1-866-4 JJSTECH(1-866-455-7832)

Fieldpiece Digital Vacuum Micron Gauge Accessory Head - AVG2

Item #:
FP-AVG2
Brand:
Fieldpiece
Fieldpiece Digital Vacuum Micron Gauge Accessory Head - AVG2
$122.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Fieldpiece Digital Vacuum Micron Gauge Accessory Head - AVG2

Fieldpiece Digital Vacuum Micron Gauge Accessory Head - AVG2

$122.00

Discontinued


AVG2 Digital Vacuum Micron Gauge Accessory Head by Fieldpiece

The Fieldpiece Digital Vacuum Gauge Accessory, model AVG2, is a thermistor based digital multimeter accessory that digitally measures a vacuum of 50 to 2000 microns and converts that reading into millivolts DC on your compatible DMM or our electronic handle and data logger. LEDs provide a pump down indicator showing progress from atmospheric pressure. The sensor has been designed to withstand pressures up to 500 psi (3400kPa) so that no damage to the AVG2 will occur if it is exposed to full system pressures.

Designed for HVAC/R, the Digital Vacuum Gauge Accessory, model AVG2, gives technicians an accurate results in a compact design. Other features and benefits include:

  • Displays pressure in microns in steps of 1 micron
  • Range: 50 to 2000 microns of mercury (50 - 4000 if meter has millivolt range)
  • Resolution: 1 micron of mercury
  • Pump down indication: when pumping down from atmospheric pressure to 2000 microns, output of head goes from over 3VDC to 2VDC
  • Straight-in access to sensor for easy cleaning
  • Fitting: 1/4" flared brass fitting (male)
  • Accuracy (@~75°F): ±10%, 0-1000 microns of mercury
  • Auto-off can be disabled for data logging
  • "T" for inline vacuum testing

Includes

  • Digital Vacuum Gauge Accessory - AVG2
  • 9V Battery (installed)
  • Operator's Manual
Sensor Precision thermistor
Fitting Standard 1/4 flared brass fitting (male)
Conversion rate 1 mVDC/1 micron of mercury
Range 50 to 2000 microns of mercury
Resolution 1 micron of mercury
Accuracy ±10% or ±10 microns, (50 to 1000 microns) @ 73°F ±9°F (23°C ±5°C), <90%RH.
Operating environment 32 to 122°F (0 to 50°C) @ <75%RH
Storage environment -4 to 140°F (-20 to 60°C) @ <80%RH with battery removed
Pump down indication When pumping down from atmospheric pressure to 2000 microns, output of head goes from over 3VDC to 2VDC.
Overload 500psi (3400kPa)
Battery 9V
Battery life 35 to 40 hours typical (alkaline). Red LED indicates battery is below operating level.
Auto-off To extend battery life, the AVG2 automatically turns off after 5 minutes when reading above 70,000 microns. The auto-off switch is located beneath the rubber covering. Use it to disable auto-off function.

Questions & Answers


There are no questions or answers for this item.