EX230 12 Function Mini Digital MultiMeter with IR Thermometer and Limited NIST by Extech

Features

  • Large backlit dual LCD with easy-to read digits
  • Low current capability
  • Input fuse protection
  • Auto power off and Data Hold
  • Complete with test leads, general purpose bead wire temperature probe (Model EX230), and 9V battery
  • 4000 counts
  • 6:1 Distance to Target Ratio
  • Advanced functions include Type K Temperature, Capacitance, Frequency, and Duty Cycle
  • Relative Mode
General Specifications
Enclosure Double molded
Diode Test Test current of 0.9mA maximum, open circuit voltage 2.8V DC typical
Continuity Threshold 20 to 100Ω, test current <1.5mA
Input Impedance 10MΩ VDC/VAC
AC Response Average responding
ACV Bandwidth 40Hz to 1000Hz
IR Spectral response 6 to 16µm
IR Emissivity 0.95 fixed
IR distance ratio 6:1
Laser pointer Class 2 laser < 1mW power; Wavelength is 630 to 670nm
Display 4000 count backlit liquid crystal display
Overrange indication "OL" is displayed
Auto Power Off 30 minutes (approximately)
Polarity Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate 2 times per second, nominal
Battery One 9 volt (NEDA 1604) battery
Fuses mA, µA ranges; 500mA 250V ceramic fast blow
A range; 10A 600V ceramic fast blow
Operating Temperature -10°C to 40°C (14°F to 122°F)
Storage Temperature -10oC to 60oC (14oF to 140oF)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 2000 meters (7000 ft) maximum
Weight 260 g (9.17oz)
Size 147x76x42 mm (5.8x2.9x1.6")
Safety This meter is intended for origin of installation use and provides user protection through double insulation per IEC/EN 61010- 1:2001 and IEC/EN 61010-031:2002 to Category III 600V; Pollution Degree 2.
Approvals CE, ETL

Range Specifications
Function
Range
Resolution
Accuracy
DC Voltage
400 mV
0.1 mV
±(0.8% reading + 6 digits)
4V
0.001V
±(0.5% reading + 2 digits)
40V
0.01V
400V
0.1V
±(0.8% reading + 2 digits)
600V
1V
AC Voltage
400 mV
0.1 mV
±(1.0% rdg + 6 digits)
4V
0.001V
40V
0.01V
400V
0.1V
600V
1V
Note: All AC voltage ranges are specified from 5% of range to 100% of range
DC Current
400 μA
0.1 μA
±(1.5% reading + 5 digits)
4000 μA
1 μA
40 mA
0.01 mA
400 mA
0.1 mA
4.000
0.001 A
±(2.5% reading + 5 digits)
10 A
0.01 A
Note: 10A for 30 sec max
AC Current
400 μA
0.1 μA
±(1.5% rdg + 5 digits)
4000 μA
1 μA
40 mA
0.01 mA
400 mA
0.1 mA
4.000
0.001 A
±(3.0% reading + 5 digits)
10 A
0.01 A
Note: 10A for 30 sec max
Resistance
400 Ω
0.1 Ω
±(0.8% reading + 5 digits)
4 kΩ
0.001 kΩ
±(0.8% reading + 2 digits)
40 kΩ
0.01 kΩ
400 kΩ
0.1 kΩ
4 MΩ
0.001 MΩ
±(2.5% reading + 8 digits)
40 MΩ
0.01 MΩ
Capacitance
40.00 nF
10 pF
±(5.0% reading + 7 digits)
400.0 nF
0.1 nF
4.000 µF
1 nF
40.00 µF
10 nF
100.0 µF
0.1 µF
Note: Auto ranging; Input protection 600Vdc and AC rms
Frequency
5.000 Hz
0.001Hz
±(1.0% reading + 3 digits)
50.00 Hz
0.01 Hz
500.0 Hz
0.1 Hz
5.000 kHz
1 Hz
50.00 kH
10 Hz
500.0 kHz
100Hz
5.000 MHz
1kHz
±(1.2% reading + 4 digits)
10.00 MHz
10kH
Notes: Sensitivity: >0.5V rms (≤1MHz); >3V rms (>1MHZ); Input protection: 600V dc or ac rms
Duty Cycle
0.1 to 99.9%
0.1%
±(1.2% reading + 2 digits)
Notes: Pulse width: >100 µS <100ms; Frequency: 5Hz to150kHz; Sensitivity: <0.5V rms; Overload protect: 600V dc or ac rms
Temperature
-4 to + 1400°F
0.1°F
±(3.0% reading +9°F)
-20 to +760°C
0.1°C
±(3.0% reading + 5°C)
Sensor: Thermocouple type 'K'; Overload protection: 600V dc or ac rms
Temperature IR
-20 to 0°C
0.1°C/°F
±4°C
0 to 93°C
±(2.0%rdg or 2°C)
93 to 230
±(3.0%rdg or 3°C)
-5 to 32°F
± 8°F
32 to 200°F
±(2.0%rdg or 4°F)
200 to 446°F
±(3.0%rdg or 6°F)