1-866-4 JJSTECH(1-866-455-7832)

Hanna Total Chlorine, Ultra High Range, Portable Photometer - HI96771

Item #:
HI96771
Brand:
Hanna Instruments
Hanna Total Chlorine, Ultra High Range, Portable Photometer - HI96771
$267.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Total Chlorine, Ultra High Range, Portable Photometer - HI96771

Hanna Total Chlorine, Ultra High Range, Portable Photometer - HI96771

$267.00

Discontinued


HI96771 Total Chlorine, Ultra High Range, Portable Photometer by Hanna Instruments

HI 96771 has been developed to check chlorine dosing in disinfection processes with ultra high concentrations of chlorine. Thanks to the extended range from 0 to 500 mg/L (ppm), it is ideal for the food industry, such as in fruit and vegetable washing.

The HI 96771 meter measures the free chlorine (Cl2) from 0- 5 ppm content in water nd total chlorine in the ultra high range 0-500 ppm. The methods are an adaptation of Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-Cl.

The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit a cuvette with a larger neck making it easier to add both sample and reagents. The cuvette is made from special optical glass to obtain best results.

  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features

Order Information:

HI 96771 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96771C includes HI 96771 photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.

Range Free Chlorine: 0.00 to 5.00 mg/L
Chlorine UHR: 0 to 500 mg/L
Resolution Free Chlorine: 0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L;
Chlorine UHR: 1 mg/L from 0 to 200 mg/L; 10 mg/L above 200 mg/L
Accuracy Free Chlorine: ±0.03 mg/L ±3% of reading @ 25°C;
Chlorine UHR: ±3 mg/L ±3% of reading @ 25°C
Light Source Tungsten lamp
Light Detector silicon photocell with narrow band interference filter @ 466 nm
Power Supply 9V battery
Auto-off After 10 minutes of non-use in measurement mode; After 1 hour of non-use in calibration mode; with last reading reminder.
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight 360 g (12.7 oz.)
Method Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-Cl.

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.