1-866-4 JJSTECH(1-866-455-7832)

Hanna Free & Total Chlorine Portable Photometer - HI96724

Item #:
HI96724
Brand:
Hanna Instruments
Hanna Free & Total Chlorine Portable Photometer - HI96724
$288.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Free & Total Chlorine Portable Photometer - HI96724

Hanna Free & Total Chlorine Portable Photometer - HI96724

$288.00

Discontinued


HI96724 Free & Total Chlorine Portable Photometer by Hanna Instruments

The HI 96724 measures the free and total chlorine content in water samples in the 0.00 to 5.00 mg/L (ppm) range. The method is an adaptation of the USEPA Method 330.5 for wastewater, and Standard Method 4500-CL G for drinking water.

The HI 96724 incorporates an advanced optical system based on a special tungsten lamp and a narrow band interference filter that allows the most accurate and repeatable readings. The instrument is factory calibrated and the electronic and optical design minimizes the need of frequent calibration.

The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.

The cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both the measurement and calibration (zeroing) cuvettes, are optically identical to provide the same measuring conditions.

This photometer has been designed to be used with liquid reagents. Free and total chlorine parameters can be switched between depending on procedure and reagents.

  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features

Order Information:

HI 96724 is supplied with sample cuvettes (3) with caps, 9V battery and instruction manual.
HI 96724C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.

Range 0.00 to 5.00 mg/L of Cl2 (Free or Total)
Resolution 0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L
Accuracy ±0.03 mg/L ±3% of reading @ 25°C
Light Source tungsten lamp
Light Detector silicon photocell with narrow band interference filter @ 525 nm
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply (1) 9V battery
Auto-off After 10 minutes of non-use in measuring mode; after 1 hour of non-use in calibration mode
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight 360 g (12.7 oz.)
Method Adaptation of the USEPA method 330.5 and Standard Method 4500-CL G

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.