1-866-4 JJSTECH(1-866-455-7832)

Hanna pH/TDS/Temperature Monitor with with backlit LCDs; TDS factor 0.7, 230V - HI981504/7-01

Item #:
HI981504-7-01
Brand:
Hanna Instruments
Hanna pH/TDS/Temperature Monitor with with backlit LCDs; TDS factor 0.7, 230V - HI981504/7-01
$263.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna pH/TDS/Temperature Monitor with with backlit LCDs; TDS factor 0.7, 230V - HI981504/7-01

Hanna pH/TDS/Temperature Monitor with with backlit LCDs; TDS factor 0.7, 230V - HI981504/7-01

$263.00

Discontinued


HI981504/7-01 pH/TDS/Temperature Monitor with with backlit LCDs; TDS factor 0.5, 115V by Hanna Instruments

Set-up is simple. Install the HI 981504 near the sample to be tested, plug the indicator in and immerse the probes. pH, TDS and temperature measurements will be simultaneously displayed on three backlit LCDs.

Users can easily select the temperature unit (°C or °F) on the back panel.

The HI 1286 gel-filled pH electrode is provided with a waterproof sleeve to protect the BNC connector. The unique design of the electrode provides longer life in aggressive solutions. The HI 7634 TDS probe is easy to clean and requires little maintenance. Measurements are accurate and the meter can be calibrated at one or two points for pH and at a single point for TDS. Temperature is factory calibrated.

  • Simultaneous display of pH, TDS and temperature
  • Continuous measurements
  • Measure in °C or °F
  • Three, backlit displays

Order Information:

HI 981504/5-01 (115V) and HI 981504/5-02 (230V) are supplied with HI 1286 pH electrode, HI 7634 TDS probe (fixed), temperature probe (fixed), HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 70032 1382 ppm calibration solution sachet, HI 700661 electrode cleaning solution sachet (2), screwdriver, 12 VDC adapter and instructions.

HI 981504/7-01 (115V) and HI 981504/7-02 (230V) are supplied with HI 1286 pH electrode, HI 7634 TDS probe (fixed), temperature probe (fixed), HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 70442 1500 ppm calibration solution sachet, HI 700661 electrode cleaning solution sachet (2), screwdriver, 12 VDC adapter and instructions.

pH Range 0.0 to 14.0 pH
TDS Range 0 to 1990 ppm
Temperature Range -10.0 to 60.0°C / -14.0 to 140.0°F
pH Resolution 0.1 pH
TDS Resolution 10 ppm
Temperature Resolution 0.1°C / 0.1°F
pH Accuracy @ 20°C ±0.2 pH
TDS Accuracy @ 20°C ±2%
Temperature Accuracy @ 20°C ±0.3°C / ±0.5°F
pH Calibration manual two points through trimmers
TDS Calibration manual one point through trimmer
HI 981504/5 TDS Factor 0.5
HI 981504/7 TDS Factor 0.7
pH Probes HI 1286 PEI body pH electrode with 2 m (6.6’) cable (included)
TDS Probes HI 7634 TDS probe (fixed)
Temperature Probes stainless steel with 2 m cable (fixed)
Temperature Compensation automatic, 5 to 50°C (41 to 122°F), for TDS readings only
Power Supply 12 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F); 95% RH
Dimensions 160 x 110 x 35 mm (6.3 x 4.3 x 1.4”)
Weight 560 g (1.2 lbs.)

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.