1-866-4 JJSTECH(1-866-455-7832)

Fieldpiece Dual Display Swivel-Head Clamp Meter - SC55

Item #:
FP-SC55
Brand:
Fieldpiece
Fieldpiece Dual Display Swivel-Head Clamp Meter - SC55
$169.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Fieldpiece Dual Display Swivel-Head Clamp Meter - SC55

Fieldpiece Dual Display Swivel-Head Clamp Meter - SC55

$169.00

Discontinued


SC55 Dual Display Swivel-Head Clamp Meter by Fieldpiece

The SC55 Swivel-Head Clamp Meter is specifically designed for HVACR professionals and contains all the functions most relevant to the job. Packed with 13 different test parameters the SC55 clamp meter offers more features and functions than any other meter of its kind on the market. Plus the full 180º swivel head allows you to easily see the display at any angle.

Perfect for those hard to reach wires, the SC55 Swivel-Head Clamp Meter also boasts a rugged design to withstand harsh conditions, has the precision and reliability that Fieldpiece is known for, and is compatible with all Fieldpiece Accessory Heads via your test leads.

  • 180° Swivel Head Clamp to easily view your results at any angle
  • Dual Display to easily view multiple measurements at one time
  • Rugged Construction to withstand harsh conditions
  • Auto Power Off to preserve your battery life when clamp isn't in use
  • Non-Contact Voltage warning via audio and visual alarms
  • Easy Field Calibration with convenient pot location to quickly calibrate K-type thermocouples
  • Auto or Manual Ranging button to conveniently toggle between ranges
  • Hold Function to keep data as long as necessary
  • Select Button to swiftly toggle through measurement options
  • Frequency Measurement without test leads
  • Constant Battery Status so you don't run out of batteries in the middle of a job

Includes

  • SC55 - Swivel Head Clamp Meter
  • ADLS2 - Deluxe Silicone Test Leads
  • ASA2 - Alligator Clip Lead Extensions
  • ATB1 - K-type Thermocouple
  • ANC7 - Large Single Meter Case
  • Velcro Strap
General Specification
Display 5000 count dual display with backlight
Overrange (OL) or (-OL) is displayed
Measurement rate 3.3 times per second, nominal
Zero Automatic
Operating environment 32°F to 122°F (0°C to 50°C) at <70% relative humidity
Storage temperature -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed)
Accuracy Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
Temperature coefficient 0.1 x (specifi ed accuracy) per °C [0°C to 19°C (32°F to 66°F), 28°C to 50° C(82°F to 122°F)]
APO (Auto Power Off) Approx. 30 minutes
Power Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life 200 hours typical alkaline (SC55); 100 hours typical alkaline (SC56)
Low battery indication Battery icon blinks and "LO.bt" is displayed when the battery voltage drops below the operating level
Dimensions 258.3mm(H) x 71.2mm(W) x 42.7mm(D)
Weight Approx. 278g including battery
Overload protection 600 VDC or 600VAC rms unless otherwise stated
Test leads Use the test leads that are supplied with the meter or UL listed test leads rated CATIII 600V or above.
Temperature (°F/°C)
Range -30°F to 932°F, (-35°C to 500°C)
Resolution 0.1°
Accuracy ±(1°F) 32°F to 120°F, ±(1°C) 0°C to 49°C
±(1%+2°F) 32°F to 572°F, ±(1%+1°C) 0°C to 300°C
±(2%+6°F) -30°F to 32°F, ±(2%+3°C) -35°C to 0°C
±(2%+6°F) 572°F to 932°F, ±(2%+3°C) 300°C to 500°C
Sensor type K-type thermocouple
Overload protection 30 VDC or 30VAC rms
Non Contact Voltage (NCV)
AC Voltage Detection Range 24VAC to 600VAC (50-60Hz)
Voltage AC (VAC) (50Hz-500Hz)
Ranges 500mV, 5V, 50V, 500V, 600V
Resolution 0.1mV
Accuracy ±(1.2% + 8) 500mV range (50-60Hz)
±(1.2%+8), 5V, 50V, 500V; ±(1.5% + 8) 600V range
True RMS model SC56 only
Crest factor ≤ 3
Input impedance >100MΩ (500mV), 10MΩ (5V), 9.1MΩ (50V-600V)
MicroAmps DC (μADC)
Ranges 500μA
Resolution 0.1μA
Accuracy ±(1.0% + 2)
Voltage burden 1V
Overload Protection 600VDC or 600VAC rms
Frequency (Hz) through Leads
Ranges 500Hz, 5kHz, 50kHz, 500kHz, 1MHz
Resolution 0.1Hz
Accuracy ±(0.1% + 5)
Sensitivity 10Hz to 1MHz: >3.5Vrms
Duty Cycle (%)
Ranges 5%-95% (40Hz to 20kHz)
PW >10μs
Resolution 0.1%
Accuracy (5V logic) ±(2% + 10)
Capacitance (MFD)
Ranges 5μF, 50μF, 500μF, 5mF
Resolution 1nF
Accuracy ±(3% + 15) 5μF, ±(3% + 5) 50μF to 500μF, ±(5% + 20) 5mF
Overload Protection 600VDC or 600VAC rms
Voltage DC (VDC)
Ranges 500mV, 5V, 50V, 500V, 600V
Resolution 0.1mV
Accuracy ±(0.5% + 2)
Input impedance >100MΩ (500mV), 10MΩ (5V), 9.1MΩ (50V-600V)
Resistance (Ω)
Ranges 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 50MΩ
Resolution 0.1Ω
Accuracy ±(1.0% + 5) 500Ω to 500kΩ, ±(1.5% + 5) 5MΩ, ±(3.0% + 5) 50MΩ
Overload Protection 600VDC/VAC rms
Continuity
Range 500Ω
Resolution 0.1Ω
Response time 100ms
Audible beep <30Ω
Overload Protection 600VDC/VACrms
Diode Test
Test current 0.8mA (Approx.)
Accuracy ±(1.5% + 5)
Overload Protection 600VDC/VACrms

Questions & Answers