EX622 400A Dual Input AC Clamp Meter + NCV + IR Thermometer with Limited NIST by Extech

Features

  • True RMS measurements for accurate AC Voltage and Current measurements
  • Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2)
  • Built-in non-contact Voltage detector with LED alert
  • DC µA multimeter function for HVAC flame rod Current measurements
  • Data Hold plus fast Peak Hold of current surges during motor startup
  • 40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
  • Measures motor capacitors to 40,000µF
  • 1.25" (32mm) jaw opening for conductors up to 500MCM
  • Rugged double molded housing
  • Auto power off with audible alert and disable function
  • Autoranging with manual override
  • Complete with CAT III-600V, double molded test leads, 9V battery, two general purpose Type K bead wire probes and case
  • Built-in non-contact IR Thermometer with laser pointer for locating hot spots
  • 8 to 1 distance to target ratio
General Specifications
Clamp jaw opening 32mm (1.25") approx.
Display Dual 40,000/4,000 count backlit LCD
Non-Contact Voltage 100 to 600VAC
Continuity check Threshold 50Ω; Test current < 0.5mA
Diode test Test current of 0.3mA typical;
Open circuit voltage [ 2.8VDC typical
Low Battery indication Battery symbol is displayed
Over-range indication 'OL' display
Measurement rate 2 readings per second, nominal
Peak detector >1ms
Thermocouple sensor Type K thermocouple required
Fuse 500mA, ceramic fast blow
IR Spectral response 6 to 16µm
IR Emissivity 0.95 fixed
IR distance ratio 8:1
Laser pointer Class 2 laser < 1mW power; Wavelength is 630 to 670nm
Input Impedance 10MΩ (VDC and VAC)
AC bandwidth 50 to 400Hz (AAC and VAC)
AC response True rms (AAC and VAC)
Crest Factor 3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60Hz and 5% to 100% of range)
Operating Temperature 5°C to 40°C (41°F to 104°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 2000meters (7000ft) maximum.
Battery One (1) 9V Battery (NEDA 1604)
Auto power OFF After approx. 30 minutes, with disable
Dimensions & Weight 241x96x44.5mm (9.5x3.8x1.75"); 386g (13.6 oz)
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V and Category II 1000V, Pollution Degree 2.
Approvals CE
Patent notice U.S. Patent 7163336

Range Specifications
Function Range Resolution Accuracy (% of reading + digits)
AC Current
50/60 Hz
True RMS
400.0 AAC 0.1A ±(1.5% + 5 digits)
40.00 AAC 0.01A
AC/DC μA Current 400.00μA 0.01μA DC: ±(1.0% + 2 digits)
AC: ±(1.5% + 2 digits)
4000.0μA 0.1μA
AC Voltage
50/60 Hz
True RMS
400.0 mVAC 0.1mV ±(1.0% + 20 digits)
4.000 VAC 0.001V ±(2.0% + 5 digits)
40.00 VAC 0.01V
400.0 VAC 0.1V
600 VAC 1V
DC Voltage 400.00 mVDC 0.01mV ±(0.1% + 6 digits)
4.0000 VDC 0.0001V
40.000 VDC 0.001V
400.00 VDC 0.01V
600.0 VDC 0.1V ±(1.0% + 2 digits)
Resistance 400.00Ω 0.01Ω ±(0.8% + 20 digits)
4.0000kΩ 0.0001kΩ ±(0.8% + 4 digits)
40.000kΩ 0.001kΩ
400.00kΩ 0.01kΩ
4.0000MΩ 0.0001MΩ
40.000MΩ 0.001MΩ ±(2.5% + 10 digits)
Capacitance 400.00nF 0.01nF ±(5.0% + 40 digits)
4000.0nF 0.1nF ±(3.0% + 10 digits)
400.00µF 0.01µF ±(3.5% + 10 digits)
4000.0µF 0.1µF ±(5.0% + 10 digits)
40.000mF 0.001mF
Frequency (clamp) 400.00Hz 0.01Hz ±(1.0% + 3 digits)
Sensitivity: 5Arms minimum
Frequency
(test leads)
40.000Hz 0.001Hz ±(0.3% + 3 digits)
400.00Hz 0.01Hz ±(0.3% + 2 digits)
4000.0Hz 0.1Hz
40.000kHz 0.001kHz
400.00kHz 0.01kHz
4000.0kHz 0.1kHz
40.000MHz 0.001MHz
100.00MHz 0.01MHz Not specified
Sensitivity: 5 to 5kHz; 0.8Vrms min., 5kHz to 150kHz; 5Vrms min
Duty Cycle 0.5% to 99.0% 0.1% ±(1.2% + 2 digits)
Pulse width: 100μs to 100ms, Frequency: 5Hz to 150kHz
Temperature Type K -58 to -4°F
-50 to -19°C
0.1° <1000°
1° >1000°
± 7°C/13°F
-4 to 31°F
-20 to -1°C
±(1.0% + 1°C/2°F)
32°F
0°C
±1°C/2°F
33 to 211°F
1 to 100°C
±(1.0% + 1°C/2°F)
212 to 718°F
101 to 399°C
±(1.5% + 2°C/3°F)
719 to 1832°F
400 to 1000°C
±(2.5% + 4°C/7°F)
Specification does not include probe accuracy
Temperature IR -58 to -4°F
-50 to -20°C
0.1° ± 5°C/9°F
-4 to 31°F
-20 to -1°C
±2% of reading or ±2°C/4°F whichever is greater
32°F
0°C
±1°C/2°F
33 to 518°F
1 to 270°C
±2% of reading or ±2°C/3°F whichever is greater

Datasheets & User Manuals