1-866-4 JJSTECH(1-866-455-7832)

Hanna Digital Refractometer for Ethylene Glycol Analysis - HI96831

Item #:
HI96831
Brand:
Hanna Instruments
Hanna Digital Refractometer for Ethylene Glycol Analysis - HI96831
$257.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Digital Refractometer for Ethylene Glycol Analysis - HI96831

Hanna Digital Refractometer for Ethylene Glycol Analysis - HI96831

$257.00

Discontinued


HI96831 Digital Refractometer for Ethylene Glycol Analysis by Hanna Instruments

The HI 96831 Ethylene Glycol Digital Refractometer is a rugged, portable, water resistant device that utilizes the measurement of refractive index to determine the percent volume and freezing point of ethylene glycol based solutions.

This digital refractometer eliminates the uncertainty associated with mechanical refractometers. HI 96831 samples are measured after a simple user calibration with distilled or deionized water. Within seconds, the refractive index and temperature are measured and converted into one of two measurement units; % volume or freezing point. These meters use internationally recognized references for unit conversion and temperature compensation for glycol solutions (e.g. CRC Handbook of Chemistry and Physics, 87th Edition).

  • The dual-level LCD displays measurement and temperature readings simultaneously
  • Automatic Temperature Compensation for accurate measurements
  • Easy measurement; place a few drops of the sample in the well and press the READ key
  • BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.
  • IP65 water protection; built to perform under harsh laboratory and field conditions.
  • Quick, accurate results, readings are displayed in approximately 1.5 seconds.
  • Single point calibration with distilled or deionized water
  • Small sample size, can be as small as 2 metric drops.
  • Automatic shut-off after three minutes of non-use
  • Stainless steel sample well, easy to clean and corrosion resistant
  • ABS thermoplastic casing

Order Information:

HI 96831 is supplied with battery and instruction manual.

% Volume Range 0 to 100 %
Freezing Point Range 0 to -50 °C (32 to -58 °F)
Temperature Range 0 to 80 °C (32 to 176 °F)
% Volume Resolution 0.1 %
Freezing Point Resolution 0.1 °C (0.1 °F)
Temperature Resolution 0.1 °C (0.1 °F)
% Volume Accuracy (@20°C) ±0.2 %
Freezing Point Accuracy (@20°C) ±0.5 °C (±1.0 °F)
Temperature Accuracy (@20°C) ±0.3 °C (±0.5 °F)
Temperature Compensation automatic between 0 and 40°C (32 to 104°F)
Measurement Time approximately 1.5 seconds
Minimum Sample Volume 100 µL (to cover prism totally)
Light Source yellow LED
Sample Cell stainless steel ring and flint glass prism
Auto-off after three minutes of non-use
Enclosure Rating IP 65
Battery Type / Battery Life 9V / approximately 5000 readings
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
Weight 420 g (14.8 oz.)

Datasheets & User Manuals

Questions & Answers