- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Draeger
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- IGD
- mPower
- MSA
- RAE Instruments
- RKI Instruments
- WatchGas
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech EX410 8 Function Professional MultiMeter with NIST
Item #:
EXT-EX410-NIST
Brand:
Extech
Share this product:
EX410 8 Function Professional MultiMeter by Extech
Features
- Large backlit LCD display with easy-to-read 1" digits
- Type K thermometer built-in for temperature measurements
- Low current capability: measure down to 0.1?A
- Input fuse protection and mis-connection warnings
- Complete with CAT III test leads, multi-position tilt stand and velcro strap for hanging, protective holster with test lead holder, bead wire temperature probe, and 9V battery
- True RMS (EX411)
- Manual Ranging
| Diode Test | Test current of 1mA maximum, open circuit voltage 2.8V DC typical |
| Continuity Check | Audible signal will sound if the resistance is less than 150 Ω |
| Input Impedance | 10MΩ |
| AC Response | Average responding |
| ACV Bandwidth | 50Hz to 1kHz |
| DCA voltage drop | 200mV |
| Display | 3 ½ digit, 2000 count LCD, 0.9" digits |
| Auto Power Off | Meter switches OFF after 15 minutes (approximately) of inactivity |
| Overrange indication | "1" is displayed |
| Polarity | Automatic (no indication for positive); Minus (-) sign for negative |
| Measurement Rate | 2 times per second, nominal |
| Low Battery Indication | Battery symbol is displayed if battery voltage drops below operating voltage |
| Battery | One 9 volt (NEDA 1604) battery |
| Fuses | mA, µA ranges; 0.2A/250V fast blow A range; 20A/250V ceramic fast blow |
| Operating Temperature | 5°C to 40°C (41°F to 104°F) |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
| Operating Humidity | Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F) |
| Storage Humidity | <80% |
| Operating Altitude | 2000 meters.(7000ft) maximum |
| Weight | 342g (0.753lb) (includes holster). |
| Size | 187 x 81 x 50mm (7.36" x 3.2" x 2.0") (includes holster) |
| Safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V and Category II 1000V, Pollution Degree 2. |
Function |
Range |
Resolution |
Accuracy |
|
DC Voltage (V DC) |
200mV |
0.1mV |
±(0.3% reading + 2 digits) |
|
2V |
0.001V |
±(0.5% reading + 2 digits) |
||
200V |
0.1V |
|||
1000V |
1V |
±(0.8% reading + 2 digits) |
||
AC Voltage (V AC) |
50 to 400Hz |
400Hz to 1kHz |
||
2V |
0.001V |
±(1.0% reading +6 digits |
±(2.0% reading + 8 digits |
|
200V |
0.1V |
±(1.5% reading +6 digits) |
±(2.5% reading +8 digits) |
|
750V |
1V |
±(2.0% reading +6 digits) |
±(3.0% reading +8 digits) |
|
DC Current (A DC) |
200μA |
0.1μA |
±(1.5% reading + 3 digits) |
|
200mA |
0.1mA |
|||
20A |
0.01A |
±(2.5% reading + 3 digits) |
||
AC Current (A AC) |
50 to 400Hz |
400Hz to 1kHz |
||
200mA |
0.1mA |
±(1.8% reading +8 digits) |
±(2.5% reading +10 digits) |
|
20A |
0.01A |
±(3.0% reading +8 digits) |
±(3.5% reading +10 digits) |
|
Resistance |
200Ω |
0.1Ω |
±(0.8% reading +4 digits) |
|
2000Ω |
1Ω |
±(0.8% reading +2 digits) |
||
20kΩ |
0.01kΩ |
±(1.0% reading +2 digits) |
||
200kΩ |
0.1kΩ |
|||
20MΩ |
0.01MΩ |
±(2.0% reading +5 digits) |
||
Temperature |
-20 to 750°C |
1°F |
±(3.0% reading +3 digits) (meter only, probe accuracy not included) |
|
-4 to 1382°F |
1°C |
|||