 ppm
2,000 ppm
2,000 ppm
2,000 ppm
4,000 ppm
2,500 ppm
5,000 ppm
10,000 ppm
R-407c 6203-0011
6203-0012
6203-0013
500 ppm
1,000 ppm
2,000 ppm
2,000 ppm
2,000 ppm
4,000 ppm
2,500 ppm
5,000 ppm
10,000 ppm
R-404a 6203-0021
6203-0022
6203-0023
500 ppm
1,000 ppm
2,000 ppm
2,000 ppm
2,000 ppm
4,000 ppm
2,500 ppm
5,000 ppm
10,000 ppm
R-32 6203-0041
6203-0042
6203-0043
500 ppm
1,000 ppm
2,000 ppm
2,000 ppm
2,000 ppm
4,000 ppm
2,500 ppm
5,000 ppm
10,000 ppm