1-866-4 JJSTECH(1-866-455-7832)

Hanna Calibration Check™ pH/ORP/Temperature Benchtop Meter - HI2221-02

Item #:
HI2221-02
Brand:
Hanna Instruments
Hanna Calibration Check™ pH/ORP/Temperature Benchtop Meter - HI2221-02
$594.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Calibration Check™ pH/ORP/Temperature Benchtop Meter - HI2221-02

Hanna Calibration Check™ pH/ORP/Temperature Benchtop Meter - HI2221-02

$594.00

Discontinued


HI2221-02 Calibration Check™ pH/ORP/Temperature Benchtop Meter by Hanna Instruments

A properly manufactured and maintained pH electrode will retain its measuring integrity for a long time. As a result of many factors such as age, poor maintenance or improper handling, any electrode in time will lose its integrity.

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration.

A dirty electrode or wrong calibration approach can contribute to buffer solution contamination. A contaminated buffer solution can present a major problem during calibration due to the fact that it is considered the only reference.

The HI 2221 is a pH benchtop meter featuring our exclusive Calibration Check™ diagnostics for both pH?electrodes and buffer solutions during calibration. This instrument compares the characteristics of the pH electrode from one calibration to the next. In the case of large variances in the electrode condition, it alerts the user that the electrode needs to be properly cleaned prior to calibration and measuring.

The second feature is to detect if the calibration buffer solution is contaminated. After calibration, the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.

This instrument can measure using ORP electrodes (pH channel input), due to it’s capability to measure mV with a resolution up to 0.1 mV.

This meter also features five point calibration with seven standard buffers, Automatic Temperature Compensation and GLP capabilities that allow for the storage and retrieval of all data regarding pH. With a built-in logging function, measurements are stored in non volatile memory and can be transferred to a PC through the USB port.

  • pH Calibration Check™
  • On-screen electrode condition and response time
  • Up to five point calibration with seven standard buffers
  • Diagnostic alerts through icons
  • Automatic Temperature Compensation
  • GLP features
  • PC interface via USB

Order Information:

HI 2221-01 (115V) and HI 2221-02 (230V) and are supplied with HI 1131B pH electrode, HI 7662 temperature probe, HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 700661 cleaning solution sachet, HI 7071S electrolyte solution (30 mL), 12 VDC adapter and instructions.

pH Range – 2.00 to 16.00 pH
mV Range ± 699.9 mV; ± 2000 mV
Temperature Range – 20.0 to 120.0 °C
pH Resolution 0.01 pH
mV Resolution 0.1 mV (± 699.9 mV); 1 mV (± 2000 mV)
Temperature Resolution 0.1 °C
pH Accuracy ± 0.01 pH
mV Accuracy ± 0.2 mV (± 699.9 mV); ± 1 mV (± 2000 mV)
Temperature Accuracy ± 0.2 °C (excluding probe error)
pH Calibration Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
Temperature Compensation Manual or automatic from -20 to 120°C
Temperature Probe HI 1131P glass body, single junction, refillable with BNC connection and 1 m (3.3') Cable HI 7662 stainless steel probe
PC Connection USB
Data Logging 100 points
Dimensions 235 x 222 x 109 mm (9.2 x 8.7 x 4.3")
Weight 1.3 kg (2.9 lb.)

Questions & Answers


There are no questions or answers for this item.