1-866-4 JJSTECH(1-866-455-7832)

Extech AN320 Large Vane CFM/CMM Anemometer/Psychrometer + CO2 with Limited NIST

Item #:
EXT-AN320-NISTL
Brand:
Extech
Extech AN320 Large Vane CFM/CMM Anemometer/Psychrometer + CO2 with Limited NIST
$809.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech AN320 Large Vane CFM/CMM Anemometer/Psychrometer + CO2 with Limited NIST

Extech AN320 Large Vane CFM/CMM Anemometer/Psychrometer + CO2 with Limited NIST

$809.00

Discontinued


AN320 Large Vane CFM/CMM Anemometer/Psychrometer + CO2 with Limited NIST by Extech

Extech's 4" (10cm) Large Vane Thermo-Anemometer series allows for more precise readings on larger size ducts. Each meter simultaneously displays Airflow or Air Velocity and Temperature. Choose models that also measure Air Volume, Humidity & Carbon Dioxide (CO2).

Features

  • Measures Relative Humidity, Wet Bulb and Dew Point
  • Carbon Dioxide (CO2) measurement
  • Built-in thermistor for air temperature
  • Multipoint and timed average calculations
  • Min/Max, Data Hold, and Auto power off
  • Optional Air Flow Cone Kit (AN300-C): 8.26" (210mm) round and 13.6" (346mm) square
  • Complete with four AAA batteries and hard case

Applications

  • HVAC
  • Manufacturing
  • Engineering
  • Appliance Testing
  • Research and Design
General Specifications
Circuit Custom LSI microprocessor
Display Dual function 13 mm (0.5") 4 - digit LCD
Sampling rate 1 reading per second approx.
Air velocity/flow sensor Conventional angled vane arms with low - friction ball bearing
Temperature Sensors NTC - type precision thermistors
CO2 Sensor NDIR CO2 sensor
Automatic Power off Auto shut off after 20 minutes to preserve battery life (sleep mode)
Operating Temperature 0°C to 50°C (32°F to 122°F)
Storage Temperature -10°C to 50°C (14 to 122°F)
Operating Humidity <80% RH
Storage Humidity <90% RH
Operating Altitude 2000 meters (7000ft) maximum
Battery Power Four (4) 'AAA' 1.5V batteries
Battery Life > 40 hours
Battery consumption 8.3 mA DC (approx.)
Weight 725g (1.6 lbs.) including battery and probe
Dimensions Main instrument: 269 x 106 x 51mm (10.6 x 4.2 x 2")
Vane inner diameter: 100mm / 3.94 inches
Optional Air Flow Adaptors:
Round: 210mm (8.3") Diameter
Square: 346 x 346mm (13.6 x 13.6")

Range Specifications
Air Velocity
m/s (meters per second) Range: 0.2 - 30 m/s
Resolution: 0.01 m/s
Accuracy: ± (1.5% rdg + 0.3 m/s)
fpm (feet per minute) Range: 40 - 5900 fpm
Resolution: 1 fpm
Accuracy: ± (1.5% rdg + 59 fpm)
Relative Humidity
RH Range: 0.1%‐99.9%RH
Resolution: 0.1 RH
Accuracy: ±3%RH (10‐90%RH); ±5%RH (<10% or >90%)
Air Flow
CMM (cubic meters/min) Range: 0 - 99999 m3 /min
Resolution: 0.1 up to 9999.9 then 1.0
Area Range: 0 to 99999cm2
CFM (cubic ft/min) Range: 0 - 99999 ft3 /min
Resolution: 0.1 up to 9999.9 then 1.0
Area Range: 0 to 99999in2
Temperature
°F/°C Air and Wet Bulb Range: -20 to 60°C (-4 to 140°F)
Dew Point Range: ‐5 to 60°C (23 to 140°F)
Resolution: 0.1°C(°F)
Accuracy: ±0.6°C (-20 to 50°C); ±1.2°C (51 to 60°C); ± 1.1°F (‐5 to 122°F); ± 2.2°F (123 to 140°F)
CO2
PPM (parts per million) Range: 0 - 9999 ppm (readings over 5000 are not specified)
Resolution: 1 ppm
Accuracy: ± (30ppm + 5% of rdg) from 0 to 5000ppm

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.