1-866-4 JJSTECH(1-866-455-7832)

Casella Environmental Sound Level Meter Type 2 with Standard Accessories

Item #:
CEL-631-C2
Brand:
Casella
Casella Environmental Sound Level Meter Type 2 with Standard Accessories
$3,495.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Casella Environmental Sound Level Meter Type 2 with Standard Accessories

Casella Environmental Sound Level Meter Type 2 with Standard Accessories

$3,495.00

Discontinued


CEL-631-C2 Environmental Sound Level Meter Type 2 with Standard Accessories by Casella

While many industrial hygiene professionals are interested in noise measurements inside the workplace there is also an increasing demand to measure environmental noise outdoors as well. The CEL-631 environmental noise analyzer has been designed to satisfy this need by providing overall data storage of varying noise levels during the day. The comparison of the different LN% values is useful in describing the variability of the noise over time. A super wide 120 dB dynamic range means that the user does not need to worry about selecting scales as the meter will always be on the right range. The provision of all the popular frequency & time weightings and exchange rates allow many different noise measurements to be taken by new and experienced users alike. The CEL-631 has a full-color, graphic LCD for complete clarity.

Key Benefits

  • Wide dynamic range from 20 to 140 dB on single span
  • A, C and Z simultaneous frequency weightings
  • Slow, Fast and Impulse rms. simultaneous time responses
  • Q=3, Q=4 and Q=5 simultaneous exchange rates
  • Large 240 x 320 pixel color ¼ VGA graphic display
  • Easy to use menu structure
  • Storage of complete overall run results inc. 5 x LN%
  • Manual or fixed duration recording possible
  • Available in ANSI/IEC class 1 and class 2 accuracy
  • Available as B or C version with real time octave & 1/3 octave band
  • Storage of all results simultaneously in a huge non-volatile memory
  • Up to 999 runs stored
  • Available as complete measurement kits with acoustic calibrator and case

Applications

For measurements of many industrial noise levels the time average sound pressure level is often adequate. However, in many situations noise levels are variable or changing too quickly to accurately estimate the background level over a representative time period. The CEL-631 is designed to assist in the correct interpretation of these non-steady noise climates by including the percentile noise levels that have occurred during the run. The changing noise levels are sampled and the various percentile values such as the LN10%, LN50% and LN90% are calculated. This enables the CEL-631 to correctly record the key maximum, minimum, time average and 5 x percentile noise levels for comparison with national or international limits. Additionally, octave and third octave band filters in the B and C versions of the CEL-631 provide real time frequency analysis of tonal noise levels that are important for the correct prescription of hearing protectors or noise reduction applications such as barriers or earth bunds.
Technical Specification - General
Accuracy ANSI S1.4 & S1.43, IEC 61672-1 2002-5
Frequency filters comply with ANSI S1.11 and IEC 61260
Microphone type ½” Free field Electret microphone & preamplifier
Type 1 or Type 2 on a removable CEL-495 preamplifier
Reference Conditions 68°F (20°C) air temperature
65% Relative Humidity
1013 mbar (101.325 kPa) atmospheric pressure
Operating Temperature Range 14 to 122°F (-10 to 50°C) (Class 1)
32 to 104°F (0 to 40°C) (Class 2)
Effect of Humidity Less than ±0.5dB over the range 30 to 90% RH (non-condensing), rel. to value at ref. conditions
Operating pressure range 650 to 1080 mbar (65 to 108 kPa)
Batteries 3 x AA Alkaline or NiMH rechargeable types
Battery Life (hours) Up to 12 hours without backlight
Dimensions w x h x d (in/mm) 2.8 x 10.5 x 1.2 in (71.5x 267.0x 31.0mm) including preamplifier and microphone
Weight including batteries (oz/gm) 10.1 oz (< 291g)
Tripod socket for fixed measurements Yes via standard camera thread (1/4” size)
Operator controls 8 buttons for power On/Off + 2 x context sensitive menu selection + 4 navigation + confirm selection
Technical Specification – Performance
Total measurement range (dB) 20 to 140
Dynamic range on single measurement span (dB) 120
Noise floor (A weighted dB) < 20 (Class 1), < 25 (Class 2)
Frequency weightings Simultaneous A, C & Z (unweighted)
Time weightings Simultaneous Slow, Fast and Impulse
Amplitude weightings (Exchange rate) Simultaneous Q=3, Q=4 and Q=5 dB
Displayed parameters available as per user selected list or using pre-configured setups Lp, Lmx, Lmn, Lpk
Leq, LIeq, LDOD, Lavg, LAE, Ltm3, Ltm5
4 fixed LN% values plus 1 user selectable % value
Narrow band real time measurements (B version) 11 octave bands 16 Hz to 16 kHz
(C version) 33 third octave bands 12.5 Hz to 20 kHz with cursor readout plus A & C & Z broad band levels
Display of octave and third octave band levels Graphical spectrum including broad band values
With listing of individual band levels in tabular format
Measurements in octave (& 1/3) band mode include Lmx and Leq with selected freq and time weightings
Plus 5 LN% spectra
Display type 240 x 320 full color dot matrix LCD digital including real-time analog bar graph scale
Data storage 1 Gb internal memory 999 run maximum memory storing all parameters over the whole of the run – overall results are recorded
Direct printing of results on site To portable battery operated printer on 3 in paper roll
Displayed time span for time history graph on LCD Last 60 seconds
Signal detected when calibrator placed over microphone at 1 kHz frequency Calibration level set to 114.0 or 94.0 dB
With +/-1 dB span and 0.1 dB resolution by user
External power option (12 Vdc) or via USB 5V line Yes via universal CEL-PC18 unit
Analog outputs AC (and optional DC) via 2.5 mm jack socket
AC output characteristics - (Provided for DAT tape / PC wav file recording or headphone applications) Approx 0.85V RMS FSD output on selected sound level measurement range.
Minimum load impedance 22k.
DC output characteristics - (Provided at time of order as option for connection to chart recorder or pc data logging system) 0 to 1.3V DC for FSD on selected range.
Output corresponds to selected frequency and time weighting. 2k Output impedance
Digital output of stored result sets Via USB 2.0 mini B connector to Casella Insight program
Audio recording Voice notes can be stored at the start of a run in wav file format for later identification and annotation

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.