PF3W7 Digital Flow Switch for Water, 3-Color Display, Integrated Display by SMC

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90°C, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time. Further improvements include the addition of 2 screens, incorporating 3-color numerical displays which can also be rotated in both clockwise and counter-clockwise directions, thereby offering even better display visibility during operation. Available as non-grease type and with analogue output if required, the PF3W meets IP 65 enclosure protection standards and is both RoHS and CE compliant.

  • Digital flow switch for water applications
  • Integrated display type
  • Flow rate range: 0.5-4(L/min) ~ 10-100(L/min)
  • 3-color, 2-screen display
  • Port sizes: 3/8, 1/2, 3/4, 1

Product contains:

  • 3-Color Digital Flow SWITCH for Water
  • 21 (50 to 250 L/min)
  • N (NPT)
  • 12 (1 1/4)
  • F (OUT1: PNP; OUT2: Analog 4 to 20 mA)
  • T (Temperature Sensor)
  • Lead Wire w/M8 Connector, 3m
  • F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal: Temp: °F)
Specifications of body (Metal attachment)
Model
PF3W704
PF3W720
PF3W740
PF3W711
PF3W721
Applicable fluid
Water and ethylene glycol solution with a viscosity of 3mPa•s (3 cP) or less *1
Detection method
Karman vortex
Rated flow range
0.5 to 4 L/min
2 to 16 L/min
5 to 40 L/min
10 to 100 L/min
50 to 250 L/min
Display flow range
0.35 to 5.50 L/min (Displays 0.00 when the value is below 0.35 L/min)
1.7 to 22.0 L/min (Displays 0.0 when the value is below 1.7 L/min)
3.5 to 55.0 L/min (Displays 0.0 when the value is below 3.5 L/min)
7 to 140 L/min (Displays 0 when the value is below 7 L/min)
20 to 350 L/min (Displays 0 when the value is below 20 L/min)
Switch point range
0.35 to 5.50 L/min
1.7 to 22.0 L/min
3.5 to 55.0 L/min
7 to 140 L/min
20 to 350 L/min
Min. setting unit
0.01 L/min
0.1 L/min
1 L/min
2 L/min
Conversion of accumulated pulse (Pulse width = 50 ms)
0.05 L/pulse
0.1 L/pulse
0.5 L/pulse
1 L/pulse
2 L/pulse
Fluid temperature
0 to 90 °C (No freezing and condensation)
0 to 70 °C (No freezing and condensation)
Display unit
L/min for real-time flow and L for accumulated flow
Accuracy
±3%F.S. max. Display and analogue output
Repeatability
±2%F.S. max *2
Temperature characteristics
±5%F.S. max. (25 °C reference)
Operating pressure range *3
Refer to graph of operating pressure and proof pressure
Proof pressure *3
Refer to graph of operating pressure and proof pressure
Pressure loss
Refer to graph of pressure loss
Accumulated flow range *4
99999999.9 L
999999999 L
By 0.1 L
By 0.5 L
By 1 L
Switch output  
NPN or PNP open collector output
Max. load current
80 mA
Max. applied voltage
28 VDC
Internal voltage drop
NPN: 1 V max. (at 80 mA load current)
PNP: 1.5 V max. (at 80 mA load current)
Response time *2 *5
0.5 s/1 s/2 s
Output protection
Short circuit protection
Output mode Flow
Selects one of the output (hysteresis or window comparator mode), the output for the accumulated flow and the accumulated pulse output.
Temp
Selects the output for fluid temperature (hysteresis mode or window comparator mode).
Analogue output Response time *6
0.5 s/1 s/2 s
Voltage output
Output voltage: 1 to 5 V
Output impedance: 1 kΩ
Current output
Output current: 4 to 20 mA
Maximum load impedance: 300 Ω for 12 VDC, 600 Ω for 24 VDC
Hysteresis
Variable
External input
Voltage free input of 0.4 V or less (reed or solid state type) for 30 ms or longer
Display method
2-screen display (Main screen: 4-digit, 7-segment, 2-colour; red/green, Sub screen: 6-digit, 11-segment, White)
Display updating frequency 5 times/sec.
Indicator light
Output 1 and 2: Orange
Power supply voltage
12 to 24 VDC ±10%
Current consumption
50 mA max.
Environment Enclosure
IP65
Operating temperature range
0 to 50 °C (No freezing and condensation)
Operating humidity range
Operation, Storage: 35 to 85%R.H. (No condensation)
Withstand voltage *7
1000 VAC, for 1 minute between the terminals and housing
Insulation resistance
50 MΩ min. (with 500 VDC) between the terminals and housing
Standards and regulations
CE marking, UL (CSA), RoHS
Material of wetted part
PPS, SUS304, FKM, SCS13
PPS, SUS304, FKM
Grease free
Piping port size *8
3/8
3/8, 1/2
1/2, 3/4
3/4, 1
11/4, 11/2
Weight Flow switch only
210 g
260 g
410 g
720 g
890 g
With temperature sensor
285 g
335 g
530 g
860 g
1075 g
With flow adjustment valve
310 g
360 g
610 g
-
-
With temperature sensor and flow adjustment valve
385 g
435 g
730 g
-
-
With lead wire
+85 g

Specifications of temperature sensor:
Items
Specifications
Rated temperature range
0 to 100 °C *1
Setting/display temperature range
-10 to 110 °C
Min. setting/display unit
1 °C
Display unit
°C
Display accuracy
±2 °C
Analogue output accuracy
±3%F.S.
Response time
7 s *2
Ambient temperature characteristics
±5%F.S.

