Features

  • Checks for Carbon Dioxide (CO2) concentrations
  • Maintenance free dual wavelength NDIR (non-dispersive infrared) CO2 sensor
  • Measurement ranges: CO2: 0 to 6,000ppm; Temperature: -4 to 140°F (-20 to 60°C); Humidity: 10 to 95%RH
  • Continuous (20,000 sets) or manual (99 sets) datalogging
  • Data hold, Max/Min with Time stamp, and Alarm
  • Easy calibration in fresh air
  • Complete with (6) AAA batteries, RS-232 cable, and Windows® 95/98/NT/2000/ME/XP compatible softwar

Applications

  • Check air quality in schools, office buildings, greenhouses, hospitals and anywhere that high levels of carbon dioxide are generated
General Specifications
Display Three Tier LCD
Display Rate One reading per second
Low Battery Indication The Battery icon is displayed when the battery voltage drops below the operating voltage
Power Supply Six (6) AAA-size alkaline batteries or AC adapter
Battery Life Approx. 8 hours using alkaline batteries (with backlight and Alarm functions OFF)
Manual Data Memory Capacity 99 sets
Auto Datalogging Capacity 20,000 sets (maximum 99 blocks)
Operating Temperature Range 5°C to 50°C (41°F to 122°F)
Storage Temperature Range -10°C to 60°C (-14°F to 140°F)
Operating Humidity Range 10%RH to 90%RH, non-condensing
Storage Humidity Range 10%RH to 90%RH, non-condensing
Dimensions 158 (L) x 72(W) x 35(H) mm (6.22" x 2.83" x 1.38")
Weight 255g (0.56 lbs) approx. (including batteries)
Accessories Instruction Manual, Batteries, AC Adaptor, Software CD ROM, and PC Interface Cable

CO2 Specifications
Sensing Range 0 to 6000ppm
Sensing Resolution 1ppm
Accuracy ±3% of reading or ±50ppm, whichever is greater @ 101.4 kPa (29.92 inHg) and @ 25°C (77°F)
Sensing Method Dual wavelength detector with non- dispersive infrared (NDIR) sensor
Gas Sampling Mode Diffusion type
Warm up time 10 seconds
Response time < 10 minutes in still air
Temperature Coefficient Add ±0.36% of reading per °C (±0.2% of reading per °F) when deviating from calibration temperature

Temperature & Humidity Specifications
Relative Humidity
Temperature
Range
10% ~ 95% RH
20°C ~ +60°C (-4°C ~ +140°F)
Resolution
0.1% RH
0.1°C (0.1°F)
Accuracy
±3%RH @ 25°C(77°F), 30~95%RH)
±5%RH @ at 25°C(77°F), 10~30%RH)
±0.5°C (±0.9°F)
Sensor type
Precision capacitance sensor
Thermistor
Response time
45%RH→95%RH≦1min
95%RH→45%RH≦3min