RKI Instruments SDM-2009 Single Point Calibration Station for GX-2009 with AC Adaptor, Flash Drive, USB Cable, Tubing, Installation CD, Demand Flow Regulator & 34AL Cylinder H2S (25 ppm)/CO/CH4/O2 - 81-SDM2009-06

Item #:
81-SDM2009-06
Brand:
RKI Instruments
$1,785.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments SDM-2009 Single Point Calibration Station for GX-2009 with AC Adaptor, Flash Drive, USB Cable, Tubing, Installation CD, Demand Flow Regulator & 34AL Cylinder H2S (25 ppm)/CO/CH4/O2 - 81-SDM2009-06

RKI Instruments SDM-2009 Single Point Calibration Station for GX-2009 with AC Adaptor, Flash Drive, USB Cable, Tubing, Installation CD, Demand Flow...

$1,785.00

81-SDM2009-06 SDM-2009 Single Point Calibration Station for GX-2009 with AC Adaptor, Flash Drive, USB Cable, Tubing, Installation CD, Demand Flow Regulator & 34AL Cylinder H2S (25 ppm)/CO/CH4/O2 by RKI Instruments

RKI's new SDM-2009 calibration station for the GX-2009 is now available with advanced features for charging, calibration, & bump testing. Once you power up the GX-2009 inside the SDM-2009 calibration module, the GX-2009's display will indicate whether it's transmitting data, bump testing, calibrating, as well as the results of the bump test or calibration.

Stand Alone Station

The SDM-2009 is a versatile maintenance tool that automates the service of a GX-2009 portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).

Multi Module System

Automate how you manage and service GX-2009 instruments by connecting the SDM-2009 to a computer with a USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test, archive data, or charge up to ten instruments. Also, download the datalogging history from each instrument into one easy to manage locator. SDM-2009 stations can be manifolded together to reduce the number of demand flow regulator gas cylinders required.

Stand Alone Station Features

  • Stand-alone station (no PC Required)
  • Charging
  • Calibration
  • Bump Test
  • Save Bump Test and Calibration records
  • Bump test and calibration records copy to USB jump drive
  • Includes PC software for viewing/ archiving bump test and calibration records

Multi Module System Features

  • Multiple modules connected to a PC (10 max)
  • Charging
  • Calibration
  • Bump Test
  • Automatic calibration/bump test option
  • Configure GX-2009 parameters
  • Archive Bump Test and Calibration records
  • Archive data to network location
  • Software controlled data retrieval
  • Windows 7 compatible

*Please note we can only ship RKI products to customers within the United States

Input Power 12 VDC NOTE: AC Adapter with 100 - 240 VAC, 50/60 Hz, 0.6A input and 12 VDC, 1.2A output provided as standard.
Environmental Conditions For Indoor Use Only
-10° C to 40° C, below 80% Relative Humidity, Non-Condensing
Applicable Instruments GX-2009
Maximum Number of Records Saved 200 (stand-alone). Unlimited with software
Number of Calibration Gas Cylinders 1 Calibration gas, 1 fresh air and 1 exhaust
Standard Accessories AC Adapter
USB Flash Drive
Single Module Data Viewer Software
SDM GX Docking Station PC Controller Program
Inlet Air Filter
Instruction Manual
10 Foot Long Exhaust Tube
One 3 Foot Long Tube for GAS Fitting
2 T-Fittings (for PC Controlled Configuration only)
10 Foot Long 3/16 Inch Tube for GAS manifold ing (used for PC Controlled Configuration only)
Check Valve (used for PC Controlled Configuration only)
USB Cable, Type A to Type B

Questions & Answers