Specifications of body (Vinyl chloride piping):
Model
PF3W711
PF3W721
Applicable fluid
Water and ethylene glycol solution with a viscosity of 3mPas(3 cP) or less *1
Detection method
Karman vortex
Rated flow range
10 to 100 L/min
30 to 350 L/min
Display flow range
7 to 140 L/min (Displays 0 when the value is below 7 L/min)
20 to 350 L/min (Displays 0 when the value is below 20 L/min)
Switch point range
7 to 140 L/min
20 to 350 L/min
Min. setting unit
1 L/min
2 L/min
Conversion of accumulated pulse (Pulse width = 50ms)
1 L/pulse
Fluid temperature
0 to 70 °C (No freezing and condensation)
Display unit
L/min for real-time flow and L for accumulated flow
Accuracy
±3%F.S. max. Display and analogue output
Repeatability
±2%F.S. max. *2
Temperature characteristics
±5%F.S. max. (25 °C reference)
Operating pressure range *3
Refer to graph of operating pressure and proof pressure
Proof pressure *3
Refer to graph of operating pressure and proof pressure
Pressure loss
Refer to graph of pressure loss
Accumulated flow range *4
999999999 L
By 1 L
Switch output  
NPN or PNP open collector output
Max. load current
80 mA
Max. applied voltage
28 VDC
Internal voltage drop
NPN: 1 V max. (at 80 mA load current)
PNP: 1.5 V max. (at 80 mA load current)
Response time *2 *5
0.5 s/1 s/2 s
Output protection
Short circuit protection
Output mode Flow
Selects one of the output (hysteresis or window comparator mode), the output for the accumulated flow and the accumulated pulse output.
emp.
Selects the output for fluid temperature (hysteresis or window comparator mode).
Analogue output Response time *6
0.5 s/1 s/2 s
Voltage output
Output voltage: 1 to 5 V, Output impedance: 1 kΩ
Current output
Output current: 4 to 20 mA
Maximum load impedance: 300 Ω for 12 VDC, 600 Ω for 24 VDC
Hysteresis
Variable
External input
Voltage free input of 0.4 V or less (reed or solid state type) for 30 ms or longer
Display method
2-screen display (Main screen: 4-digit, 7-segment, 2-colour; red/green, Sub screen: 6-digit, 11-segment, White)
Display updating frequency 5 times/sec.
Indicator light
Output 1 and 2: Orange
Power supply voltage
12 to 24 VDC ±10%
Current consumption
50 mA max.
Environment Enclosure
IP65
Operating temperature range
0 to 50 °C (No freezing and condensation)
Operating humidity range
Operation, Storage: 35 to 85%R.H. (No condensation)
Withstand voltage
1000 VAC, for 1 minute between the terminals and housing
Insulation resistance
50 MΩ min. (with 500VDC) between the terminals and housing
Standards and regulations
CE marking, UL (CSA), RoHS
Material of wetted part
PPS, FKM, CPVC
Grease free
Piping port size *7
25 A
30 A
Weight Without lead wire
285 g
340 g
With lead wire
370 g
425 g

Flow specification of the specified order (flow unit: gal):
Model
PF3W704
PF3W720
PF3W740
PF3W711
PF3W721
Rated flow range
0.13 to 1.06 gal/min
0.53 to 4.23 gal/min
1.3 to 10.6 gal/min
2.6 to 26.4 gal/min
13 to 66 gal/min
Instantaneous flow Display flow range
0.09 to 1.45 gal/min (Flow under 0.09L/min is displayed as "0.00".)
0.45 to 5.81 gal/min (Flow under 0.45 L/min is displayed as "0.00".)
0.9 to 14.5 gal/min (Flow under 0.9 L/min is displayed as "0.0".)
1.8 to 37.0 gal/min (Flow under 1.8 L/min is displayed as "0.0".)
5 to 92 gal/min (Flow under 5 L/min is displayed as "0".)
Setting flow range
0.09 to 1.45 gal/min
0.45 to 5.81 gal/min
0.9 to 14.5 gal/min
1.8 to 37.0 gal/min
5 to 92 gal/min
Min. setting/display unit
0.01 gal/min
0.1 gal/min
1 gal/min
Accumulated flow Setting/display flow unit
99999999.9 gal
999999999 gal
Min. setting/diplay unit
0.1 gal
1 gal
Conversion of accumulated pulse
0.01 gal/pulse
0.05 gal/pulse
0.1 gal/pulse
0.5 gal/pulse
1 gal/pulse

Temperature specification of the specified order (temp. unit: °F):
Rated temperature range * 32 to 212 °F
Setting/display temperature range 14 to 230 °F
Min. setting/display unit 1 o°F

Specifications: lead wire with M8 connector (ZS-40-A)
Items
Specifications
Conductor Nominal cross section area
AWG23
Outside diameter
Approx. 0.72 mm
Insulator Outside diameter
Approx. 1.14 mm
Colours
Brown, White, Black, Blue
Sheath Outer diameter
Φ3.4 mm