1-866-4 JJSTECH(1-866-455-7832)

Extech EX310 9 Function Mini MultiMeter + Non-Contact Voltage Detector with NIST

Item #:
EXT-EX310-NIST
Brand:
Extech
Extech EX310 9 Function Mini MultiMeter + Non-Contact Voltage Detector with NIST
$114.99
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech EX310 9 Function Mini MultiMeter + Non-Contact Voltage Detector with NIST

Extech EX310 9 Function Mini MultiMeter + Non-Contact Voltage Detector with NIST

$114.99

Discontinued


EX310 9 Function Mini MultiMeter + Non-Contact Voltage Detector with NIST by Extech

Features

  • 0.5% basic accuracy
  • Built-in non-contact AC Voltage Detector with red LED indicator and audible beeper
  • Large 1" digits make it easy to read
  • Low battery indicator
  • Complete with stand, test leads, protective holster, batteries, general purpose bead wire temperature probe (Model EX330)
  • Manual ranging
General Specifications
Diode Test Bias voltage: 2.3VDC
Continuity Check Audible signal will sound if the resistance is less than 100 Ω
Input Impedance 1MΩ (VDC & VAC)
AC Bandwidth 50 / 60Hz
Display 2000 count (0 to 1999 digits) backlit LCD
Overrange indication "1__" is displayed
Polarity Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate 2 times per second, nominal
Low Battery Indication Battery symbol is displayed if battery voltage drops below operating voltage
Battery One (1) 9V battery
Fuses mA range; 200mA/250V fast blow
A range; 10A/250V fast blow, ceramic
Operating Temperature 32°F to 122°F (0°C to 50°C)
Storage Temperature -4°F to 140°F (-20°C to 60°C)
Operating Humidity Max 70% up to 87°F (31°C) decreasing linearly to 50% at 122°F (50°C)
Storage Humidity <80% RH
Operating Altitude 7000 ft. (2000 meters) maximum.
Weight 9.17 oz (260g) includes holster
Size 5.8" x 2.9" x 1.6" (147 x 76 x 42mm) includes holster
Approvals CE, UL
Safety This meter is intended for indoor use and protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001) to CAT II 1000V & CAT III 600V; Pollution Degree 2. The meter also meets UL 61010-1, Second Edition (2004), CAN/CSA C22.2 No. 61010-1, Second Edition (2004), and UL 61010B-2-031, First Edition (2003)

Range Specifications
Function
Range
Resolution
Accuracy
Non-contact AC Voltage detector
100 to 600V
Resolution & accuracy do not apply since the meter does not display the voltage in this mode. The lamp at the top of the meter’s display flashes when voltage is sensed and an audible warning will sound
DC Voltage
(V DC)
200mV
0.1mV
±(0.5% reading + 2 digits)
2000mV
1mV
±(1.0% reading + 2 digits)
20V
0.01V
200V
0.1V
600V
1V
±(1.5% reading + 2 digits)
AC Voltage (VAC) 50/60Hz
200V
0.1V
±(1.5% reading + 3 digits)
600V
1V
±(2.0% reading + 4 digits)
DC Current (A DC)
200mA
0.1mA
±(1.5% reading + 2 digits)
10A
0.01A
±(2.5% reading + 5 digits)
AC Current (A AC) 50/60Hz
200mA
0.1mA
±(1.8% reading + 5 digits)
10A
0.01A
±(3.0% reading + 7 digits)
Resistance
200Ω
0.1Ω
±(1.2% reading + 4 digits)
2000Ω
±(1.2% reading + 2 digits)
20kΩ
0.01kΩ
200kΩ
0.1kΩ
2000kΩ
1kΩ

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.