1-866-4 JJSTECH(1-866-455-7832)

Oakton DO 700 Meter with Probe and Probe Stand, with NIST Traceable Certificate of Calibration - WD-35415-01

Item #:
WD-35415-01
Brand:
Oakton Instruments
Oakton DO 700 Meter with Probe and Probe Stand, with NIST Traceable Certificate of Calibration - WD-35415-01
$1,600.73
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Oakton DO 700 Meter with Probe and Probe Stand, with NIST Traceable Certificate of Calibration - WD-35415-01

Oakton DO 700 Meter with Probe and Probe Stand, with NIST Traceable Certificate of Calibration - WD-35415-01

$1,600.73

WD-35415-01 DO 700 Meter with Probe and Probe Stand, with NIST Traceable Certificate of Calibration by Oakton

Compact size is ideal for laboratory dissolved oxygen measurement applications

DO 700 meter measures dissolved oxygen in mg/L, ppm, or % saturation with simultaneous temperature display in °F or °C. DO is measured from 0 to 20 mg/L (ppm) or from 0 to 200% saturation to meet the needs of a wide array of applications. Independent 100% and 0% calibration points provide accuracy over the entire range. Measurement accuracy can be increased by manual barometric pressure and salinity compensation - meter automatically calculates offset. Built-in automatic temperature compensation provides greater precision by correcting for temperature variations between 32 to 122°F (0 and 50°C).

Large LCD features annunciators to aid in meter use and troubleshooting. Large display size makes viewing measurements easier. Meter is encased in a compact 6-1/8" L x 6-7/8" W x 2-3/4" housing which takes up a minimum of bench space. Water-resistant membrane keypad and convenient pullout reference guide provide useful features for the lab. Additional features include datalogging capabilities up to 100 points, a built-in electrode stand for convenient measurement, and selectable °F/°C temperature measurement.

  • Large brightly-lit LCD shows allows for easy viewing of measured values
  • Low-maintenance galvanic probe requires no warm-up time
  • Built-in memory stores up to 100 data points
Measures Dissolved oxygen and temperature (ºC or ºF)
% saturation Range 0 to 199.9%; 300%
% saturation Resolution 0.1%/1%
% saturation Accuracy ±0.5 % full scale
mg/l (ppm) Range 0 to 30.0 mg/L
mg/l (ppm) Resolution 0.01 mg/L
mg/l (ppm) Accuracy ±0.5 % full scale
Temperature Range 0.0 to 100.0 ºC / 32.0 to 212.0 C
Temperature Resolution 0.1
Temperature Accuracy ±0.5ºC / ±0.9ºF
Memory Up to 100 data sets
Salinity correction 0 to 50 ppt
Barometric pressure correction 450 to 825 mmHg
Built-in Stand Yes
Waterproof/Dustproof (IP67) No
Power 110/220 VAC, 50/60 Hz

Questions & Answers


There are no questions or answers for this item.