1-866-4 JJSTECH(1-866-455-7832)

ScichemTech SCT-CL-MAXI Chlorine Controller - SCT-108.005.26

Item #:
SCT-108-005-26
Brand:
ScichemTech
ScichemTech SCT-CL-MAXI Chlorine Controller - SCT-108.005.26
$1,689.50
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
ScichemTech SCT-CL-MAXI Chlorine Controller - SCT-108.005.26

ScichemTech SCT-CL-MAXI Chlorine Controller - SCT-108.005.26

$1,689.50

SCT-108.005.26 SCT-CL-MAXI Chlorine Controller by ScichemTech

Includes:

  • Chlorine sensor
  • Fixation clamps
  • Instruction manual

Features:

  • SCT-CL (Chlorine) MAXI CONTROLLERS are designed with creativeness to get the elegance and produced with proper quality, and meets the specifications for the Water related applications with high level performance
  • SCT-CL (Chlorine) MAXI controllers are an industrial instrument used for online analysis and monitoring.
  • SCT-CL (Chlorine) MAXI CONTROLLERS are made in a attractive pleasant colour with a Large and Clear blue white LCD Display
  • SCT-CL (Chlorine) MAXI CONTROLLERS has Microprocessor based controllers, which gives stable and accurate readings.
  • SCT-CL (Chlorine) MAXI CONTROLLERS has Low power consumption and produces less internal heat.
  • SCT-CL (Chlorine) MAXI CONTROLLER S has an isolated 4-20 mA current output
  • SCT-CL (Chlorine) MAXI CONTROLLERS has a RS 485 communication interface
  • SCT-CL (Chlorine) MAXI CONTROLLERS has an automated sensor cleaning control output.
  • SCT-CL (Chlorine) MAXI CONTROLLERS has diaphragm polagraphic electrodes. The electrode consists of cathode, anode, electrolyte and a layer of gas permeability diaphragm on the cathode. The measured residual chlorine diffuse to the cathode through diaphragm. The proper polarization voltage between the cathode and the anode, which can deoxidize the residual chlorine on the cathode. These chemical actions proportional to the residual chlorine which is in the measured medium. which gives reliable measurements.
  • SCT-CL-(Chlorine) MAXI CONTROLLERS are panel mount type of controllers.
  • SCT-CL-(Chlorine) MAXI CONTROLLERS proved to work continuously in any harsh environmental conditions for the In line measurement and control of accurate CHLORINE value.
  • SCT-CL-(Chlorine) MAXI CONTROLLERS has a major advantage that, no reagents are used. It has the direct measurement and readings
Measuring range 0.00 ~ 19.99mg / L
Resolution 0.01mg /L
Zero point calibration range 2.00mg / L
Slope of the calibration range 20% ~ 180%
Temperature compensation 0 ~ 45°C (automatic or manual)
Relay control range 0.00 to 19.99
Automatic cleaning time 1s ~ 99m59s
Cleaning interval 1 ~ 720min
Output signal 4 ~ 20mA
Sensor type Diaphragm polarographic sensor
Sensor cleaning automatic cleaning control output
Serial communication RS485 communication interface
Environmental conditions temperature 0~50°C
Humidity ≤85%RH
Overall dimension 96x96x120mm (Height x Width x Depth)
Dimension of the hole 92x92mm
Installation method panel-mounted
Power supply AC 220 / 240V 50 / 60Hz

Questions & Answers