1-866-4 JJSTECH(1-866-455-7832)

Extech 381676 Pen DMM with Non-Contact Voltage Detector

Item #:
EXT-381676
Brand:
Extech
Extech 381676 Pen DMM with Non-Contact Voltage Detector
$44.99
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech 381676 Pen DMM with Non-Contact Voltage Detector

Extech 381676 Pen DMM with Non-Contact Voltage Detector

$44.99

Discontinued


381676 Pen DMM with Non-Contact Voltage Detector by Extech

Features

  • Large 2000 count high contrast LCD display
  • Non-Contact Voltage detection with visible and audible alarm
  • Autoranging with Data Hold, Range Hold, and Maximum Hold features
  • Functions include AC/DC Voltage, Resistance, Continuity and Diode Test
  • Auto Power off to conserve battery life
  • Overload and low battery indication
  • Meets IEC1010-1; CAT III-600V
  • Complete with test lead with alligator clips, two 1.5V AAA batteries, and carrying case

Applications

  • AC live circuit detection
  • Field Service troubleshooting tool for AC/DC circuits
  • R & D and circuit board troubleshooting
  • Digital circuitry testing
General Specifications
Diode Test Forward DC bias Current: 1mA approx.;
Reverse DC bias voltage: 1.5V approx.
Overload protection: 250VDC or ACrms
Continuity Check Audible signal will sound if the resistance is less than 50Ω
Open circuit voltage: 0.5V; Overload protection: 250VDC or AC
Display 2000 count (0 to 1999) LCD
Input Impedance 10MΩ, AC & DC Voltage
Over-range indication 'OL' is displayed
Auto Power Off After 15 minutes (approx.) of inactivity
Polarity Automatic (no indication for positive readings), Minus (-) sign for negative readings
Measurement Rate 2 times per second, nominal
Low Battery Indication Battery symbol is displayed to alert battery replacement
Batteries Two (2) 1.5V 'AAA' batteries
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 2000meters (6560ft) operating
Weight / Size 110g (3.9oz) / 208 x 38 x 29mm (8.2 x 1.5 x 1.1")
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995): EN61010-1 (1995) Overvoltage Category III, Pollution Degree 2.

Range Specifications
Function
Range
Resolution
Accuracy
Non-contact AC Voltage detector (NCV)
50 to 600V
NA
DC Voltage (VDC)
200mV
0.1mV
±(0.7% reading + 2 digits)
2.000V
1mV
20V
0.01V
200V
0.1V
600V
1V
AC Voltage (VAC) (40 – 400Hz)
200mV
0.1V
±(0.8% reading + 3 digits)
2.000V
1mV
20V
0.01V
200V
0.1V
600V
1V
±(1.0% reading + 3 digits)
Resistance (open circuit voltage: 0.25V)
200Ω
0.1Ω
±(1.0% of reading + 3 digits)
2kΩ
2kΩ
±(1.0% of reading + 1 digit)
20kΩ
0.01kΩ
200kΩ
0.1kΩ
2MΩ
0.001MΩ
20MΩ
0.01MΩ
±(1.0% of reading + 5 digits)

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.