1-866-4 JJSTECH(1-866-455-7832)

Extech EX710 800A AC Clamp Meter with NIST

Item #:
EXT-EX710-NIST
Brand:
Extech
Extech EX710 800A AC Clamp Meter with NIST
$164.99
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech EX710 800A AC Clamp Meter with NIST

Extech EX710 800A AC Clamp Meter with NIST

$164.99

Discontinued


EX710 800A AC Clamp Meter with NIST by Extech

Features

  • Models with AC/DC Current, AC/DC Voltage, Resistance, Frequency, Capacitance, Temperature, Diode, and Continuity
  • True RMS Models (EX720, EX730)
  • Peak function captures inrush currents and voltage transients
  • Data Hold "freezes" data in display
  • 1.2" (30mm) circular jaw opening for large cables (500MCM)
  • Auto power off
  • Complete with test leads, 9V battery, general purpose Type K bead wire probe and belt holster
  • AC Current

Includes

  • Test leads
  • 9V battery
  • Belt holster
  • General purpose Type K bead wire probe (EX720/EX730 only)
General Specifications
Clamp jaw opening 30mm (1.2") approx.
Display 3-3/4 digits (4000 counts) backlit LCD
Continuity check Threshold 40Ω; Test current < 0.5mA
Diode test Test current of 0.3mA typical;
Open circuit voltage < 3VDC typical
Low Battery indication 'BAT' is displayed
Over-range indication 'OL' displayed
Measurement rate 2 readings per second, nominal
PEAK Captures peaks >1ms
Input Impedance 10MΩ (VDC and VAC)
AC bandwidth 50 to 400Hz (AAC and VAC)
Operating Temperature 5°C to 40°C (41°F to 104°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 2000meters (7000ft) maximum.
Battery One (1) 9V Battery
Auto power OFF After approx. 25 minutes
Dimensions & Weight 229 x 80 x 49mm (9.0 x 3.1 x 2.0"); 303g (10.7 oz).
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V and Category II 1000V, Pollution Degree 2.

Range Specifications
Function
Range & Resolution
Accuracy (% of reading + digits)
AC Current
50/60 Hz
True RMS
40.00A AC
± (2.8% + 10d)
400.0A AC
± (2.8% + 8d)
800A AC
± (3.0% + 8d)
AC Voltage
50/60Hz True RMS
400.0mV AC
± (1.5% + 10d)
4.000V AC
± (1.8% + 8d)
40.00V AC
400.0V AC
600V AC
± (2.5% + 8d)
DC Voltage
400.0mV DC
± (0.8% + 2d)
4.000V DC
± (1.5% + 2d)
40.00V DC
400.0V DC
600V DC
± (2.0% + 2d)
Resistance
400.0Ω
± (1.0% + 4d)
4.000kΩ
± (1.5% + 2d)
40.00kΩ
400.0kΩ
4.000MΩ
± (2.5% + 3d)
40.00MΩ
± (3.5% + 5d)
Capacitance
4.000nF
± (5.0% + 30d)
40.00nF
± (5.0% + 20d)
400.0nF
± (3.0% + 5d)
4.000µF
40.00µF
400.0µF
± (4.0% + 10d)
4.000mF
± (10% + 10d)
40.00mF
unspecified
Frequency
4.000kHz
± (1.5% + 2d)
Sensitivity: 100V (<50Hz); 50V (50 to 400Hz); 5V (401 to 4000Hz)

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.