RKI Instruments RX-8500 Portable Multi-Gas Monitor, 0-100% LEL & 0-100% Vol CH4 (methane calibration) / 0-40% oxygen / 0-1000 ppm CO /0-20% CO2 with Li-Ion battery and charger - 73-0620

Item #:
73-0620
Brand:
RKI Instruments
RKI Instruments RX-8500 Portable Multi-Gas Monitor, 0-100% LEL & 0-100% Vol CH4 (methane calibration) / 0-40% oxygen / 0-1000 ppm CO /0-20% CO2 with Li-Ion battery and charger - 73-0620
$3,413.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments RX-8500 Portable Multi-Gas Monitor, 0-100% LEL & 0-100% Vol CH4 (methane calibration) / 0-40% oxygen / 0-1000 ppm CO /0-20% CO2 with Li-Ion battery and charger - 73-0620

RKI Instruments RX-8500 Portable Multi-Gas Monitor, 0-100% LEL & 0-100% Vol CH4 (methane calibration) / 0-40% oxygen / 0-1000 ppm CO...

$3,413.00

RX-8500 Portable Multi-Gas Monitor, 0-100% LEL & 0-100% Vol CH4 (methane calibration) / 0-40% oxygen / 0-1000 ppm CO /0-20% CO2 with Li-Ion battery and charger

*Please note we can only ship RKI products to customers within the United States

Measuring gas
Combustible gas
(CH4)
Oxygen
(O2)
Carbon monoxide
(CO)
Carbon dioxide
(CO2)
Measuring principle
Non-dispersive infrared type
Galvanic cell type
Electrochemical type
Non-dispersive infrared type
Measuring range <service range>
0 - 100.0% LEL/ 5 - 100.0 vol%
0 - 25.0 vol% <25.1 - 40.0 vol%>
0 - 1000 ppm
0 - 20.0 vol%
Minimum resolution
0.5% LEL (0 - 100.0% LEL)
0.5 vol% (5.0 - 100.0 vol%)
0.1vol%
1ppm
0.01 vol% (0 - 2.00 vol%)
0.05 vol% (2.00 - 5.00 vol%)
0.1 vol% (5.00 - 20.0 vol%)
Concentration display LCD digital (7-segment + Symbol + Bar meter)
Sampling method Sample-drawing
Suction flow rate 0.75 L/min or more (Open flow rate)
Displays Battery level icon, pilot indicator, and pump operation status indicator
Buzzer sound volume 95 dB (A) or higher (30 cm)
Fault alarm/self diagnosis Low flow rate, battery voltage abnormalities, calibration failure, sensor abnormalities, system abnormalities and clock abnormalities.
Fault alarm display Lamp blinking, intermittent buzzer sounding, and detail display
Fault alarm pattern Self-latching
Transmission method IrDA (for data logger)
Functions LCD backlight, peak display, pump stop, data logger and log data display
Power supply Dedicated lithium ion battery unit [BUL-8000(Z1)] <standard> Or dedicated dry battery unit <AA alkaline dry battery x 3> [BUD-8000(Z)]
Continuous operating time BUL-8000(Z1): About 15 hours (25°C, no alarm, no lighting and battery fully charged) <standard>
BUD-8000(Z): About 8 hours (25°C, no alarm and no lighting) <Option>
Operating temperatures -20 - +50ºC (at a constant condition)
Operating humidities Below 95% RH (Non-condensing)
Structure Drip-proof and dust-proof performances (compliant to IP67 level)
Explosion-proof structure Intrinsically safe explosion-proof structure
Explosion-proof class Ex ia IIC T4 Ga (ATEX/IECEx<Presafe>) / Ex ia llC T4X (TIIS)
Dimensions Approx. 154 (W) x 81 (H) x 163 (D) mm (projection portions excluded)
Weight About 1.2 kg (with BUL-8000(Z1)) <standard> or about 1.1 kg (with BUD-8000(Z)) <Option>