1-866-4 JJSTECH(1-866-455-7832)

Fieldpiece 400A Amp Clamp Accessory Head - ACH4

Item #:
FP-ACH4
Brand:
Fieldpiece
Fieldpiece 400A Amp Clamp Accessory Head - ACH4
$65.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Fieldpiece 400A Amp Clamp Accessory Head - ACH4

Fieldpiece 400A Amp Clamp Accessory Head - ACH4

$65.00

Discontinued


ACH4 400A Amp Clamp Accessory Head by Fieldpiece

The ACH4 current clamp is a small size accessory head for quickly reading up to 400 AC amps. The claw feature on the clamp makes it easy to quickly pick out the wire you need to measure. Once the current carrying conductor is isolated, the amperage is converted to mVAC for reading directly on the meter. The ACH4 works with the Fieldpiece "Stick" meter, EHDL1 Electronic Handle, EH4W Wireless Handle, DL3 Data Logger, the HG2 and HG3 HVAC Guide® System Analyzers, or any other digital multimeter (with mVAC range) connected by Fieldpiece ADLS2 detachable silicone leads or AHDL1 handle adapter.

Features

  • Connect directly to any Fieldpiece stick meter (shown attached to HS36)
  • Remote the amp clamp for hard to reach areas using our deluxe silicone leads with detachable probe tips (model ADLS2)
  • Angled jaw opens to 1.8 inches and makes singling out a wire fast and easy

Included

  • 400A Amp Clamp Accessory - ACH4
  • Operator's Manual
Current range 1AAC to 400AAC rms
Conversion rate 1AAC to 1mVAC
Frequency 50Hz to 60Hz
Operating temperature 32°F to 122°F
Storage temperature -4°F to 140°F
Temperature coefficient 0.1 x (specified accuracy) per °F. (32°F to 64°F, 82°F to 122°F)
Altitude 6561.7 Feet (2000m).
Resolution 0.1A
Accuracy ±(1.5%rdg + 0.2A), 1 to 20AAC;
±(2.5%rdg + 0.3A), 20 to 100AAC;
±(3.5%rdg + 0.5A), 100 to 400AAC
Maximum conductor diameter 1.18 in. (30mm)
Accessories operator's manual
Safety Designed to meet IE C61010-1 (EN61010- 1) and IEC61010-2-032 (EN61010-2-032), CATIII 300V, class 2 and pollution degree II indoor use comply with CE.

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.