1-866-4 JJSTECH(1-866-455-7832)

Fieldpiece Manual and Auto Ranging Digital Multimeter - HS35

Item #:
FP-HS35
Brand:
Fieldpiece
Fieldpiece Manual and Auto Ranging Digital Multimeter - HS35
$247.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Fieldpiece Manual and Auto Ranging Digital Multimeter - HS35

Fieldpiece Manual and Auto Ranging Digital Multimeter - HS35

$247.00

Discontinued


HS35 Manual and Auto Ranging Digital Multimeter by Fieldpiece

The HS35 manual and auto ranging multimeter includes the tests you use everyday for HVACR field service. Like the rest of the HS30 series, the HS35 works with all of our accessory heads. It comes equipped with a magnetic hanger, detachable silicone test leads and alligator clip probe tips for remote and easy one-handed testing, as well as the full set of built-in safety features. Built-in temperature with excellent compensation and capacitance ranges are a big plus.

The removable tip test leads and alligator probe extensions make safe one-handed testing a snap. The k-type thermocouple port on the front of the meter allows you to test a number of HVAC parameters right from your multimeter. And it's packed with the features HVACR professionals need:

  • Non-contact Voltage
  • High Voltage and Continuity Indicators
  • Microamps DC for flame diodes
  • Capacitance
  • MIN/MAX
  • Temperature
  • Rugged ABS case with rubberized bumpers
  • Built-in magnetic hanger allows you to test with one hand or no-hands
  • Built-in lead storage
  • Ergonomic shape fits naturally in your hand
  • Auto power-off (APO) to conserve battery life

Includes

  • Expandable Auto Ranging Stick Multimeter - HS35
  • 400A Amp Clamp Accessory - ACH4
  • Deluxe Silicone Test Leads - ADLS2
  • Short Alligator Lead Extensions - ASA2
  • Deluxe Meter Case - ANC1
  • 9-Volt Battery (installed)
  • Operator's Manual
General Specification
Display 3¾ digit liquid crystal display (LCD) with a maximum reading of 3999.
Analog bar graph 41 segments with measurements 20 times per second .
Range (RNG) Manual ranging mode (HS35)
Overrange "OL" mark indication.
Auto power off 30 minutes.
Operating environment 32 to 122°F (0 to 50°C) at <70% R.H.
Storage temperature -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed.
Accuracy Specification good in ambient conditions of 73°F ± 9°F (23°C ±5°C), <75% relative humidity
Temperature coefficient 0.1×(specified accuracy) per °F/°C. (32 to 64°F (0 to 18°C), 82 to 122°F(28 to 50°C)).
Power Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life 300 hours typical with alkaline.
Accessories One pair test leads, one pair alligator clips, k-type thermocouple, 9V battery (installed), and operating instructions.
Safety UL,CE,Cat III600V,UL61010-1,IEC/EN61010-1.
Temperature
Range -30 to 1000°F (-34 to 538°C)
Resolution 0.1°F/°C
Accuracy ±1°F, 32 to 120°F (0 to 49°C), ±1% + 1.5°F, -4 to 750°F (-20 to 399°C), ±2% + 4°F, -30 to -4°F (-34 to -20°C), ±2% + 4°F, 750 to 1000°F (399 to 538°C)
Sensor type K-type thermocouple
Overload protection 60 VDC or 30 VAC rms
Continuity
Audible indication Less than 40Ω
Response time 500ms
Green LED will be on continuously.
Overload protection 500VDC or AC rms
DC volts
Ranges 400mV, 4000mV, 40V, 400V, 600V
Resolution 0.1mV
Accuracy ±(0.5% rdg + 2 dgt)
Input impedance 3MΩ on V inputs, 10MΩ on mV input
Overload protection 600VDC or AC rms
Transient protection 6kV for 10μ sec
AC volts (50Hz - 500Hz)
Ranges 400mV, 4V, 40V, 400V, 600V
Conversion True RMS (HS36), average (HS35)
Crest factor Less than or equal to 3 (HS36)
Resolution 0.1mV
Accuracy ±(1.2% rdg + 5 dgts) 50Hz ~ 60Hz on 400mV range
±(1.5% rdg + 5 dgts)
±(2% rdg + 5 dgts) on 600V range
Input impedance 3MΩ
Overload protection 600V DC or AC rms
Transient protection 6kV for 10μ sec
DC current
Ranges 400μA, 4000μA
Resolution 0.1μA
Accuracy ±(1.0% rdg + 2 dgt)
Voltage burden 1V, (8V on 4000μA range)
Overload protection 500V DC or AC rms
Resistance
Ranges 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
Resolution 0.1Ω
Accuracy ±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges
±(1.5% rdg + 4 dgts) on 4MΩ range
±(3.0% rdg + 5 dgts) on 40MΩ range
Open circuit volts -0.45VDC typical, (-1.2VDC on 400Ω range)
Overload protection 500VDC or AC rms
Capacitance
Range 400μF
Resolution 0.1μF
Accuracy ±(3% rdg + 5 dgts)
Overload protection 500V DC or AC rms
Frequency
Ranges 4k, 40k, 400k, 4M, 40MHz
Resolution 1Hz
Accuracy ±(0.1% rdg + 3 dgts)
Sensitivity 10Hz ~ 4MHz: > 1Vrms, 4MHz ~ 40MHz: > 2Vrms, <5Vrms
Minimum pulse width > 25ns
Duty cycle limits > 30% and < 70%
Overload protection 500VDC or AC rms

Questions & Answers


There are no questions or answers for this item.