1-866-4 JJSTECH(1-866-455-7832)

Honeywell Analytics Sensepoint Detector with Junction Box, 0-10ppm Nitrogen Dioxide - SPSTAXN1

Item #:
SPSTAXN1
Brand:
Honeywell Analytics
Honeywell Analytics Sensepoint Detector with Junction Box, 0-10ppm Nitrogen Dioxide - SPSTAXN1
$989.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Honeywell Analytics Sensepoint Detector with Junction Box, 0-10ppm Nitrogen Dioxide - SPSTAXN1

Honeywell Analytics Sensepoint Detector with Junction Box, 0-10ppm Nitrogen Dioxide - SPSTAXN1

$989.00

SPSTAXN1 Sensepoint Detector with Junction Box, 0-10ppm Nitrogen Dioxide by Honeywell Analytics

The Sensepoint range of flammable, toxic and Oxygen gas detectors offers users a cost-effective solution to their gas monitoring needs, in or out of doors and even in potentially explosive atmospheres. Supplied with a pre-wired junction box, this detector can be installed using conduit or armoured cable and glands depending on the specific needs of the application.

Sensepoint flammable and toxic gas detectors are designed for use in potentially explosive atmospheres, and allow for easy access to terminals via the hinged lid of the junction box. Installation should follow national guidelines using suitably approved armoured cable and glands or conduit.

Supplied with an earth continuity plate for increased resistance to the effects of RFI, the junction box offers the installer a choice of 1/2", 3/4" and M20 connection via conduit or armoured cable and Ex e certified cable glands. Terminals are suitable for use with screened 0.5mm2 (20AWG) to 2.5mm2 (14AWG) cross sectional area cable, as needed to ensure minimum operating voltage at the detector, depending upon installed cable length.

Sensepoint flammable, toxic and Oxygen gas detectors are designed for direct connection with the Honeywell Analytics' range of Touchpoint controllers.

One-Stop Shop

  • Flammable, toxic and Oxygen versions available
  • Suitable for indoor or outdoor use
  • IP65 as standard

Proven Sensor Technology

  • Surecell™ electrochemical sensors
  • Poison resistant catalytic bead
  • Fast and reliable
  • Typical 2 to 5 years operational life

ATEX Certified

  • Complies with the latest European standards
  • Hazardous area and performance approvals
  • Can be used for uncertified applications

Easy to Use

  • Factory set operation
  • Simple sensor replacement
  • Minimal training required

Friendly Installation

  • Universal junction box
  • One box, three entries
  • Metric and NPT compatibility
  • Includes earth continuity plate for enhanced protection against RFI

Range of Accessories

  • Weather Housing (IP66)
  • Flow adaptor
  • Collecting cone
General specification
Use Cost-effective, fixed point gas detector for the protection of personnel and plant from flammable, toxic and Oxygen gas hazards
Detectable gases
Gas Measuring range Operating temperature
Ident Name 1 2 3 Min Max
F Flammable 0-100% LEL     -40°C / -40°F 50°C / 122°F
O Oxygen 0-25% VOL     -15°C / 5°F 40°C / 104°F
C Carbon Monoxide 0-200ppm 0-500ppm   -20°C / -4°F 50°C / 122°F
H Hydrogen Sulphide 0-50ppm 0-20ppm 0-100ppm -25°C / -13°F 50°C / 122°F
G Hydrogen 0-1000ppm     -5°C / 23°F 40°C / 104°F
L Chlorine 0-5ppm 0-15ppm   -20°C / -4°F 50°C / 122°F
S Sulphur Dioxide 0-15ppm 0-50ppm   -15°C / 5°F 40°C / 104°F
N Nitrogen Dioxide 0-10ppm     -15°C / 5°F 40°C / 104°F
A Ammonia 0-50ppm 0-1000ppm   -20°C / -4°F 40°C / 104°F
Construction
Electrical Flammable (0-100%LEL)
3 wire mV bridge 2.9-3.5V, 0.7W 200mA constant current
Toxic & Oxygen
2 wire loop powered 4-20mA (plus screen) 16-30Vdc, O.9W
Junction Box
Earth continuity plate BK4 terminal block (4 way) 4 x 0.5mm2 (20AWG) to 2.5mm (14AWG) 1 x M20, 1 x 3/4" NPT, 1 x 1/2" NPT
Material Polyphenylene Sulphide (PPS) Polyphenylene Sulphide (PPS) Fire retardant GFP
Weight 190g 185g (205g Oxygen) 600g
Applicable standards This product complies with the relevant CE standards including: EMC to EN50270, Flammable to EN60079-29-1, Toxic to EN445544 (H2S only)
Environmental
IP rating IP65 standard, IP66 with weather protection in accordance with EN60529:1992
Operating temperature Dependent upon gas type and certification
Operating humidity range Continuous: 20-90% RH (non condensing), Intermittent: 10-99% RH (non condensing)
Operating pressure 90-110kPa
Storage conditions Instrument -40°C to +50°C (-40°F to +122°F)

Questions & Answers