1-866-4 JJSTECH(1-866-455-7832)

Honeywell Analytics Satellite XT Gas Detector Transmitter, Analog, 4-20mA/C - 9602-0250

Item #:
9602-0250
Brand:
Honeywell Analytics
Honeywell Analytics Satellite XT Gas Detector Transmitter, Analog, 4-20mA/C - 9602-0250
$2,805.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Honeywell Analytics Satellite XT Gas Detector Transmitter, Analog, 4-20mA/C - 9602-0250

Honeywell Analytics Satellite XT Gas Detector Transmitter, Analog, 4-20mA/C - 9602-0250

$2,805.00

9602-0250 Satellite XT Gas Detector Transmitter, Analog, 4-20mA/C by Honeywell Analytics

The Satellite XT is the simple solution for all "Point-of-Use" gas detection needs. Based upon the market's smallest and most reliable electrochemical cell technology, the Satellite XT offers flexibility, simplicity and ease of application. The Satellite XT can be purchased in either an analog or digital configuration, allowing it to interface with new or existing facility control technologies.

The digital Satellite XT is built on LonWorks® technology. Life safety systems built on a LonWorks® network platform allow users to leverage the cost efficiencies of distributed controls, while maintaining the integrity and reliability necessary for code compliant safety applications.

The Satellite XT is an intelligent gas detection transmitter which utilizes a unique electrochemical sensor to detect toxic, corrosive, and combustible gas.

The Satellite XT is a "Point-of-Use" monitor normally located at or near a potential source of gas release. Field accessories allow sampling options for various environments including in-situ duct detection and extractive designs for harsh or remote areas. Typical installations for gas detection sampling include gas cabinet exhaust ducting, valve manifold boxes, equipment enclosures and ambient breathing zones.

Each digital Satellite XT transmitter bears a unique address for use on a LonWorks® network. This feature allows it to participate in a community of other intelligent LonWorks® devices, which when considered together, comprise a life safety system network. Gas concentration and alarm information are both displayed locally at the Satellite XT, as well as distributed onto the LonWorks® network for use by other field devices. The Satellite XT provides complete programmability of all monitoring variables including gas type, alarm levels, and maintenance status.

Applications: Provides gas detection for:

  • Gas cabinets
  • Valve manifold box
  • Equipment enclosure
  • Ambient breathing zone
  • Gas storage rooms
  • OEM equipment

Advantages:

  • Fast, reliable, specific gas detection
  • Continuous real-time monitoring
  • Interchangeable intelligent sensor cell
  • No dynamic gas calibration required
  • Generic sensor head electronics
  • Low cost of ownership
  • No moving parts to wear down or replace
   
Satellite XT 4-20 mA
Satellite XT 4-20 mA/R
Satellite XT4-20 mA/C
Power requirements Voltage
12 to 24 VDC
12 to 24 VDC
12 to 24 VDC
Consumption
max. 1W
max. 1.8W
max. 1.4W
Analog Signal Output Monitoring mode
42-20mA
4-20mA
4-20mA
Warning condition
2.8-4 mA 0.1Hz
2.8-4 mA 0.1Hz
2.8-4 mA 0.1Hz
Maintenance mode
2.4-4 mA 1Hz
2.4-4 mA 1Hz
2.4-4 mA 1Hz
Fault range
0-2mA
0-2mA
0-2mA
Wiring Analogue interface
3-wire shielded cable 3x1.0mm2/ 17 AWG (approx. 2m delivered with instrument)
3-wire shielded cable 3x1.0mm2/ 17 AWG (approx. 2m delivered with instrument)
3-wire shielded cable 3x1.0mm2/ 17 AWG (approx. 2m delivered with instrument)
Relay contacts
6-wire shielded cable 6x0.25mm2/23 AWG (approx. 3m delivered with instrument)
Relay outputs Contacts
3 x SPST (Single-Pole Single-Throw)
Max. ratings
250 VAC / 30 VDC, 2A
Graphic display  
122 x 32 dots with backlight
122 x 32 dots with backlight
122 x 32 dots with backlight
Status LED  
Green
Green
Green
Keypad  
6 touch-sensitive membrane function keys
6 touch-sensitive membrane function keys
6 touch-sensitive membrane function keys
Physical dimensions LxWxD Size
145 x 95 x 50mm
5.7" x 3.7" x 2.0"
145 x 95 x 50mm
5.7" x 3.7" x 2.0"
145 x 95 x 50mm
5.7" x 3.7" x 2.0"
Weight
480g (17oz)
650g (23oz)
520g (18oz)
Mounting  
Special mounting plate (delivered with instrument)
Special mounting plate (delivered with instrument)
Special mounting plate (delivered with instrument)
Housing protection class IP 52 (option: IP 65)
IP 52 (option: IP 65)
IP 52 (option: IP 65)
IP 52 (option: IP 65)
RFI / EMC  
EN 55011
EN 50082-2
EN 55022
EN 50082-2
EN 55011
EN 50082-2
Operating conditions Temperature
-20°C up to +40°C
-4°F up to +104°F
-20°C up to +40°C
-4°F up to +104°F
-20°C up to +40°C
-4°F up to +104°F
Pressure
700 up to 1300hPa
700 up to 1300hPa
700 up to 1300hPa
Humidity
20 up to 90% r.h.
20 up to 90% r.h.
20 up to 90% r.h.
Part number
9602-0200
9602-0205
9602-0250

Questions & Answers