1-866-4 JJSTECH(1-866-455-7832)

RKI Instruments SDM-6000 Calibration Station for GX-6000, includes Particle Filter, Connection Brackets, SD Card, USB SD Card Reader, Ethernet Cable, USB Cable for PC, Exhaust Tubing, and Single Unit AC Adapter - 81-SDM6000-01

Item #:
81-SDM6000-01
Brand:
RKI Instruments
RKI Instruments SDM-6000 Calibration Station for GX-6000, includes Particle Filter, Connection Brackets, SD Card, USB SD Card Reader, Ethernet Cable, USB Cable for PC, Exhaust Tubing, and Single Unit AC Adapter - 81-SDM6000-01
$2,200.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments SDM-6000 Calibration Station for GX-6000, includes Particle Filter, Connection Brackets, SD Card, USB SD Card Reader, Ethernet Cable, USB Cable for PC, Exhaust Tubing, and Single Unit AC Adapter - 81-SDM6000-01

RKI Instruments SDM-6000 Calibration Station for GX-6000, includes Particle Filter, Connection Brackets, SD Card, USB SD Card Reader, Ethernet Cable, USB...

$2,200.00

81-SDM6000-01 SDM-6000 Calibration Station for GX-6000, includes Particle Filter, Connection Brackets, SD Card, USB SD Card Reader, Ethernet Cable, USB Cable for PC, Exhaust Tubing, and Single Unit AC Adapter by RKI Instruments

Stand Alone Station

The SDM-6000 is a versatile maintenance tool that automates the service of a GX-6000 portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via SD card (PC software and SD card included).

Modular Design

SDM-6000 calibration stations are modular by design and can easily connect to each other without the need of any tubes or cables. One power source and one set of calibration equipment can provide service for up to 10 SDM-6000 calibration stations.

Up to 10 calibration stations can also be connected to one PC for automated charging, calibration, bump testing and archiving of data. Even if instruments are turned off, automated routines will power up the instruments and run as scheduled. All data collected from the PC Controlled software can also be centralized in one network location accessible by anyone with the PC Controlled software with access to the network location.

Stand Alone Station Features

  • Stand-alone station (no PC Required)
  • Charge, calibrate, bump test, and alarm test
  • Included software collects calibration, bump test, alarm history, and exposure date from instruments
  • Automatically power instruments on / off for scheduled calibration
  • Accepts GX-6000 with or without rubber boot

Modular Design

  • Simultaneously bump / calibrate, charge, and collect data up to 10 instruments
  • No tubing, adaptors or wires needed to connect
  • One power source for all stations
  • Configure GX-6000 parameters
  • Centralize instrument data from multiple stations and locations to one network location
  • Ethernet port for LAN connectivity
  • Schedule automatic calibration / bump test
  • Optional valve expansion module for up to six gas cylinders
  • Optional battery operated printer

*Please note we can only ship RKI products to customers within the United States

Display Touch panel TFT liquid crystal (3.5 inch, 320×240 image element QVGA, RGB1677 million colors) Back light
LED 3 color [Green, Red, Orange]. Each status is indicated by Lighting / Blinking
BUMP test Standard setting values
AIR Flush time: 15sec
GAS time: 20sec
AIR Purge time: 5sec
Threshold value: ±50%
Auto Calibration: OFF
Auto alarm function check: ON
Auto print: OFF
Setting range
AIR Flush time: 15~120sec
GAS time: 20~120sec
AIR Purge time: 5~120sec
Threshold value: ±10~50%
Auto calibration: ON, OFF
Auto alarm function check: ON, OFF
Auto print: ON, OFF
Bump test result: Displayed on TFT liquid crystal
Calibration Standard setting values
AIR Flush time: 30sec
GAS time: 90sec
AIR Purge time: 30sec
Auto alarm function check: ON
Auto print: OFF
Setting ranges
AIR Flush time: 15~120sec
GAS time: 20~120sec
AIR Purge time: 5~120sec
Auto alarm function check: ON, OFF
Auto print: ON, OFF
Calibration result: Displayed on touch screen display
Power (AC adaptor) 100~240VAC~50/60Hz
Dimension, weight 5.11"(W) x 13"(H) x 7.2"(D) in Approx. 3.7lb
Operation temperature, humidity 0~104F, below 95~RH (no condensing)
USB printer port A type: Connects SDM-6000 printer (SII, DPU-S245) via USB cable
RJ-45 connector Ethernet port for a LAN connection
SD card slot Compatible with SD & SDHC cards
Joint connector Connecting SDM-6000 (Max 10 units) and SV-3
Inlet 4 inlets: GAS 1 / GAS 2 / GAS 3 / AIR
Certification CE marking
Standard Functions Charging, Cal. cap fitting status monitoring, Power ON function, Alarm activation check, multi language (English, German, Japanese, Korean, Russian, Portuguese, Spanish, Italian, French), backlight adjusting, buzzer function, self-diagnosis for instruments connection
Standard accessory Operating manual, filter, connecting plate, wall mount plate, PC controller software
Software PC controller software included as standard. Windows 7 & 10 compatible
Optional accessory SV-3 solenoid valve adds 3 additional calibration gas inputs
AC adaptor (15W output), AC adaptor (100W output)
Calibration Station utility software
Calibration gas & regulators
Tubing Battery powered printer

Questions & Answers


There are no questions or answers for this item.