1-866-4 JJSTECH(1-866-455-7832)

Hanna Hydrazine Portable Photometer - HI96704

Item #:
HI96704
Brand:
Hanna Instruments
Hanna Hydrazine Portable Photometer - HI96704
$267.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Hydrazine Portable Photometer - HI96704

Hanna Hydrazine Portable Photometer - HI96704

$267.00

Discontinued


HI96704 Hydrazine Portable Photometer by Hanna Instruments

Hydrazine is a liquid chemical substance normally used in high pressure heating plants because of its properties as an oxygen inhibitor. It is added to avoid scaling and corrosion in the plant itself. Hydrazine reacts with dissolved oxygen to yield nitrogen and water, so that hydrazine has the advantage over the sulfite treatment because it does not produce any dissolved solids in the boiled water. Hydrazine is also used in tanks because it controls the growth of bacteria. Other hydrazine uses include:

  • oxygen scavenger for water boiler feed and heating systems to prevent corrosion damage
  • energy source in fuel elements
  • reducing agent for the recovery of metals (copper, nickel and others)
  • intermediate in insecticides, herbicides, explosives, plant growth regulators, pharmaceuticals, dyes, flame-retardants, polymerization catalysts and other chemical products
  • component of photo development

The HI 96704 meter measures the hydrazine content in water samples. The method is an adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88 for natural and treated water.

  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features

Order Information:

HI 96704 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96704C includes HI 96704 photometer, sample cuvettes with caps (2 ea.), 9V battery, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.

Range 0 to 400 µg/L
Resolution 1 µg/L
Accuracy ±3% F.S.
Light Source light emitting diode
Light Detection silicon photocell with narrow band interference filter @ 466 nm
Battery Type / Life 9V / approx. 40 hours of continuous use;
auto-off after 10 minutes of non use
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight 360 g (12.7 oz.)
Method adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88 for natural and treated water

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.