1-866-4 JJSTECH(1-866-455-7832)

RKI Instruments SDM-E2 Stand Alone Calibration Station for Eagle 2, with AC Adaptor, Flash Drive, USB Cable, Tubing, Installation CD, Two Demand Flow Regulators, 58AL Cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 10 ppm Isobutylene in Air - 81-SDME2-08-P1

Item #:
81-SDME2-08-P1
Brand:
RKI Instruments
$2,835.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments SDM-E2 Stand Alone Calibration Station for Eagle 2, with AC Adaptor, Flash Drive, USB Cable, Tubing, Installation CD, Two Demand Flow Regulators, 58AL Cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 10 ppm Isobutylene in Air - 81-SDME2-08-P1

RKI Instruments SDM-E2 Stand Alone Calibration Station for Eagle 2, with AC Adaptor, Flash Drive, USB Cable, Tubing, Installation CD, Two...

$2,835.00

81-SDME2-08-P1 SDM-E2 Stand Alone Calibration Station for Eagle 2, with AC Adaptor, Flash Drive, USB Cable, Tubing, Installation CD, Two Demand Flow Regulators, 58AL Cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 10 ppm Isobutylene in Air by RKI Instruments

Stand Alone Calibration Station

The SDM-E2 is a versatile maintenance tool for the Eagle 2 portable gas monitor. This docking station can be used as a stand-alone device for charging, calibration and bump testing, with all records automatically stored for future upload to a PC via USB flash drive (PC software and flash drive included).

Multi Module System

The SDM-E2 can also be connected to a PC for automated calibration bump testing and archiving of datalog data from Eagle 2 instruments. Up to ten SDM-E2 docking stations can be connected simultaneously using USB cables. The SDM-E2 is also equipped with two gas ports to connect up to two calibration gas mixtures to the multi module system.

Stand Alone Station Features

  • Stand-alone station (no connection to PC Required)
  • Charging (NiMH batteries)
  • Calibration
  • Bump Test
  • Save bump test and calibration records
  • Bump test and calibration records copy to USB jump drive
  • 2 Calibration gas ports
  • Includes PC software for viewing/archiving bump test and calibration records

Multi Module System Features

  • Multiple modules connected to a PC (10 max)
  • Charging
  • Calibration
  • Bump Test
  • Configure Eagle 2 parameters
  • 2 Calibration gas ports
  • Archive Bump Test and Calibration records
  • Archive data to network location
  • Software controlled data retrieval
  • Automatic calibration/bump test option
  • Windows 7 compatible

*Please note we can only ship RKI products to customers within the United States

Input Power AC Adapter with 100 - 240 VAC, 50/60 Hz, 0.6A input and 112 VDC, 1.2A output provided as standard.
Environmental Conditions For Indoor Use Only
-10° C to 40° C, below 80% relative humidity, non condensing
Applicable Instrument Eagle 2
Maximum Number of Records Saved 200
Calibration Gas Ports Connect up to 2 calibration gas cylinders to each station
Standard Accessories AC adapter
USB flash drive
Single module data viewer software
SDM Docking station PC controller software
Inlet air filter
Instrument manual
10' exhaust tube

Questions & Answers