1-866-4 JJSTECH(1-866-455-7832)

Seitron Americas Five Gas Industrial Combustion Emissions Analyzer - S6000-5DS

Item #:
SA-S6000-5DS
Brand:
Seitron Americas
$5,995.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Seitron Americas Five Gas Industrial Combustion Emissions Analyzer - S6000-5DS

Seitron Americas Five Gas Industrial Combustion Emissions Analyzer - S6000-5DS

$5,995.00

S6000-5DS Five Gas Industrial Combustion Emissions Analyzer by Seitron Americas

Fast / Easy / Robust / Accurate

  • Built In Printer
  • Up to 6 gas (O2, CO, NO, NH3 , NO2 , CO2, SO2, CxHy (HC), H2, H2S, CH4)
  • Low NOx & Low SOx Capable
  • True NOx (Low NO+NO2) Available
  • Automatic data logging
  • NOx & SOx in one Instrument
  • Diluition pump for CO Auto range up to 100,000 ppm
  • Smartphone Real Time + QRcode App (iOS, Android)
  • Built in Manometer
  • Draft/Pressure included
  • PC Software Included
  • New Ammonia Measurement

Features

  • Draft & Differential Pressure
  • Temperature Measurements
  • Large Color Display
  • 2000 Test Internal Memory
  • Bluetooth Connectivity
  • Long Lasting Rechargeable Battery & AC Charger
  • Gas Sampling Probe & Hose
  • Gas velocity w/optional Pitot tube
  • Longer probes: extension hoses available
MEASUREMENT
SENSOR
RANGE
RESOLUTION
ACCURACY
O2 Long life
Electrochemical
0 .. 25.0% vol
0.1% vol
±0.2% vol
CO sensor w/ Over Range protection NOx filter
Electrochemical
0 .. 500 ppm
0.1ppm
±2 ppm 0 .. 40.0 ppm
±5% measured value 40.1 .. 500.0 ppm
501 .. 8000 ppm
1 ppm
±5% measured value 501 .. 2000 ppm
±10% measured value 2001 .. 8000 ppm
CO2
Calculated
0 .. 99.9% vol
0.1% vol
-
Low NO
Electrochemical
0 .. 500 ppm
0.1ppm
±2 ppm 0 .. 40.0 ppm
±5% measured value 40.1 .. 500.0 ppm
Standard NO
501 .. 5000 ppm
1 ppm
±5% measured value 501 .. 5000 ppm
Low NO2
Electrochemical
0 .. 500 ppm
0.1ppm
±2 ppm 0 .. 40.0 ppm
±5% measured value 40.1 .. 500.0 ppm
Standard NO2
501 .. 1000 ppm
1 ppm
±5% measured value 501 .. 1000 ppm
Low SO2
Electrochemical
0 .. 500 ppm
0.1ppm
±2 ppm 0 .. 40.0 ppm
±5% measured value 40.1 .. 500.0 ppm
Standard SO2
501 .. 5000 ppm
1 ppm
±5% measured value 501 .. 5000 ppm
NOx
Calculated
-
-
-
NH3
Electrochemical
0 .. 500.0 ppm
0.1 ppm
±10 ppm 0 .. 100.0 ppm
±10% 100.1 .. 500.0 ppm
CxHy (HC)
Pellistor
0 .. 5%
0.01 %
±5% full scale
Air Temperature
Pt100
- 4 to 248 °F
- 20 to 120 °C
33.8 °F
32.2°F (0.1 °C)
33.8 °F
32.2°F (0.1 °C)
Gas Temperature
TcK
- 4 to 2280 °F
- 20 to 1250 °C
33.8 °F
32.2°F (0.1 °C)
33.8 °F
32.2°F (0.1 °C)
Differential temperature
Calculated
- 4 to 2280 °F
- 20 to 1250 °C
32.2°F (0.1 °C)
-
Pressure/Draft
Piezo Resistive
-40.1 .. +80.4 inH2O
0.004 inH2O
±1% measured value -40.1 .. -0.81 inH2O
±0.08 inH2O -0.80 .. +0.80 inH2O
±1% measured value +0.81 .. +80.4 inH2O
Excess air
Calculated
0 .. 850%
1%
-
Efficiency
Calculated
0 .. 100%
0.1%
-
Warranty
2 years on Sensors and 2 years on Analyzer

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.