1-866-4 JJSTECH(1-866-455-7832)

Kanomax S500 Monitor with Lithium Battery (Sensor is not included)

Item #:
S500
Brand:
Kanomax
Kanomax S500 Monitor with Lithium Battery (Sensor is not included)
Add to cart to see price
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Kanomax S500 Monitor with Lithium Battery (Sensor is not included)

Kanomax S500 Monitor with Lithium Battery (Sensor is not included)

Add to cart to see price

Discontinued


S500 Monitor with Lithium Battery (Sensor is not included) by Kanomax

Providing high level of functionality and monitoring capability, the Aeroqual Series can be used portably or fixed in position. The monitor is compatible with the full range of Aeroqual gas sensors. The remote sensor head adaptor kit is designed to allow the sensor head to be located up to 46 ft away from the main unit.

Applications :

  • IAQ Investigation
  • Industrial Hygiene Quality Control
  • Occupational Safety and Health Testing
  • US GBC LEED certification

Features :

  • Interchangeable sensor heads capable of measuring more than 20 types of toxic gases
  • Remote sensor capability
  • Alarm and Analog output available
Monitor Base Specification

Measurement units ppm or mg/m3
Sensor Head Removable and Replaceable
Reading Functions Minimum / Maximum / Average / 15-min
Functions On-board alarm
Alarm status displayed
Alarm mute function
Low battery indication
Sensor condition status
Stand-by mode
Remote sensor capability
Data logging and transfer data to PC
On-board real-time clock
Alarm output Transistor output, 150 mA max
Low alarm, High alarm & Control
Analog output 0 to 5 V
Digital output USB
On-board Data Logging 8188 data points
Power Supply Li-Ion Battery (lasts up to 8 hrs) or AC Adapter
Battery Type Lithium Polymer
Enclosure Rating IP20 & NEMA 1 equivalent
Dimensions (with sensor head) 7.0 x 4.75 x 2.0 inches (195 x 122 x 54 mm)
Weight (with sensor & battery) < 16 oz (460 g)
Approvals Part 15 of FCC Rules
EN 50082-1: 1997
EN 50081-1: 1992

Sensor Specifications:

Gas Sensor Heads
Range (ppm)
Accuracy
Resolution
Ammonia
0 - 100
± 5 ppm
0.1 ppm
Ammonia (leak)
0 - 1000
± 15%
1 ppm
Carbon monoxide
0 - 100
±5 ppm
0.1 ppm
Carbon monoxide
0 - 1000
±10%
1 ppm
Carbon dioxide
0 - 2000
±40 ppm + 3%
10 ppm
Carbon dioxide
0 - 5000
±150 ppm + 5%
10 ppm
Formaldehyde
0 - 10
±10%
0.01 ppm
Hydrogen
0 - 5000
±10 %
1 ppm
Hydrogen sulphide
0 - 10
±0.5 ppm
0.01 ppm
Methane
0 - 9999
±15 %
1 ppm
Ozone
0 - 0.150
±0.005 ppm
0.001 ppm
Ozone
0 - 0.500
±0.008 ppm
0.001 ppm
Nitrogen dioxide
0 - 1
±0.001 ppm
0.001 ppm
NMHC 3,4
0 - 25
±10 %
0.1 ppm
Perchloroethylene
0 - 200
±5 ppm
1 ppm
Sulphur dioxide
0 - 10
±0.5 ppm
0.01 ppm
VOC
0 - 25
±10 %
0.1 ppm
VOC
0 - 500
±10 %
1 ppm
Temperature
-40 - 124°C
-
-
Relative Humidity
0 - 100%RH
-
-

Multi-Gas Sensor Head Specifications:

Multi-Gas Sensor Heads
Sensor
Range (ppm)
Accuracy
Resolution
MS1
CO2
CO
0-2000
0-100
± 40 ppm + 3%
± 10%
1 ppm
0.1 ppm
MS2
CO2
CO
VOC (PID)
0-2000
0-100
0-25
± 40 ppm + 3%
±10%
± 10%
1 ppm
0.1 ppm
0.01 ppm

Questions & Answers


There are no questions or answers for this item.